5) Press the on / off button to turn on the unit. Water pump drain hose Fig.6 1 BEFORE USE Dehumidifying and Cooling Operations O OOO - The operating range for cooling operating is 17 C-30 C/63 F-86 F. - If the cooling or dehumidifying operations have been switched off and need switching on again in a short time, allow approximately three minutes for the cooling or dehumidifying operations to resume. -Make sure the water pump drain hose is correctly connected to the unit. Power supply: - Insert the AC Power Plug to a AC socket. - Do not connect the air conditioner to a multiple socket outlet which is also being used for other electrical appliance. - Be sure the power supply is AC 115V~ 60Hz. O OOO 2 COOLING OPERATION (Operating temperature range: 17 C-32 C/63 F-90 F) - Press the "MODE" button several times until the "COOL" indicator light comes on. -Press the "TEMP SETTING" buttons "" or "" to select your desired room temperature. O OOO (17 C-30 C/63 F-86 F) - Press the "FAN SPEED" button to choose the fan speed. O OOO 3 DEHUMIDIFYING OPERATION (Operating temperature range: 13 C-32 C/55 F-90 F) - Press the "MODE" button several times until the "DRY" indicator light comes on. - The fan will run at a fixed speed at this setting. - Keep windows and doors closed for the best dehumidifying effect. - Do not put the duct to window. 4 HEATING OPERATION (Cooling only type without heat feature) O OOO (Operating temperature range:5 C-30 C/41 F-86 F) - Press the "MODE" button several times until the "HEAT" indicator light comes on. -Press the "TEMP SETTING" buttons "" or "" to select your desired room temperature. O OOO (17 C-30 C/63 F-86 F) - Press the "FAN SPEED" button to choose the fan speed. - Do not put the duct to window. 5 FAN OPERATION - Press the "MODE" button several times until the "FAN " indicator light comes on. - Press the "FAN SPEED" button to choose the fan speed. - Do not put the duct to window. 6 TIMER OPERATION Setting the on timer: - Press the "TIMER ON" button when the air conditioner is off. Select the time you need the unit start to operate. - The Operation Paned Window will display "ON" -The starting time is adjustable from 0.00 to 24. Setting the off timer: - Press the "TIMER OFF" button when the air conditioner is on. Select the time you need the unit turn off. The Operation Panel Window will display "OFF". - The turning off time is adjustable from 0.00 to 24. 7 WATER PUMP DRAINAGE - Connect the water pump drain hose to the unit before operate. When the water level of the internal water tank reaches a predetermined level, the water pump will be activated and drain the condensed water outside through the connected drain hose. The maximum delivery lift is 3.5m. (Under this condition, attach the rubber blockage to the back hole to prevent continuous drainage.) 8 CONTINUOUS DRAINAGE - When you plan to leave this unit unused for a long time, remove the rubber blockage form the back hole and attach a section of the continuous drain hose ...
Dieses Handbuch ist für folgende Modelle:Splitgeräte - DOC-091R (1.56 mb)
Splitgeräte - DOC-091R (1.56 mb)
Splitgeräte - DOC-091RH (1.56 mb)
Splitgeräte - DOC-091R (1.56 mb)