Anleitung Panasonic, modell CS-A24CTP

Hersteller: Panasonic
Dateigröße: 1.49 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Sleep Operation button is pressed. 0~1 hour Approx. 2°C decrease. Approx. 0.5°C increase. Approx. 0.5°C increase. Temperature S e t t i n g T e m p e r a t u r e Time < 1 hour > after approx. 8 hours of sleep shift operation, it will stop automatically. Time Approx. 0.5°C increase. Temperature Sleep Operation button is pressed. Sleep shift operation starts. 0~1 hour < 1 hour > after approx. 8 hours of sleep shift operation, it will stop automatically. Approx. 0.5°C increase. • Cooling or Soft Dry Operation for sleep shift operation will start to avoid overcooling. S e t t i n g T e m p e r a t u r e CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Setting the Fan Speed • Press 4 to select:FAN – Low Fan Speed FAN – Medium Fan Speed FAN – High Fan Speed AUTO FAN – Automatic Fan Speed The speed of the indoor fan is adjusted automatically according to the operation. The indoor fan stops occasionally during cooling operation. Vertical Airflow Direction Manual Operation • Press and hold the Manual Airflow Direction Selection Button 5 , then release the button at the desired airflow direction. • Cooling / Soft Dry/ Heating (for Heat-Pump Model only) The airflow direction can be adjusted as desired by using the remote control. This is effective when you want to cool yourself directly, such as when coming out of the bath. The louver can be adjusted within a range between the horizontal and 25 degrees downward at Cooling and Soft Dry Operation, and between the horizontal and 45 degrees downward at Heating Operation. (for Heat-Pump Model only) Setting the Horizontal Airflow Direction Use this air conditioner under the following conditions: Cooling Model • Adjust it manually Notes • If the unit is not going to be used for an extended period of time, turn off the main power supply. If it is left at the ON position, approximately 2.0 W of electricity will be used even if the indoor unit has been turned off with the remote control. • If operation is stopped, then restart immediately, the unit will resume operation only after 3 minutes. DBT: Dry Bulb Temp WBT: Wet Bulb Temp Maximum Temperature-Cooling (Maximum Temperature-Heating) Minimum Temperature-Cooling (Minimum Temperature-Heating) DBT 32 (30) 16 (16) WBT 23 (-) 11 (-) DBT 43 (24) 16 (-5) WBT 26 (18) 11 (-6) Indoor Outdoor (Unit in °C) Heat Pump Model DBT: Dry Bulb Temp WBT: Wet Bulb Temp Maximum Temperature Minimum Temperature DBT 32 16 WBT 23 11 DBT 43 16 WBT 26 11 Indoor Outdoor (Unit in °C) Downward Horizontal Automatic Operation • Press the Auto Airflow Direction Button 6. • Cooling / Soft Dry The louver will automatically swing up and down to create the feeling of a refreshing breeze. • Heating (for Heat-Pump Model only) When the discharge air temperature is low such as at starts of heating operation, the air blows at horizontal level. As the temperature rises, the hot air blows in a downwards direction. H OFF H ON H ON OFF H 37 CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5 Pre-season Inspection Clean the air filters, re-insert and operate the air conditioners. Is the discharged air cold / warm? Operation is normal if 15 minutes after the start of operation, the difference between the air intake and outlet vents temperature is: Are the air intake or outlet vents of the indoor or outdoor units obstructed? Are the remote control batteries weak? If the remote control display appears weak, replace the batteries. When the Air Conditioner is Not Used for an Extended Period of Time 1 To dry the internal parts of the indoor unit, operate the unit for 2 - 3 hours using:2 Turn off the power supply and unplug. 3 Remove the remote control batteries. Recommended Inspection • After used over several seasons, the unit will become dirty and thus decreases the unit’s performance. Depending on the operation conditions, a dirty unit may produce odour and dust may pollute dehumidification system. Therefore, a seasonal inspection is recommended in addition to regular cleaning. (Consult an authorized dealer). Cooling Model FAN operation Heat Pump Model COOL operation with 30°C set temperature Cooling Model COOL –> 8°C or above Heat Pump Model COOL –> 8°C or above HEAT –> 14°C or above HELPFUL INFORMATION Auto Operation Automatic Operation • If the remote control fails to function or has been misplaced, press the Auto Operation button to start the Automatic operation. • The Automatic operation will be activated immediately once the Auto operation button is pressed. However, temperature cannot be adjusted in this operation. • The power indicator on the indoor unit will blink until the operation mode is selected automatically. • To cancel this operation, press once more. Timer Setting • When power failure occurs, the timer setting will be cancelled. Once power is resumed, reset the timer. Thunder and Lightning • This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from ...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - CS-A18CTP (1.49 mb)
Splitgeräte - CS-A12CTP (1.49 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien