Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Cecilware, modell BC240

Hersteller: Cecilware
Dateigröße: 2.09 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBABLE CAUSE REMEDY 1. No power to the machine. a) Loose wire connection. b) Blown fuse. c) Tripped Breaker a) Check wire connections to Power Switch. b) Check fuse. c) Re-set Breaker 2. Machine keeps repeating cycle. a) Dispense Switch defective. a) Replace Dispense Switch. 3. Water does not shut off. Water keeps running into funnel. a) Leaking Water Inlet Valve [Solenoid]. b) Inoperative Switches. c) Clogged Dispense Valve a) Clean/check fittings of Valve. Replace Valve if needed. See ”Water Inlet Valve Test” b) Check Switch connections. Replace it if needed. c) Clean Dispense Valve. Replace Dispense Valve if inoperative. 3. Water will not stop flowing into tank. a) Water Level Probe malfunction. b) Water Inlet Valve malfunction.. a) Check Probe. Replace if necessary. See “Probe Test” b) Check Solenoid. Replace if necessary. See “Water Inlet Valve Test” 4. Water drips from brew funnel. a) Leaking Dispense Valve. b) Too much water in tank. c) Spray Head Fitting is clogged. d) Water Valve blocked by scales. a) Replace Water Dispense Valve. b) Dispense some water from tank. c) Clean Spray Head Fitting. d) Replace or clean Valve Seat. a) Water Inlet Valve (Solenoid) malfunction. b) Water Level Probe malfunction. a) Check Water Inlet Valve. Replace if necessary. See “Water Inlet Valve Test” b) Check Probe. Replace if necessary. See “Probe Test”. 6. Water is not heating up in the water tank. a) Temperature setting is incorrect. b) Loose connection to Heating Element. c) Heater is burned out or defective. a) Set Temperature at 200°F – See Thermostat Adjustments. b) Make sure all wires are tight. c) Replace the Heater. a) Run out of hot water in tank. b) Temperature setting is incorrect. c) Loose electrical connection. d) Bad or burnt out Heating Element. a) Allow time for water in tank to heat after filling. b) Set temperature at 200°F. (See Thermostat Adjustments) c) Check all electrical connections for contact. d) Replace Heater. 8. Coffee too strong. a) Water flow too low. b) Too much coffee in the brew funnel. a) Adjust water flow rate on Dispense Valve. b) Put the proper amount of coffee in funnel. See suggested amount. a) Not enough coffee in the brew funnel. b) Water flow too high. a) Add coffee. b) Adjust water flow rate on Dispense Valve. TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBABLE CAUSE REMEDY 1. No power to the machine. a) Loose wire connection. b) Blown fuse. c) Tripped Breaker a) Check wire connections to Power Switch. b) Check fuse. c) Re-set Breaker 2. Machine keeps repeating cycle. a) Dispense Switch defective. a) Replace Dispense Switch. 3. Water does not shut off. Water keeps running into funnel. a) Leaking Water Inlet Valve [Solenoid]. b) Inoperative Switches. c) Clogged Dispense Valve a) Clean/check fittings of Valve. Replace Valve if needed. See ”Water Inlet Valve Test” b) Check Switch connections. Replace it if needed. c) Clean Dispense Valve. Replace Dispense Valve if inoperative. 3. Water will not stop flowing into tank. a) Water Level Probe malfunction. b) Water Inlet Valve malfunction.. a) Check Probe. Replace if necessary. See “Probe Test” b) Check Solenoid. Replace if necessary. See “Water Inlet Valve Test” 4. Water drips from brew funnel. a) Leaking Dispense Valve. b) Too much water in tank. c) Spray Head Fitting is clogged. d) Water Valve blocked by scales. a) Replace Water Dispense Valve. b) Dispense some water from tank. c) Clean Spray Head Fitting. d) Replace or clean Valve Seat. a) Water Inlet Valve (Solenoid) malfunction. b) Water Level Probe malfunction. a) Check Water Inlet Valve. Replace if necessary. See “Water Inlet Valve Test” b) Check Probe. Replace if necessary. See “Probe Test”. 6. Water is not heating up in the water tank. a) Temperature setting is incorrect. b) Loose connection to Heating Element. c) Heater is burned out or defective. a) Set Temperature at 200°F – See Thermostat Adjustments. b) Make...

Dieses Handbuch ist für folgende Modelle:
Kaffeemaschinen - BC1 (2.09 mb)
Kaffeemaschinen - BC120 (2.09 mb)
Kaffeemaschinen - BC2 (2.09 mb)
Kaffeemaschinen - BC301 (2.09 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien