Login:
Stimmen - 5, Durchschnittliche Bewertung: 4 ( )

Anleitung Panasonic, modell CS-A9CKP

Hersteller: Panasonic
Dateigröße: 402.75 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


2 Wash back of the air filter with water. 3 If badly soiled, wash it with soap or a mild household detergent. 4 Let it dry and reinstall it. Be sure the “FRONT” mark is facing you. *Damaged air filter. Consult the nearest authorized dealer. Part No.: CWD001047. • Do not use benzene, thinner, scouring powder or clothes soaked in caustic chemical to clean the unit. Cleaning the Front Panel (Must be removed before washing) 1 Raise the front panel higher than the horizontal and pull to remove it. 2 Gently wash with water and a sponge. • Do not press the front panel too hard when washing. • When use kitchen cleaning fluid (neutral detergent), rinse thoroughly. • Do not dry the front panel under direct sunlight. 3 To fix the front panel, raise the front panel horizontally, match the protruding portion on the indoor unit to the fulcrum and push into place. Air Purifying Filters Triple Deodorizing Filter • Absorb odours produced by wall paper, construction material and living environment. • Reusable. • Vacuum, place under direct sunlight for 6 hours and fit it back in place. (Recommended: every 6 months) Catechin Air Purifying Filter • The filter is coated with catechin to prevent growth of bacteria and viruses. • Reusable. • Vacuum and fit it back in place (Recommended: every 6 months) • Recommended to change these filters every 3 years. Do not reuse damaged filters. Consult the nearest authorized dealer to purchase a new filter. Catechin Air Purifying Filter No.: CZ-SF70P Triple Deodorizing Filter No.: CZ-SFD72P • If you operate the air conditioner with dirty filters:– Air is not purified – Cooling or heating capacity decreases – Foul odour is emitted Heat Pump Model COOL –> 8°C or above HEAT –> 14°C or above Cooling Model COOL –> 8°C or above Heat Pump Model COOL operation with 30°C set temperature Cooling Model FAN operation Fulcrum Protruding portion on indoor unit 2 Remove the air filters 1 Raise the front panel Catechin Air Purifying Filter Triple Deodorizing Filter HELPFUL INFORMATION Auto Operation Button Automatic Operation • If the remote control fails to function or has been misplaced, press the Auto Operation button to start the Automatic operation. • The Automatic operation will be activated immediately once the Auto operation button is pressed. However, temperature cannot be adjusted in this operation. • The power indicator on the indoor unit will blink until the operation mode is selected automatically. • To cancel this operation, press once more. Remote Control Signal Receiving Sound • To switch off the beep (Signal Receiving Sound), press the Auto Operation button for 10 seconds continuously or longer. “Beep”, “beep” sound will be heard at the tenth seconds. Note: “Beep” sound will be heard at the fifth seconds; However please press continuously until you heard “beep”, “beep” sound. • Repeat the above steps if you want to switch on the Signal Receiving Sound. (This is for Servicing purposes only) Note: If you press this button continuously for 5 to 10 seconds, Test Run operation will be performed. A “beep” sound will be heard at the fifth seconds indicating the Test Run starts to operate. • Raise the front panel and press ¦ Auto Restart Control • If power is resumed after a power failure, the operation will restart automatically after 3 - 4 minutes. • Operation will be restarted automatically under the previous operation mode and airflow direction when power is resumed as the operation is not stopped by the remote control. ¦ Timer Setting • When power failure occurs, the timer setting will be cancelled. Once power is resumed, reset the timer. ¦ Thunder and Lightning • This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may switch off the main power supply and unplug from power socket. ENERGY SAVING AND OPERATION HINTS Setting the Temperature • Approximately 10% of electricity can be saved. • Set the temperature higher or lower than the desired temperature. Cooling Model Cooling Operation : 1°C higher Heat Pump Model Cooling Operation : 1°C higher Heating Operation : 2°C lower Air Filters and Air Purifying Filters • Clean the air filters every 2 weeks and the Air Purifying Filters every 6 months. • Dirty filters may reduce cooling or heating efficiency. Keep All Doors and Windows Closed • Otherwise, cooling or heating performance will be reduced and electricity cost is wasted. Outdoor Unit • Do not block the air outlet vents. Otherwise, it will lower the cooling or heating performance. Timer Mode • To prevent wastage of electricity, use Timer when going out. Avoid Direct Sunlight • Keep curtains or drapes closed to avoid direct sunlight during cooling or heating operation. 42 CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5 TROUBLESHOOTING Normal Operation Is it okay? • Air conditioner has been restarted, but does not operate for 3 minutes. • ...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - CS-A7CKP (402.75 kb)
Splitgeräte - CS-A12CKP (402.75 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien