Anleitung Tekkeon, modell MP3450 R2
Hersteller: Tekkeon Dateigröße: 226.43 kb Dateiname: UG_MP3450_RevB.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
Connect the Smart 3-Pin Adapter Bracket on to the end of myPower ALL Plus (shown). 2. Connect the 3-Pin end of the Smart 3-Pin Adapter into the bottom row of the 6-Pin Input Port on myPower ALL Plus (shown) and the other end into the solar panel output port. LED turns on while solar panel is charging myPower ALL Plus 3. Verify that the charging indicator next to the input jack on the Smart 3-Pin Adapter (shown) turns on to indicate the battery is charging. 4. After approximately four hours, press the Capacity Display button to view the battery capacity. If the capacity does not indicate full (all blue LEDs on), continue to charge the battery until the battery capacity indicates full. 5. When the battery capacity indicates full, unplug the connected charging cable. Using myPower ALL Plus myPower ALL Plus can be used to power and/or charge up to two portable devices simultaneously. With devices that require higher voltage levels, like laptop computers and portable DVD players, we recommend that you use myPower ALL Plus only to power the device. You will find that powering without charging your higher voltage device will maximize the battery life of myPower ALL Plus, thus letting you use your portable device even longer. To use myPower ALL Plus to power and/or charge your device, take these steps which are described in detail in the following sections. • Select an adapter plug for your main device and connect the plug to the output cord. • Connect the power output cord to myPower ALL Plus. • Slide the Power switch to on. • Adjust the voltage level to match that of your main device. • Connect the adapter plug/output cord to your main device. • Connect a second 5V device Select/Connect the Adapter Plug 1. Select the adapter plug that fits securely into the power jack on your portable device. 2. Locate the polarity symbol on your device in the area around the power connector jack: Center Positive Center Negative WARNING: myPower ALL Plus supports Center Positive polarity only. If your device has a Center Negative polarity, do not power the device with myPower ALL Plus; contact support@tekkeon.com for assistance. 3. Connect the adapter plug to the power output cord (but not the device). If you are using a UA-xxx adapter (rather than PA-xxx), you must insert the PA-L34 (“Z”) adapter that came with your myPower ALL Plus between the adapter cord and UA-xxx adapter as shown. NOTE: If you change the adapter plug while the power adapter cord is connected to myPower ALL Plus, the voltage setting will reset to the lowest voltage, which is the default voltage setting. PA-L34 (“Z”) Adapter for myPower ALL Plus Connect the Power Output Cord 1. Plug the large end of the power output cord into the DC OUT jack on the end of myPower ALL Plus. (If you have previously selected a voltage, the voltage selection will be returned to the lowest setting.) Adjust the Voltage Level 1. Locate the voltage specification for your portable device. This can be found on the device power adapter label or device specification label which typically is found on the bottom of the unit. (If available, use the voltage specification shown on the power adapter.) 2. Slide the power switch to ON. The 5V voltage indicator will turn on to indicate that the voltage is set to the lowest setting. 3. Connect the output cable to the DC OUT port. 4. Press the voltage selector until the voltage indicator for your voltage selection (5, 6, 7.5, 9, 12, 14, 16, 19) turns on. Set the voltage output to the selection that is equal to, or one step lower or higher (whichever is closer) than the voltage identified for your device. For example, if your device requires 6V, set the voltage to 6V. If you device requires 7.2V, set the voltage to 7.5V. The voltage will be automatically locked when the device is connected. The light under the voltage selector will glow to indicate the voltage is locked. (Please note, if the light stops glowing, the voltage has become unlocked.) 5. To change the voltage, disconnect the output cable from the device, and select a new voltage. The voltage will be automatically locked after a device is connected. CAUTION: It is important to set the voltage selector NO MORE than one step higher than the voltage requirement for the portable device as an incorrect setting may prevent myPower ALL Plus from working with your device, or may harm your device in the rare instance that the device accepts the higher voltage. However, for all devices, adjusting the voltage ONLY one step higher than required will not harm the device. Sample Power Adapter Label TIP: You can optimize the use of myPower ALL Plus with your laptop computer or portable DVD player by setting the voltage on myPower ALL Plus to less than the required voltage shown on the laptop computer power supply. This prevents myPower ALL Plus from charging the device, thus extending the amount of time you can use myPower ALL Plus to power your laptop computer. Most laptop computers have a battery volta...