Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Field Controls, modell CLEARWAVETM WATER CONDITIONER CW-HD-4

Hersteller: Field Controls
Dateigröße: 287.5 kb
Dateiname: 46302600.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


(see Figure 1) For pipe mounting, the wall mount tabs should be removed from the mounting brackets. (see Figure 2) 2. Plug the antennas into each end of the housing, to the appropriate wire wrap connections (e.g. “CW” for clockwise wrapping and “CCW” for counter clockwise wrapping). If longer wires are needed, up to 50 feet of 12Ga stranded wire can be added to the antenna wires with an insulated butt end wire connector or they Page 2 Page 3 can be replaced with 70 feet of 12Ga stranded wire. PROPERLY WRAPPING THE ANTENNAE The antenna wrap around the water pipe on each end of the ClearWave™ (see Figure 1). A minimum of seven fully wrapped coils of the antenna wire, with each coil wrapped tightly against the pipe and pressed snugly against each other is required for best results (see Figure 1A). Each wire coil should be spaced I inch to 2 inches apart. The operation of the ClearWave™ and the antenna installation is not based on direction of water flow, but one antenna MUST be wrapped in a clockwise direction and the other wrapped in an counterclockwise direction. 1. On the right side of the unit wrap the first antenna onto the water pipe by securing the “CW” clockwise antenna to the water pipe next to the ClearWave™ housing with a wire tie. Wrap the right antenna clockwise (over the top of the pipe first), keeping the antenna wire tight against the pipe and the preceding coil. Secure the end of the antenna wire to the water pipe with a wire tie (see Figure 1A). Repeat wrapping the remainder of the antennas onto the pipe alternating the wrap direction (see Figure 1). 2. On left side of the unit wrap the first antenna onto the water pipe by securing the “CCW counter clockwise antenna to the water pipe next to the ClearWave™ housing with a wire tie. Wrap the antenna counter clockwise (Under the bottom of the pipe first), keeping the antenna wire tight against the pipe and the preceding coil. Secure the end of the antenna wire to the water pipe with a wire tie. Repeat wrapping the remainder of the antennas onto the pipe alternating the wrap direction (see Figure 1). 3. When energized, the ClearWave™ by plugging in the power supply, the modulation indicator lights start flashing sequentially indicating that the ClearWave™ is functioning properly. If the indicator lights do not flash sequentially, unplug the power supply, wait one minute then plug in the power supply again. If at any Figure 1 Figure 1A Figure 2 time a functional problem is suspected, unplug the power supply, wait one minute then plug in the power supply again. Page 4 NOTE: The performance of the ClearWave™is not affected by the direction or orientation of the unit. The unit may be mounted to horizontal, vertical, or diagonally. The ClearWave™ can be used effectively on any type of water pipe; galvanized, copper, or plastic. NOTE: The ClearWave™ is designed and tested to cause little or no interference to other communication devices, such as televisions, and most cordless telephones. Install the ClearWave™ at least ten feet from any radio, television, or cordless telephone base unit to eliminate possible interference. MAXIMUM WATER CONDITIONING CAPACITY FOR NOMINAL PIPE DIAMETERS Nominal Pipe Diameter 3 inch 4 inch 6 inch 8 inch # of Units Req. 1 1 1 2 GPM Flow 220 390 877 1630 OPERATION TIMETABLE FOR THE CLEARWAVE™ The following timetable of events should be used to evaluate the operation of the ClearWave™ during the 180-day customer satisfaction period. This is the best way to evaluate the ClearWave™ operation and benefits the ClearWave™ technology can provide for you and your home. Please note testing for changes in hardness with current testing practices will not show you if the ClearWave™ is working. The current practice of determining water hardness is the measurement of the concentration of calcium and magnesium in the water. Since the ClearWave™ does not remove any calcium or magnesium ions from the water, testing the water before and after the installation of the ClearWave™ will not show any change. DAY 1: ........................................ The ClearWave™ action immediately starts to loosen existing scale in both the hot and cold water systems. One should find soap lathers more easily. DAY 5 and onwards: .................. Scale begins to break down and come off water heater elements (immersion heaters) and tanks. Most particles are microscopic and will flow through your water system, but some small particles may be seen in the water coming from the hot water tap. DAY 10 to 16: ............................. It should be noticeably easier to wipe clean ceramic, plastic, glass, and metal surfaces. By now the quantity of bath soap, dish soap, laundry detergent, and laundry softening agents can be reduced. Scale should have loosened on faucet, showerheads and frequently used appliances that boil water (such as coffee makers). DAY 16 and onwards: ................ Scale should continue to loosen from faucet, showerheads, and pipes. With th...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien