Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung APC, modell INROOM SC ACPSC3500

Hersteller: APC
Dateigröße: 1.09 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


6. Slide the flange onto the exhaust vent on the back of the cooling unit. na3421b InRoom SC 60 Hz User Manual Condensate Drain The InRoom SC utilizes evaporative technology, which eliminates the need for a condensate tank. To manage any excess condensation, a drain pan is located in the bottom of the unit. When the drain pan is full, a light will flash on the display and an alarm will sound to alert you. The cooling unit will automatically shut down. Caution: The cooling unit must be turned off and unplugged before draining the condensate. Manual draining 1. When the drain pan is full, move the cooling unit to a drain or place a suitable container under the drain pipe. 2. Remove the plastic cap and rubber plug to allow the condensate to drain. 3. Replace the plug and cap when the drain pan is empty. 4. Return the cooling unit to service. ON/OFF MODE SLEEP FAN TEMP TIME InRoom SC MODETIMER FANSEND SLEEP DRY Hr. MinON/OFF + °F - °F na3356a InRoom SC 60 Hz User Manual Continuous draining Note: Continuous drainage is recommended when the unit is used in DRY mode. Caution: Condensate draining is done by gravity. Do not run a drain hose to a drain that is located above the drain port of the cooling unit. na3393a InRoom SC 60 Hz User Manual Operation Control Panel ON/OFF MODE SLEEPFAN TEMP TIME InRoom SC na3359a Function Button Locations Item Function Description 1 Power control Turn the cooling unit On and Off 2 Mode selection Three mode control settings: Cool, Dehumidify, and Fan. The settings are adjusted by pressing the Mode Control Button. 3 Remote control infrared Receives commands sent from the remote control. receiver 4 Fan speed control Press the Fan Speed Control button to move through the three settings: Low, Medium and High. 5 Display interface LCD user interface displays instructions and functions. 6 Temp .. • Up and down arrow buttons adjust the thermostat. 7 Timer .. • Up and down arrow buttons adjust the timer. 8 Sleep Press the Sleep button to start or stop the Sleep mode. InRoom SC 60 Hz User Manual Display Interface FAN COOL SLEEP SET TEMP SET TIME AUTO LOW MED HIGH °C °F ON OFF DRY na3360a Display Screen Information Item Function Description 1 Sleep mode indicator Sleep mode is an undercooling mode that is used during times of non- peak heat. Sleep mode is activated by setting the timer. The set temperature will automatically increase at intervals until the timer turns off the Sleep mode. 2 Cool mode indicator Cool mode cools the room. Temperature and fan speed are set by the user. 3 Fan mode indicator Fan mode moves air only. The fan speed is set by the user. 4 Dry mode indicator Dry mode dehumidifies the room. The fan speed is Low only. 5 Set Time Displays the timer interval (0.5 to 24 hours) and if the timer is on or off. 6 Fan Speed indicator Bars labeled Low, Medium and High indicate fan speed. 7 Auto mode indicator In auto mode the microprocessor chooses fan, cool or dry mode depending on the set temperature setting. 8 Set Temp Displays the set temperature. InRoom SC 60 Hz User Manual Function Button and Indicator Light Operation Cooling Mode. In Cool mode the unit attempts to bring the room air temperature down to the set temperature. The fan speed and temperature are adjusted in Cool mode. Note: The room temperature must be higher than the set temperature in order for the cooling mode to start. Dry Mode (Dehumidify). Press the ON/OFF button to start the cooling unit. Press the Mode button to choose Dry. In Dry mode, the fan speed is fixed to Low. • In Dry mode, air is not exhausted to the outside. Fan Mode. When in Fan mode, air is circulated with no cooling. Low, Medium, and High fan speed can be selected. Indicator bars on the display show the fan speed.. Auto Mode. The cooling unit will automatically choose the Cool, Dry, or Fan mode to ensure the indoor constant temperature efficiency based on the set temperature you have selected. Sleep Mode. Sleep mode is an energy saving mode. The Sleep mode temperature must be preset. When Sleep mode starts (in Cool mode), the temperature increases by two degrees after one hour and four degrees after two hours. After two hours the cooling unit will run at the preset temperature. In Fan or Auto mode, the temperature is not changed during Sleep mode because cooling is not occurring. Timer Control. Auto OFF: With the cooling unit running in Cool mode, press the Timer button to start the timer function. Press the up or down arrow buttons to select the number of hours (from 0.5 to 24) the unit will run before it automatically shuts off. Auto ON: With the cooling unit powered on but in standby mode (no mode selected), press the Timer button to start the timer function. Press the up or down arrow buttons to select the number of hours before the cooling unit automatically starts running in Cool mode. Temperature Control. The default display is the set temperature. • The set temperature is only adjustable in Cool mode. • Press the up arrow button to inc...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - INROOM SC ACPSC2000 (1.09 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien