Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung APC, modell INROOM ACPCW40-150

Hersteller: APC
Dateigröße: 814.06 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


(ft.) 1.17 (12.63) 1.46 (15.72) 1.86 (20.02) 2.22 (23.90) Rows Deep 4 4 4 5 Face Velocity m/min (ft/min) 94 (309) 114 (375) 125 (411) 153 (502) Valve size 32 (1.25) 40 (1.5) 32 (1.25) 40 (1.5) Connection Sizes In/Out - mm (in) 35 (1 3/8) 42 (1 5/8) 42 (1 5/8) 55 (2 1/8) * Nominal Rating Point InRoom Precision AC Tech Data Manual Information common to both modes PGE211 Cabinet Size 2 PGE311 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 Connection Sizes Humidifier Supply Line - mm (in) 6 (1/4) 6 (1/4) 6 (1/4) 6 (1/4) Condensate Drain Line - mm OD (in ID) 21 (3/4) 21 (3/4) 21 (3/4) 21 (3/4) Fan Information Number of Fans 1 2 2 3 Air Flow - M./hr (CFM) 6643 (3,910) 10007 (5,890) 14000 (8,240) 400 (14,130) External Static Pressure - Pa (in WC) 50 (0.2) 50 (0.2) 50 (0.2) 50 (0.2) Sound Power Level - dBA 71.2 71.9 76.7 79.5 Total Fan Power Consumption - kW (hp) 0.7 (0.9) 1.4 (1.9) 32.5 (3.4) 4.7 (6.3) Humidification – Solid State Electrode, Canister Flush Cycle Automatic Automatic Automatic Automatic kg/hr (lb/hr) 8.0 (17.6) 8.0 (17.6) 15.0 (33.1) 15.0 (33.1) Electric Reheat – Equally Loaded Three (3) phase Capacity - kW (BTU/hr) - Includes Motor Heat 460 V 12.0 (40982.4) 18 (61473.6) 18 (61473.6) 27 (92210.4) 230 V 9.0 (30736.8) 18 (61473.6) 18 (61473.6) 27 (92210.4) Number of Stages 2 3 3 3 Downflow Filters - mm Quantities 1050 x 453 x 47 G4 2 1 1 1 1050 x 398 x 47 G4 1 3 4 5 Upflow Filters - mm Quantities 700 x 340 x 47 G4 1 N/A 1 1 700 x 332 x 47 G4 1 N/A N/A 1 700 x 502 x 47 G4 1 1 1 1 700 x 508 x 47 G4 N/A 1 1 2 700 x 516 x 47 G4 N/A 1 N/A N/A Physical Data Weight - kg (lb) 470 (1036) 584 (1287) 716 (1578) 893 (1969) Height - mm (in) 1980 (77.95) 1980 (77.95) 1980 (77.95) 1980 (77.95) Width - mm (in) 1000 (39.37) 1400 (55.11) 1750 (68.90) 2150 (84.65) Depth - mm (in) 890 (35) 890 (35) 890 (35) 890 (35) InRoom Precision AC Tech Data Manual 60Hz InRoom Electrical Specifications Air Cooled (DX) and Fluid Cooled (Glycol) Electrical Data With Reheat and Humidification Without Reheat and Humidification Compressor Data Model Size Airflow Pattern Cooling System Voltage (3ph/60Hz) MCA MOP Power (kW) MCA MOP Power (kW) LRA RLA 211 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 67.3 70 20.6 33.3 50 10.6 137 19.3 460-480 34.5 35 21.0 15.6 20 9.9 62 9.1 575-600 30.2 35 29.3 15.2 20 11.3 62 9.1 PGEXXX 208-230 84.3 90 25.7 33.3 50 10.6 137 19.3 460-480 43.8 50 26.6 15.6 20 9.9 62 9.1 575-600 37.7 40 39.3 15.2 20 11.3 62 9.1 311 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 100.3 125 30.4 49.3 80 15.3 195 32.1 460-480 53.0 60 32.0 24.7 40 15.3 95 16.4 575-600 42.2 45 32.3 19.9 30 14.3 95 16.4 PGEXXX 208-230 109.5 125 30.4 49.3 80 15.3 195 32.1 460-480 57.2 60 32.0 24.7 40 15.3 95 16.4 575-600 45.8 50 35.7 23.3 35 17.7 95 16.4 452 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 116.0 125 37.3 65.0 80 22.2 156 20.7 460-480 59.2 60 37.8 30.9 40 21.0 75 10.0 575-600 42.5 45 36 29.3 35 24.7 75 10.0 PGEXXX 208-230 141.6 150 44.9 65.0 80 22.2 156 20.7 460-480 73.4 80 46.2 30.9 40 21.0 75 10.0 575-600 53.7 60 43.5 29.3 35 24.7 75 10.0 612 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 167.3 175 53.3 90.6 100 30.6 195 32.1 460-480 87.8 90 55.7 45.3 60 30.5 95 16.4 575-600 57.1 60 44.7 35.3 45 27.1 95 16.4 PGEXXX 208-230 176.5 200 56.7 99.8 125 34.0 195 32.1 460-480 92.0 100 58.8 49.5 60 33.6 95 16.4 575-600 60.5 70 48.1 38.7 50 30.5 95 16.4 862 Up/ Down PAXXX PGXXX PACWXXX PGCWXXX 208-230 210.2 225 67.8 133.6 175 45.1 245 47.1 460-480 104.8 125 67.3 62.3 80 42.1 125 22.1 575-600 65.4 70 51.9 47.5 60 38.1 125 22.1 Note: Above data is based on maximum operating conditions Installation must comply with all local and/or national electrical codes. MCA - Minimum Circuit Ampacity MOP - Maximum Overcurrent Protection LRA - Compressor Locked Rotor Amps RLA - Compressor Rated Load Amps InRoom Precision AC Tech Data Manual Chilled Water (CW) Electrical Data With Reheat and Humidification Without Reheat and Humidification Model Size Airflow Pattern Cooling System Voltage (3ph/60Hz) MCA MOP Power (kW) MCA MOP Power (kW) 400 Down PCWXXX 208-230 59.0 60 18.8 9.9 15 3.1 460-480 32.7 35 20.8 4.4 15 2.8 575-600 28.7 30 22.9 6.2 15 4.9 400 Up PCWXXX 208-230 60.6 70 19.3 11.5 20 3.7 460-480 33.5 35 21.4 5.3 15 3.3 575-600 28.7 30 22.9 6.2 15 4.9 660 Up/Down PCWXXX 208-230 91.6 100 29.2 19.8 25 6.3 460-480 46.5 50 29.6 8.9 15 5.7 575-600 39.7 40 31.7 9.7 15 7.7 900 Up/Down PCWXXX 208-230 109.4 125 34.9 23.0 25 7.3 460-480 56.4 60 35.9 10.5 15 6.7 575-600 47 50 37.6 10.4 15 8.3 1100 Up/Down PCWXXX 208-230 135.0 150 43.0 23.0 25 7.3 460-480 70.6 80 45.0 10.5 15 6.7 575-600 47 50 37.6 10.4 15 8.3 1500 Up/Down PCWXXX 208-230 146.5 150 46.7 34.5 35 11.0 460-480 75.9 80 48.4 15.8 20 10.0 575-600 62.5 70 50 14.7 20 11.7 Note: Above data is based on maximum operating conditions Installation must comply with all local and/or national electrical codes. MCA - Minimum Circuit Ampacity MOP - Maximum Overcurrent Protection LRA - Compressor Locked Rotor Amps RLA ...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - INROOM ACPDX21-86 (814.06 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien