Login:
Stimmen - 2, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Cecilware, modell BC301-IT

Hersteller: Cecilware
Dateigröße: 863.15 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Once the Warmer Timer has expired an alarm is generated. An alarm consists of a blinking warmer LED and (optionally) the audible alarm (buzzer) sounding. The Warmer Timer is reset (restarted) by cycling the warmer Off and On. AUDIBLE ALARM AUDIBLE ALARM ON/OFF Description – The Audible Alarm feature allows the user to enable/disable the buzzer from indicating that the Warmer Timer has expired. WARMER TIME WARMER TIME ### MINUTES Description – The Warmer Time is the length of time that a warmer can be continuously energized before an alarm is generated. WARMER REDUCTION WARMER REDUCTION ON/OFF Description – The Warmer Reduction feature allows the user to gradually reduce the actual heating power of the warmers. This reduction of power is taken over the Warmer Timer period. REDUCTION PERCENTAGE REDUCTION PCT ### % Description – The Reduction Percentage is the percentage of Warmer Power that is gradually reduced over the Warmer Time. WEEKDAY TIMER WEEKDAY TIMER ON/OFF Description – The Weekday Timer function allows the system to automatically turn ON at a specified time and turn OFF at a specified time every weekday (Monday – Friday). WEEKDAY TIME ON WEEKDAY TIME ON ##:## #M Description – The Weekday Time ON function allows the user to set the required weekday turn ON time. 10 WEEKDAY TIME OFF WEEKDAY TIME OFF ##:## #M Description – The Weekday Time OFF function allows the user to set the required weekday turn OFF time. WEEKEND TIMER WEEKEND TIMER ON/OFF Description – The Weekend Timer function allows the system to automatically turn ON at a specified time and turn OFF at a specified time every weekend (Saturday - Sunday). WEEKEND TIME ON WEEKEND TIME ON ##:## #M escription – The Weekend Time ON function allows the user to set the required weekend turn ON time. WEEKEND TIME OFF WEEKEND TIME OFF ##:## #M Description – The Weekend Time OFF function allows the user to set the required weekend turn OFF time. CLOCK SETUP CLOCK SETUP ON/OFF Description – The Clock Setup function allows the user to adjust (set and calibrate) the systems Real-Time- Clock. ADJUST SECONDS ADJUST SECONDS DAY HH:MM:## Description – The Adjust Seconds function allows the user to adjust (set) the systems Real-Time-Clock Seconds placeholder. ADJUST MINUTES ADJUST MINUTES DAY HH:##:SS Description – The Adjust Minutes function allows the user to adjust (set) the systems Real-Time-Clock Minutes placeholder. ADJUST HOURS ADJUST HOURS DAY ##:MM:SS Description – The Adjust Hours function allows the user to adjust (set) the systems Real-Time-Clock Hours placeholder. ADJUST DAY ADJUST DAY ### HH:MM:SS Description – The Adjust Day function allows the user to adjust (set) the systems Real-Time-Clock Day placeholder. CLOCK CALIBRATION CONSTANT CLOCK CAL CONST ## Description – The Clock Calibration Constant function allows the user to calibrate the systems Real-Time- Clock (RTC). Each unit corresponds to approximately five seconds per month. Thus, if the RTC is running five seconds slow per month then the Clock Calibration Constant needs to be increased by one. Conversely, if the RTC is running five seconds fast per month then the Clock Calibration Constant needs to be decreased by one. UNITS UNITS ENGLISH/METRIC Description – The Units function allows the user to select English (oz, °F) or Metric (mL,°C) units of measure. DEFAULT VALUES DEFAULT VALUES ARE YOU SURE ? Description – The Default Values function allows the user to set all system parameters back to their Factory Default Settings. This provides a known (reference) configuration for troubleshooting purposes. DEFAULT VALUES COMPLETED 11 ERROR MODE Description – The main function of Error Mode is report any system malfunctions and to disable the unit The system must be “powered down” using the Power Key located on the membrane keypad to reset any reported error KEYPAD ! SYSTEM ERROR ! KEYPAD Description – This screen is displayed and the unit is disabled when a key-press is detected during the initial application of power to the system. This test is not performed during a Power Key initiated “power-on” sequence. Possible Causes – Membrane Keypad or someone depressing a key while applying power to the system 110/220VAC ON ! SYSTEM ERROR ! 110/220VAC ON Description – This screen is displayed and the unit is disabled when line voltage is detected before the Safety Relay is energized. Possible Causes – Wiring or Safety Relay 110/220VAC OFF ! SYSTEM ERROR ! 110/220VAC OFF Description – This screen is displayed and the unit is disabled when line voltage is not detected after the Safety Relay is energized. Possible Causes – Wiring, Fuse, High Temp Limit Switch, Control Card, or Safety Relay HIGH WATER TEMP ! SYSTEM ERROR ! HIGH WATER TEMP Description – This screen is displayed and the unit is disabled when the present water temperature is sensed as being higher than 208 °F. Possible Causes – Wiring, Power Triac, Control Card, or Water Temperature Sensor OVER FLOW ! SYSTEM ERROR ! OVER FLOW Description ...

Dieses Handbuch ist für folgende Modelle:
Kaffeemaschinen - BC2-IT (863.15 kb)
Kaffeemaschinen - BC302-IT (863.15 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien