Control panel 2. Carrying handle 3. Water tank 4. Casters 5. Air louvers Accessories 13. Exhaust hose 14. Exhaust hose adapter - goes over hose and into the window kit (or into a hole in a wall/window) 15. Adapter cover FIG.5 FIG.6 6. Air filter 7. Exhaust air outlet 8. Air filter 9. Air inlet 10. Cord storage 11. Air inlet 12. Water plug / drainage point FIG.7 16. Window spacer – goes into an 19. Drain hose for open window space continuous drainage 17. Window spacer – goes into an 20. Activated carbon filter open window space 21. Remote control 18. Window kit – goes into an open window space and connects to one end of the exhaust hose 3 INSTALLATION INSTRUCTIONS Installing the Exhaust Hose and Window Kit This portable air conditioner can be vented with either the window kit or with the exhaust hose adapter only: 1. Using the window kit: Window kit FIG. 8 • Open the window and insert the window kit into the open gap. • Close the window until the window kit is held securely. You may need to expand the size of the window kit using the included window spacers. This technique can also be used for sash windows. • Insert one end of the exhaust hose into the exhaust air outlet located on the back of the air conditioner. Attach the exhaust hose adapter to the other end of the exhaust hose and connect the adapter to the window kit. 2. Using the adapter: FIG.9 FIG.10 Wall or window Exhaust hose adapter • Cut a hole with a 6” diameter (152 mm) into a wall or window. • Insert one end of the exhaust hose into the exhaust air outlet located on the back of the air conditioner. Insert the other end of the exhaust hose through the wall or window opening and attach the exhaust hose adapter from the outside as shown. • Cover the hole with the included adapter cover when the air conditioner is not in use. 4 Positioning the Exhaust Hose • Only use the provided exhaust hose with this AC. Insert the exhaust hose into the back of the unit and secure it in place. • Avoid kinks and bends in the exhaust hose. These can cause expelled moist air to accumulate, resulting in overheating and unexpected shut-offs (fig. 11 and 12). • The exhaust hose may be extended from 12 inches (300 mm) to 59 inches (1500 mm), but for maximum cooling efficiency, use the shortest hose length possible. WARNING! The included exhaust hose is specifically designed to fit the specifications of this unit. Do not extend it with your own hose, as this can cause the air conditioner to malfunction. FIG.11 FIG.12 FIG.13 FIG.14 5 OPERATING INSTRUCTIONS Control Panel 1. ON/OFF button 2. Mode button 3. Temperature increase button 4. Temperature decrease button 5. Fan speed (ventilation) button 6. Timer button 7. Sleep mode button 8. Ionizer button (optional) Turning the Unit On and Off FIG.17 a. Display b. Heater indicator (AC-14100H only) c. Automatic mode indicator d. Cooling indicator e. Fan indicator f. High speed indicator g. Medium speed indicator h. Low speed indicator i. Receiver for remote control j. Timer indicator k. Sleep mode indicator l. Ionizer indicator m. Full tank indicator • Press the ON/OFF button. The unit will work in cooling mode on low fan speed. The preset temperature is 75°F (24°C). • At this time, the indicator lights showing any functions in progress will turn on. Please note that the display window will only show ambient room temperatures from 32°F to 122°F (0oC to 50oC). • To turn the unit off, press the ON/OFF button again. 7 Setting the Mode/Function 1. Press the MODE button to select the desired mode (cooling, fan, heating). Please note that the heating function is only available in the AC-14100H. 2. The selected mode’s indicator light will turn on. Setting the Temperature 1. Press the increase temperature or decrease temperature button to change the set temperature. 2. The display window will then indicate the set temperature. If no temperature is set, the display will show the room’s ambient temperature. 3. The preset temperature is 75°F for cooling and 68°F for heating. Setting the Fan/Ventilation Speed Press the fan speed button to select the desired fan speed. The appropriate indicator light will turn on accordingly. Setting the Timer 1. Press the TIMER button to set the desired number of operating hours (from 1 to 24 hours). When the set time has been reached, the machine will automatically turn off. The display window will show the number of hours being set as you press the TIMER button. If the TIMER is not set, the unit will work continuously. 2. By pressing the TIMER button without selecting any other modes or settings, you can set the number of hours to be delayed before the unit turns on. For example, if you press the TIMER to “2”, the unit will automatically turn on after 2 hours. Sleep Mode 1. When the unit is in cooling mode, press the SLEEP button and the set temperature will automatically increase by 1oF on the 1st hour, another 1 ° F on the second hour, and then stay at that temperature. 2. When the unit is in heating m...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - AC-14100H (3.8 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien