Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Amcor, modell AL-10

Hersteller: Amcor
Dateigröße: 460.04 kb
Dateiname: 717adb55-9594-415c-8742-527b11683de4.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Most of this water is used to cool the unit and make it run more efficiently. This is a feature not found in most Portable Air Conditioners. If the unit is operated in VERY HUMID air, water will collect in the container inside the unit. If the Internal Water Container is full, the backlight on the LCD display will flash, the unit will shut off, and it must be drained before it will re-start. How to Drain the Unit Use a Shallow Container or Dish 1. Turn off the unit. 2. Position a flat container or dish under the drain hole. Do not allow the water to drip continuously into the container, as it might easily overflow. 3. Remove the drain knob & rubber plug from the drain hole. The condensed water will drain out automatically. 4. When the container is almost full, replace the rubber plug into the drain hole to stop the water. Empty the container. 5. Repeat steps 2,3 & 4 until all the condensed water is emptied. 6. Once all the condensed water has been removed, replace the rubber plug into the drain hole firmly. The Full Water indicator should be off now. 7. Replace the drain knob. 8. Turn unit on, the unitwill resume working. drain knob 0 rubber plug drain knob v 10 Specifications Model Number AL-I0.000E AL-I0,000EH Cooling Capacity 10,000 BTU/hr 10,000 BTU/hr Heating Capacity N/A 10,000 BTU/hr Power Consumption 660W / 6.0A 660W / 6.0A Humidity Removal Capacity 38 Pts./ Day 38 Pts./Day Recommended room size* Up to 300 sq.ft. Up to 300 sq.ft. Power Supply 1 15V / 60Hz / 1 Phase 1 15V / 60Hz / 1 Phase Compressor Rotary Rotary Refrigerant R-22 R-22 Fan Speed 2 2 Timer 1-12 hours 1-12 hours Temperature Set Range 62°F - 90°F 62°F - 90°F Unit Weight 63 lbs. 66 lbs. Dimensions I5"W x I6"D x 30"H I5"W x I6"D x 30"H Working Temperature Cooling: 62°F to II0°F Cooling: 62°F to II0°F Heating: 4 l°F to 8I°F REMARKS: The cooling capacity of the unit may be affected by the height of the ceiling, quality of insulation, number of windows, etc. 3 Operation Automatic Mode Indicatoi High Fan Speed Indicator Low Fan Speed Indicator Room Temperature Indicator Set Temperature Indicator Pooling Mode Indicator Fan Mode Indicator Heating Mode Indicator (For Models With Heating Options) Timer Operation Indicator Compressor Indicator Temperature Up Selector Temperature Down Selector Fan Speed Selector Timer Selector On/Off (Power) Selector „___________, TimerS 1 Selector Setting Mode/Function Press the MODE button to select the required working mode:Automatic, Cooling, Fan or Heating (Heating is only available for AL-10,000EH).The green indicator illustrating your selected mode lights up. It is recommended to select Cooling or Heating mode and set your desired temperature, as the Auto mode has a preset temperature (please see below) that cannot be changed. The indicators of the functions in progress come on at the same time, e.g. Cool and Lo = Cooling mode with Low fan speed. Auto Mode When this mode is selected, the unit is preset to the following temperature settings and unit will only start to: • Cool when room temperature is higher than 75°F • Heat when room temperature is lower than 68°F (AL-I0,000EH only) If room temperature is between 68°F and 75°F, unit will stay in Fan mode. Again, when in Auto Mode, the temperature settings cannot be changed. Setting the Temperature in Cooling or Heating Mode The display window’s default is to display the ambient room temperature. The green indicator light under RT is on. (RT = Room Temperature) To set your desired temperature, press the Temperature up or down buttons (ranging from 62°F to 90°F). Each press will increase or decrease your set temperature by l°F. When pressing the temperature up or down buttons, the window will change to display your set temperature. At this time, the green indicator will light under ST (Set Temperature). Once the temperature up or down buttons is released, the window will return to displaying the ambient temperature after a second. Note: When unit is in the following modes: Auto, Cool, or Heat - the compressor will cool/heat the room to reach the set temperature. Once the ambient temperature has reached the set temperature, the compressor will stop and unit will run in Fan mode. To conserve energy, the compressor will not start immediately after a couple degrees increase or decrease, but will wait for a 5°F allowance. For example: In Cooling Mode with a set temperature of 70°F When compressor first stops after reaching 70°F, unit will auto-switch to Fan. Compressor will start cooling again when ambient temperature increases to 75°F or above. In Heating Mode with a set temperature of 72°F When compressor first stops after reaching 72°F, unit will auto-switch to Fan. Compressor will start heating again when ambient temperature drops to 67°F or below. In Auto Mode (with preset temperature of 68°F for heat and 75°F for cool) Compressor will start cooling again when ambient temperature reaches abov...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien