|
Anleitung Zusammenfassung
Take care to prevent any bow or bend in the exhaust hose. 1 13 16 2 14 16 4 5 6 15 3a 3b 6 ON/OFF and timer function Turn the control [1] to switch the unit on or off. When the unit is on, LED-1 is on. Timer function Use control [1] to set a working time between 1 and 8 hours. The unit switches off when the set time has run down. Mode selection and speed setting Select with control [2] the required operating mode cooling or fan mode. The corresponding LED (2 or 3) will lit. Select the larger symbol position for high or low fan speed, or low or strong cooling. Thermostat setting Turn control [3] to maintain the temperature level in combination with cooling. Notices: • The compressor has been set so that it starts functioning three minutes after the (re)start of the air conditioner. • The cooling will switch off when the room temperature is lower than the set one. Ventilation will however continue to work on the set level. When the room temperature rises above the selected value, the cooling will work again. Air flow Turn the roller to control the air flow direction of the vertical louvres. Move the air vent directly to adjust the air flow direction of the horizontal louvres. OPERATION GB 3 2 1 1 2 3 4 8 Important: how to wire a 13 amp plug The wires in the mains lead on this appliance are coloured in accordance with the following code: GREEN AND YELLOW – EARTH BLUE – NEUTRAL BROWN – LIVE As the colours may not correspond with the markings identifying the terminals in your plug proceed as follows: The GREEN AND YELLOW wire must be connected to the terminal in the plug which is marked with the letter E or with the earth symbol or coloured green and yellow. The BLUE wire must be connected to the terminal marked N or coloured black. The BROWN wire must be connected to the terminal marked L or coloured red. ELECTRIC CONNECTION GREEN/YELLOW Earth BLUE Neutral BROWN Live FUSE 13 Amp Cord clamp GB STORAGE First of all switch off the unit and pull the plug. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. Filter The single layer screen filter cleans the circulated air. The filter needs to be cleaned regularly with a vacuum cleaner to avoid blocking the air flow. • Push the two clips on the filter housing downward and pull the filter housing forward and out of the unit. • Remove the rear retainer from the housing by gently prising it from the retaining clips. • Insert the screen filter aligning the two cut outs with the clips on the top of the filter housing. • Reverse the procedure to re-fit the housing in the air conditioner. Notice! Never use the air conditioner without filter. See the instructions "Emptying the water container" on page 7. • Drain the condensed water completely. • Clean (or replace) the filter. • Put the unit on a sunny day in fan mode for a couple of hours to ensure that the inside becomes completely dry. • Store the power cable as shown, protect the unit against dust and store in a dry place not accessible for children. Cable storage CLEANING 9 GB Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in loss of warranty and can endanger the user. Problem Cause Solution The unit does not function Check the plug fuse. Check the mains outlet by connecting another appliance Connect to a functioning outlet and switch on Water container indicator is on Empty water container Room temperature outside operating temperature range The unit does not seem to perform In direct sunlight Close curtains Windows or doors open, many people or heat source in room Dirty filter Clean or replace filter Air inlet or air outlet blocked Remove blockage Room temperature lower than selected value Change temperature selection The unit is noisy Unit stands uneven Place on even surface (less vibrations) The compressor does not work Overheat protection probably activated Wait until room temperature lowers TROUBLE SHOOTING Model AMC 7KM-410 AMC 10KM-410 AMC 12KM-410 Cooling capacity measured conform EN 14511 BTU/h 6500 8300 9600 kW 1.9 2.4 2.8 Mains 220–240 V / 50 Hz / 1 phase Power consumption W 690 830 1030 Current A 3.0 3.7 4.5 Dehumidification L/24h 24 28.8 36 Air delivery m3/h 300 350 350 Recommended room size m2 12 18 24 Refrigerant type R410A Compressor rotary Fan speeds 2 Thermostat °C 18 – 32 Timer h 1 – 8 Dimensions (W x H x D) mm 377 x 750 x 400 Weight kg 29 30 32 Subject to modifications without prior notice. Please refer to the rating label for greater precision. TECHNICAL DATA 10 Amcor products have a lower than industry norm failure rate, as we have strict quality control in our factory. However we are not 100% perfect and occasionally units can fail. When they do we have a simple returns procedure. All Amcor products are guaranteed for one-year from date of purchase, on a back to base principle. A copy of our guarantee page is attached. Consumers need to keep the till receipt as proof of purchase. The Am...
Dieses Handbuch ist für folgende Modelle:Splitgeräte - 10KE-410 (1.09 mb)
Splitgeräte - 12KE-410 (1.09 mb)