Anleitung Denso, modell OFFICE PRO 18
Hersteller: Denso Dateigröße: 1.52 mb Dateiname: officepro18-manual.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
. AM/PM LED Illuminates to indicate AM or PM time of day. . Program RUN Activates/deactivates a program. Button . Program SET Allows the user to program the unit or Button check the current program. START TIME LED Illuminates to indicate the current step END TIME LED that is being programmed into the unit. SET CLOCK LED CLOCK/TIMER Allows the user to set the clock and program Buttons the start and end time of operation. 9 OPERATION (cont.) Operating in COOL Mode . The unit can be operated in COOL mode by pressing the COOL ON/OFF button (LED illuminates). NOTE: In COOL mode the unit can only be turned off by pressing the COOL ON/OFF button again, not by pressing the fan buttons. . Change the fan speed by pressing the HIGH or LOW fan buttons. . Change the temperature set point by pressing the SET TEMP buttons (Ў/^). NOTE: When turning the unit on, the set point and fan speed are determined by the last operating mode (program mode not included). Operating in Fan Only Mode . The unit can also be operated in Fan Only mode by pressing either the HIGH or LOW fan buttons (LED illuminates). . The unit can then be turned off by pressing the fan speed button that is illuminated. Changing from Fan Only Mode to COOL Mode The COOL mode can be activated while the unit is operating in Fan Only mode. To do this, simply press the COOL ON/OFF button (LED illuminates). NOTE: The Fan Only mode will not operate after the COOL mode has been activated. After the COOL mode has been activated, the unit cannot be turned off by pressing the fan buttons. The COOL ON/OFF button must be pressed. 10 OPERATION (cont.) How to Set a Program . Setting a START TIME Press the Program SET button. The Program SET button and START TIME LEDs will illuminate. Press the HRS and MIN buttons to set the START TIME. . Setting an END TIME Press the Program SET button until the END TIME LED illuminates. Press the HRS and MIN buttons to set the END TIME. . Setting the CLOCK TIME Press the Program SET button until the SET CLOCK LED illuminates. Press the HRS and MIN buttons to set the current clock time into the unit. NOTE: The AM/PM LED will change with the HRS button. . Programming the Temperature SET POINT Press the Program SET button until the current SET POINT temperature display begins to flash on and off. Select a new desired SET POINT temperature (65.F – 90.F) by pressing the SET TEMP buttons (Ў/^). . Programming the Fan Speed Press the Program SET button until one of the Fan Speed button LEDs (HIGH/LOW) begin to flash. This is the current programmed Fan Speed. To change the programmed Fan Speed, simply press the other Fan Speed button. . Exiting the Program SET Function After changing any of the above settings, continue pressing the Program SET button until the Program SET button LED turns off. The unit will then return to the previous mode. . Activating/Deactivating a Preset Program Press the Program RUN button to activate/deactivate a preset program. The Program RUN LED will illuminate when activated. 11 OPERATION (cont.) How to Set a Program (Cont.) NOTE: • The unit will return to the previous mode if a program is turned off while it is running. • The Program RUN LED flashes while a program is running. It is illuminated continuously when the program mode is activated. • While a program is running, the program can only be stopped by pressing the Program RUN button. All other buttons are inoperable when a program is running. • The unit returns to the previous mode at the end of a program. • The unit does not have to be running to set a program. • During programming, the unit returns to the previous mode if no activity occurs within approximately 35 seconds. 12 OPERATION (cont.) Operating Modes The Office Pro 18 operates in two modes, Fan Only and COOL. When in Fan Only mode, the unit circulates the surrounding air. When in COOL mode, the compressor is operational and cool air is circulated. • COOL Mode The unit will operate in Fan Only mode for approximately 120 seconds before the compressor engages. (Time delay setting is 120 ± 15 seconds.) • Temperature Control The room temperature thermistor allows the unit to switch automatically between COOL and Fan Only modes. This is dependent upon inlet air temperature versus SET POINT temperature. • Fan Mode Control DIP Switch The Fan Mode Control DIP Switch determines whether the FAN will continue to operate or stop when the compressor cycles off. (SET POINT temperature equals inlet air or room temperature.) The unit has been preset at the factory for continuous fan operation. • Temperature Scale Display DIP Switch The Temperature Scale Display DIP Switch changes the temperature(s) that are displayed to either °C or °F. The unit has been preset from the factory to display the temperature(s) in °F. NOTE: If you wish to change the fan mode operation (COOLOPERATE to COOLSTOP), and/or the Temperature Scale Display (°F to °C), contact your MovinCool reseller. 13 OPERATION (cont.) Emptying the Drain Tank During...