Anleitung AltiGen comm, modell TRITON T1
Hersteller: AltiGen comm Dateigröße: 239.96 kb Dateiname: b984c2ec-1bc5-4c66-ae0b-6a54f9126aad.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
D or higher) • AltiGen’s Triton T1 Board (one or more) • AltiWare OE R3.0 (or higher) • 300W/10A CPU Power (minimum required to power AltiGen boards only) • CSU (Channel Service Unit) # of AltiGen Boards # of Slots** CPU HDD 1 Triton T1, 1-3 Quantum 2 PCI, 3 ISA 233 Mhz 2GB 1 Triton T1, 1-6 Quantum 2 PCI, 6 ISA 300 Mhz 2GB 1-4 Triton T1, 1-10 Quantum 5 PCI, 10 ISA 350 Mhz 4GB # of AltiGen Boards Power Supply** Typical Power Supply 1 Triton T1, 1-3 Quantum +12V: 4.2 Amps +5V: 6Amps 300W/30A@5V/12A@12V 1 Triton T1, 1-6 Quantum +12V: 8.4 Amps +5V: 10.8Amps 400W/40A@5V/16A@12V 1-4 Triton T1, 1-10 Quantum +12V: 14 Amps +5V: 21Amps 400W/40A@5V/16A@12V ** The above system requirements are for AltiGen components only, and do not take into account requirements for othersystem components such as motherboard, disk drives, etc. LED Indicators GREEN LED RED LED Status OFF OFF No power ON OFF Normal operation OFF ON No signal ON Flashing Faulty signal with frame synchronization*** OFF Flashing Faulty signal without frame synchronization Alternating Alternating Frame slips in normal operation *** Faulty signals include the following: yellow alarm, bipolar violation or frame error STEP 1: MAKE SURE BOARD ID OF QUANTUM BOARD(S) IS SET PROPERLY The first (outer-most) Quantum board ID should be set as 0, the next board ID as 1, and so forth. Do not skip slots between boards. Refer to the Quantum Quick Installation Guide for proper installation instructions. CPU STEP 2: INSERT TRITON T1 BOARD(S) INTO PCI SLOTS After installing the Triton T1 Board(s), make sure the Triton T1 board ID isset properly. The first (outer-most) Triton T1 Board should be set at 0, thenext board ID as 1, and so forth. Do not skip slots between boards. The T1 Boards must be set with ID ranges of 0 - 3. If 4 or greater isselected as the Board ID, the board will not function. NOTE! If Triton VoIP Boards are installed, the T1 Board should begin withID of 0 and should be the first (outer-most) boards, followed by the VoIPBoards. Triton Quantum 0 1 CPU 3 2 1 0 STEP 3: CONNECT THE MVIP CABLE AND TERMINATE THE MVIP BUS IMPORTANT! Make sure the MVIP bus is terminated (set to close) at theQuantum Board with ID of 0. All other boards are not terminated (MVIP BusTermination Switch set to OPEN). DO NOT TWIST THE MVIP CABLE. It should lay flat when connected to boards, as shown below. The MVIP Bus is only terminated on one board per system. CPU Board Triton 0 1 CPU 3 2 1 0 STEP 4: CONNECT CSU (CHANNEL SERVICE UNIT) TO TRITON T1 BOARD Quantum MVIP Bus Termination Switch CLOSE OPENCLOSE Using Adtran’s CSU (model T1 CSU ACE) as an example, connect your CSU to the Triton T1 board using on RJ-48C or RJ-48X cable. Then, connect your CSU to your network termination box using an RJ-48C or RJ-48X cable. Power Network Termination Box Central Office Net T1 Line CSU CPE For T1 Socket (RJ-48) Receive Ring = Pin 1 Receive Tip = Pin 2 Transmit Ring = Pin 4 Receive Tip = Pin 5 RJ48c or RJ48c or RJ-48x cable RJ-48x cable For Adtran CSU NOTE: The default settings for the equipment Line Build Out (LBO) and the network LBO are for distances shorter than 133 ft. CAUTION: Switch ON the Manual Loopback (LB) when the equipment connection (from the Triton Board) is not ready. This will give the CO good signal and prevent the CO from switching off service. Switch OFF the Manual LB in normal operation. STEP 6: TURN SYSTEM ON AND INSTALL ALTIWARE OE OR START ALTIWARE OE TO CONFIGURE NEW T1 TRUNKS Please see the following sections in the AltiWare OE manuals for details on how to configure T1 trunks: • System Administration Manual Chapter 3, Board Configuration Chapter 4, Trunk Configuration TECHNICAL SUPPORT • End users, please contact your Authorized AltiGen Dealer. • Authorized AltiGen Dealers, Call AltiGen Technical Support at 1-888-ALTIGEN (258-4436) Send E-mail to: support@altigen.com • Please provide the following information so that the support representative can provide fast service and solution to your problem. Serial #: ________________ AltiWare Release #: _____________ Server HW: CPU _______, Memory _______, Hard Drive _______ # of AltiGen boards installed: Quantum________ Triton ________ Description of the problem: AltiGen Communications, Inc. ©AltiGen Communications, Inc. Rights Reserved. Printed in USA. 9/99 4005-0006-A2 ...