Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung NewAir, modell ACP-1400E

Hersteller: NewAir
Dateigröße: 1.54 mb
Dateiname: 58d37bc3-3aa5-46e2-845c-4b8945e93438.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use your new air conditioner you should carefully read these instructions to maximize this product’s performance. SAFETY INSTRUCIONS IMPORTANT! • The unit is designed for indoor operation. • The installation must be in accordance with regulations of the country where the unit is used. If you are in any doubt about the electrical installation, have it checked and if necessary modified by a qualified electrician. • The air conditioner is safe. However, as with other electrical appliances, use it with care. • Keep out of the reach of children. • Do not clean the air conditioner by spraying it or immersing it in water. • Do not insert any object into openings of the air conditioner. • Disconnect it from all electricity before cleaning the unit or any of its components. • Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a licensed electrician. • Don’t lift or move by pushing the air conditioner at the rear, but always from the front side. WARNING • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer, its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. 4 Do not use your air conditioner under the following conditions : • If the power cable wires are frayed or cut • Where small children may be left unattended • On a slope or uneven surface • Close to a naked flame • This product is not made for DIY repair • If there is a risk of liquid falling on the unit • Inside unit exposed to the weather outdoors • Near water • If an extension lead may become overloaded • Where the power cable may be damaged • Where it may be damaged by chemicals • Where there is a risk of interference by foreign objects 5 PARTS ( OLD ) ( NEW ) (1) Front panel (2) Air outlet (3) Control panel (4) Rear panel (5) Right air inlet (6) Castor (7) Left air inlet (8) Hose connector (9) Exhaust hose (10) Drainage point with rubber water stopper 6 ACCESSORY Exhaust Hose Hose Connector Telescopic Slide Bar Connecto(r NEW) Telescopic Slide Bar Connecto(r OLD) Telescopic Slide Bar Carbon Filter Water Container Remote Control 7 CONTROL PANEL LED Indicator Light 1 – Ionizer & UV indicator light in green 2 – Swing indicator light in green 3 – Timer indicator light in green 4 – Sleep mode indicator light in green 5 – Fan speeds a. Fast – indicator light in red b. Normal - indicator light in green c. Slow - indicator light in yellow 6 – Mode a. Cooling – indicator light in green b. Dehumidification – indicator light in yellow c. heat – indicator light in red d. Fan only – no light 7 – When the unit is working, the indicator light will be in green 8 – Water full indicator light in red 8 INSTALLATION WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another. In doing so keep this in mind: - Ensure that the unit is positioned upright, on a level surface and 50cm away from any obstacles. - Do not operate the unit inside the bathroom, shower, or in any other very humid environment. - Slide the hose connector A in the hot air outlet. - Connect the hose to hose connector A by turning it clockwise (at least 5 turns). - Similarly, connect the hose to hose connector B as far as possible. (OLD) (NEW) - Slide the hose connector B in the telescopic slide bar connector. - Place the telescopic slide bar in the open window or door and adjust the length to fill as much open space as possible. (OLD) (NEW) - Close the window or door as much as possible to prevent outside air entering the room. - Ensure that the hose connector B has a free flow outside. - 9 IMPORTANT! The flexible exhaust hose can be extended from 500 to 1500mm for mounting. This length has been designed especially according to the specifications of the air conditioner. Do not use an extension or exchange for a different hose as that may cause the unit to malfunction. The exhaust air must flow freely; any blockage can lead to overheating of the air conditioner. Take care to prevent any sharp bow or bend in the exhaust. O PERATION O N/OFF Press to switch the unit on or to switch off, a buzzer will beep, and the 2 digits display will show 72. as default, and the unit will run in cooling function with turbo speed (the indicator light in red, the indicator light in green). Setting the temperature If you want to change the set temperature press the or button. The 2 digit display will indicate the set temperature. Note: Reaching the set temperature depends on the room a...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien