Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.5 ( )

Anleitung EdgeStar, modell AP10000HW

Hersteller: EdgeStar
Dateigröße: 932.24 kb
Dateiname: b0658c1f-f568-4414-9b4d-951f5f70f940.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Working range for heating function is 41 to 81oF. For temperature outside this range. the unit may not work properly. 11 12 Operation – Using the Remote Control Operation – Adjusting the Louvers Regulating air flow direction FIG.14 Move the roller on the air vent to the left or right to control the air flow direction. NOTICE ! 1. To prolong the compressor's life, please wait at least 3 minutes before turning the unit back on after shutting it off. 2. The cooling system will shut off if the ambient temperature is lower than the set one. The fan, however, keeps working on the set level. If the ambient temperature rises above the selected level, the cooling system will return to operation. All the control panel functions can also be set with the remote control. 1. LED Indicator – Lights up when you press any of the buttons. 2. Power Button – Used to power the unit on or off 3. Mode Button – Used to change between auto, cooling, heating, or fan modes. 4. Timer Button – Used to set the timer function. 5. Up Button – Used to increase the temperature. 6. Down Button – Used to decrease the temperature. 7. Fan Speed Button – Used to set the fan speed. 1 2 3 4 5 6 7 Note: The remote uses two AAA batteries. higher than the set one(still, the ventilation keeps working on the set level). As the ambient temperature drops below the selected level, the heating will order to melt the frost. As this occurs, just wait for the heating returns to work. function during low temperature, sometimes the heating will stop for a while in return to work. 3. On the contrary, the heating will swith off if the ambient temperature is 4. This machine is equipped with ANTI-FROST function. While using the heating 13 Maintenance – Water Drainage This portable air conditioner is designed to exhaust most or all water dehumidified from the air. In high humidity situations, the internal water reservoir may fill. If the reservoir is full, both the compressor and motor will stop and the unit will buzz a warning (you can press any button to stop the buzzing). The “Water” indicator will flash to show you that the reservoir is full. The unit will not operate until you drain the water. Please empty the water in one of the following ways: 1. Turn off the air conditioner (avoid moving it when full). 2. Position a container (a water tray, for example) underneath the drain hole. 3. Remove the drain cap & rubber plug from the drain hole and allow the water to drain out. 4. When the container is almost full, replace the rubber plug in the drain hole and empty the water tray. 5. Repeat until the unit is emptied. 6. Replace the rubber plug and tighten the drain cap firmly. 7. Switch on the unit – the Water Full indicator will stop flashing. FIG.15 If you wish to operate the unit without the need to empty the water tank, please: • Remove the drain cap and rubber plug and retain for future use. • Connect the drain tube supplied to the water outlet as shown and locate the other end into a drain. (see the next page for more information) FIG.16 Drain hole Rubber plug Drain cap Rubber plug Drain cap 14 Maintenance – Extending the Drain Tube The drain tube may be extended by adding an extension tube and using a suitable connector. FIG.17 Please note 1. The drain must be at or below the outlet level. 2. Flashing Comp / Water indicator will not function in this mode of drainage. 3. This unit will not shut off when an external drain pan/tray is filled. 4. If you want to extend the water tube, you can connect it with another tube (Diameter: 0.71”) 5. When the room humidity is over 85%, we recommend continuous drainage. FIG.18 Drain tube Original drain tube Extended drain tube (Outer Diameter: 0.71”) 15 Maintenance – Cleaning the Unit Always unplug the air conditioner from the power outlet before cleaning. Clean the air conditioner regularly to maximize performance and efficiency. Cleaning the unit Use a soft damp cloth to wipe the body clean. Use a soft bristle brush to clean between the control panel’s buttons. Never use abrasive chemicals, gasoline, detergents, chemically treated cloths, or other cleaning solvents that may damage the cabinet exterior. Cleaning the pre-filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt, then rinse thoroughly under warm running water that is not hotter than 104o F. Dry thoroughly before replacing. Note: The activated carbon filter is not washable- replace it as needed. Contact EdgeStar retailers for replacement filters. Warning: Never operate the unit without the filters. Follow the instructions below to prepare your product for storage. 1. Drain all the water from the unit before storing. Operate the unit in fan mode for a few hours to thoroughly dry the inside. 2. Clean or change the filter. 3. Unplug and store the power cord as shown. 4. Replace the unit in the original carton, or cover it before storing away. FIG.20 Preparation for Storage Cord Optimizing Performance For Maximum Performance and Efficie...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien