Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung HP, modell HP Integrity rx6600 Server

Hersteller: HP
Dateigröße: 186.6 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


Power Management Patches for HP-UX 11i v3 (B.11.31) patches
The following patches add support for power management on HP-UX 11i v3. These patches can
be found on the HP IT Resource Center (ITRC) web site at http://itrc.hp.com and will be
added to HWEnable11i bundle for March 2008:
• HP-UX 11i v3:
PHKL_36654
Power Mgmt enablement for pwr module
• HP-UX 11i v3:
PHKL_36477
11.31 acpi cumulative patch (in HWEnable11i for Sept 2007)
• HP-UX 11i v3:
PHKL_36478
11.31 acpica cumulative patch (in HWEnable11i for Sept 2007)
• HP-UX 11i v3:
PHKL_37031
Power Mgmt enablement for cec_hp module
• HP-UX 11i v3:
PHKL_37032
Power Mgmt enablement for cec_gen module
HP Insight Power Manager (IPM) is an integrated power monitoring and management
**application** that provides centralized control of server power consumption and thermal output
at the datacenter level. See the following web site for more information: www.hp.com/go/ipm.
Audio Patches for HP-UX 11i v2 (B.11.23) and 11i v3 (B.11.31)
System firmware level 03.01 changes the mapping of I/O port space for the audio driver. This
change affects applications that generate an audio output for an installed sound card. In most
cases, the audio application will hang, and no audio will be produced. To resolve this issue,
download the following patches from the HP IT Resource Center (ITRC) web site at http://
itrc.hp.com
:

• HP-UX 11i v2:
PHKL_36983
11.23 I/O Port Space Access fix for Audio driver (in HWEnable11i for Dec
2007)
• HP-UX 11i v3:
PHKL_36984
11.31 I/O Port Space Access fix for Audio driver (in HWEnable11i for March
2008)
Ignite-UX Recovery Procedure for SAS Devices: Attached Storage disks on
Core IO for rx2660, rx3600 and rx6600 on HP-UX 11i v2 and HP-UX
11i v3 in legacy mode
DESCRIPTION
When using Ignite-UX to reinstall or recover a system on HP-UX 11i v2 and for
legacy devices on HP-UX 11i v3, the hardware path for SAS devices may unexpectedly change
if certain changes were made to the SAS device configuration. Such changes to the SAS device
configuration may result in a loss of data when system recovery is attempted.
Ignite-UX uses the hardware path of a device as the unique identifier for a device. Certain changes
to the SAS device configuration breaks the ability of Ignite-UX to automatically access the correct
devices when the SAS configuration changes. Only certain changes break the association of
hardware path to SAS device.
The following SAS configuration changes may cause the hardware path associated with a SAS
device to change if the system is reinstalled or recovered:

Placing a SAS device into an empty lower numbered Bay

Creating/Updating (adding or deleting) a SAS RAID device post-installation

Swapping two or more SAS devices

Permanently removing a SAS device when there are still devices in higher numbered bays

Moving a SAS device from one SAS Host Bus Adaptor (HBA) to another
When HP Integrity rx2660, rx3600 and rx6600 servers are shipped from HP, the SAS bays may
be populated from 8 and working downwards. Placing a new SAS device into a lower bay number
will cause the hardware paths to change after a new cold-install or recovery session. When you
4
HP Integrity rx2660, rx3600 and rx6600 Servers Errata Additional HP-UX 11i v2 (B.11.23) and 11i v3 (B.11.31) drivers and
patches


...

Dieses Handbuch ist für folgende Modelle:
PC Desktops - HP Integrity rx3600 Server (186.6 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien