Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung APC, modell AP7004

Hersteller: APC
Dateigröße: 613.23 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The Tank Full indicator will flash on the control panel and the unit will beep several times when the tank is full or has been removed from the unit. For safety reasons, the compressor stops at this time. The fan will continue to operate at the same speed. However, if the tank is not emptied or reinserted within three minutes, the fan will stop. Caution: Do not remove the tank when the unit is in use. Always turn off the unit before removing the tank. Periodically inspect and clean the drain valve to prevent clogging. Continued on next page Drainage continued Emptying the tank To manually drain the tank: 1. Turn off the unit. 2. Using the handle, slowly remove the tank from the side of the unit. 3. Pour out any condensation accumulated in the tank. 4. Wipe up any condensation that may have drained off the evaporator coil. 5. Replace the tank in the unit. 6. Turn the power on and make sure tank is properly seated (the unit will beep and Tank Full indicator will flash if tank is not properly positioned). 7. Allow the fan to run for an additional three minutes after emptying the tank to dry out the moisture in the evaporator coil. Continued on next page Drainage continued The drainage 1. Slide out the drain valve from the left side of the unit. tube 2. Attach the drainage tube to the drain valve. 3. Route the tubing downward so that condensate flows properly into a floor drain or condensate line below the unit. Note: Condensation will drip through the drain valve if it is open. Make sure there is a hose attached to the it and a floor drain or condensate line below the unit whenever the drain valve is open. Maintaining the Unit Clean the air filter Clean the cabinet APC recommends cleaning your air filter at least after every two weeks of use. Keeping your air filter clean will maximize the performance and life of this product. 1. Turn off the unit and unplug it from its electrical outlet. 2. Open the air filter on the left side of the unit. 3. Remove the air filter from the cover. 4. Wash air filter with a neutral detergent and warm water and let it air dry. 5. Reinsert the filter into the cover. Turn off the unit and unplug it from its electrical outlet. Clean the surface of the cabinet with warm water and a neutral, nonabrasive detergent. Ensure all detergent is wiped from the surface and rinse with clear water to remove residue. Caution: Do not clean the surface with thinners, alcohol, polishing powder, alkaline detergent, acid, or an abrasive brush. Using these items will damage the cabinet. Continued on next page Maintaining the Unit continued Clean the condensate tank regularly 1. Turn off the unit and unplug it from its electrical outlet 2. Using the handle, slowly remove the condensate tank from the side of the unit. 3. Pour out any condensation accumulated in the tank. 4. Clean the inside of the tank with a solution of warm water and mild detergent to avoid the growth of mold and mildew. 5. Replace the tank in the unit. 6. Turn the power on and make sure tank is properly seated (unit will beep and Tank Full indicator will flash if tank is not properly positioned). 7. Allow the fan to run for an additional three minutes after emptying the tank to dry out the moisture in the evaporator coil. Continued on next page Maintaining the Unit continued Storing the Unit The following precautions must be taken when storing the unit for extended periods of time: 1. Turn off unit. 2. Clean the air filter and allow to air dry before replacing in unit. 3. Empty the condensate tank. 4. Remove the stopper from the water drain pipe and drain until empty. Reinsert the water drain pipe into the unit. Water Drain Pipe Stopper 5. Replace the tank. 6. Turn the unit on and allow the fan to run three minutes after emptying the tank to dry out the moisture in the evaporator coil. 7. Turn power off. Power cable must be disconnected from power outlet and neatly rolled. 8. Store the unit in a dry place. Troubleshooting Try this first Problem Cause Suggestion Unit is not plugged in. Securely plug receptacle into the wall. Unit does not work Main power is off. Check fuse or circuit breaker Condensate tank is full. Indicator light is on. Empty tank. Air exhaust or intake blocked. Clear all objects away from air grills, move away from wall. Poor cooling performance. Air filter is dirty. Clean air filter. Temperature is set too high. Lower set temperature. Fan speed is too low. Increase fan speed. Noise or vibration. Surface is not level. Place unit on a level surface, away from obstructions. Unit starts and stops. Air exhaust is not attached properly or is curved too much. Check installation of air exhaust hose. Troubleshooting continued Try this first, continued Problem Cause Suggestion Drain tube is clogged. Remove blockage. Condensate tank is improperly seated. Reposition tank. Surface not level. Place unit on a level surface away from obstructions. Water is leaking from unit. Damaged condensate tank. Replace tank. Stopper on water...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - AP7003 (613.23 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien