Login:
heruntergeladen wurde: 0   Dateigröße: 781 kb   Hersteller: Continental  
Kategorie: Kamine
@name

FIGURE 9a-c The fireplace requires a minimum enclosure height of 39”. For temperature requirements, the enclosure space around and above the fireplace must be left unobstructed. W415-0298 / K / 12.06.07 FINISHING HOODGRATE AND LOG INSTALLATION FINISHING HOODGRATE AND LOG INSTALLATION 1. Remove curtain mesh and rod assembly 2. Remove log carton 3. Remove grate from the lower control area (stored there when shipped) 4. Unscrew the 3 screws in the firebox, set grate in place and secure using the 3

heruntergeladen wurde: 1   Dateigröße: 781 kb   Hersteller: Continental  
Kategorie: Kamine
@name

UNVENTED MILLIVOLT SYSTEM INSTALLATION AND OPERATION INSTRUCTIONS FOR UNVENTED GAS FIREPLACE NATURAL GAS MODEL CVF36N PROPANE GAS MODEL CVF36P CERTIFIED FOR UNITED STATES USING ANSI METHODS WARNING: If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SM

heruntergeladen wurde: 1   Dateigröße: 3 mb   Hersteller: Continental  
Kategorie: Kamine
@name

Use supports or equivalent non-combustible strapping to maintain the 1" clearance from combustibles. 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. The venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 2. Slip a 4" diameter length of aluminum flexible liner a minimum of 2" over the inner sleeve of the air terminal. Secure to the sleeve using 3 screws a

heruntergeladen wurde: 13   Dateigröße: 3 mb   Hersteller: Continental  
Kategorie: Kamine
@name

• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building. Installation and service must be performed by a quali

heruntergeladen wurde: 1   Dateigröße: 752 kb   Hersteller: Continental  
Kategorie: Kamine
@name

INSIDE: Attach and secure the flex liners to the vent connection assembly using the same procedure as before, ensuring that the marked exhaust liner is attached to the exhaust collar. FIGURE 3 FIGURE 4 VENT CONNECTOR EXTENSION RESTRICTOR PLATE STUDS FIGURE5a-b 5. Reaching in through the insert, manoeuvre the vent connection assembly through the openings in the firebox top, taking care not to damage the gasket. In case of a low ceiling fireplace, the extension should be removed and reinstalled af

heruntergeladen wurde: 2   Dateigröße: 752 kb   Hersteller: Continental  
Kategorie: Kamine
@name

Immediately call a qualified service technician to inspect the fireplace insert and to replace any part of the control system and any gas control which has been under water. • Do not operate the fireplace insert with the glass door opened, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. • Do not strike or slam shut the fireplace insert glass door. • This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting t

heruntergeladen wurde: 0   Dateigröße: 2 mb   Hersteller: Continental  
Kategorie: Kamine
@name

side of the unit. The recommended maximum lead length depends on wire size: WIRE SIZE MAX. LENGTH 14gauge 100 feet 16gauge 60 feet 18gauge 40 feet Attach the two leads to terminals 1 and 3 located on the gas valve. FIGURE 4 1 2 3 FIGURE 5 Do not connect the gas valve to electricity (110 volts or 24 volts). W415-0120 / E / 01.11.05 UPPER LOUVRES Insert the back edge of the upper louvre into the upper louvre clips. FLUSH LOUVRE KIT, GI-1L FIGURE 8 UPPER LOUVRE LOUVRE CLIP SIDE VIEW LOWER LOUVRES S

heruntergeladen wurde: 5   Dateigröße: 2 mb   Hersteller: Continental  
Kategorie: Kamine
@name

SYMPTOM PROBLEM TEST SOLUTION TROUBLE SHOOTING GUIDE BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED. SYMPTOM PROBLEM TEST SOLUTION Pilot goes out when System is not correctly purged. -purge the gas line with the glass door removed. the gas knob is re- Out of propane gas. -fill the tank. leased. Pilot flame is not large enough -turn up the pilot flame. Pilot flame is not engulfing the -gently twist the pilot head to

heruntergeladen wurde: 6   Dateigröße: 2 mb   Hersteller: Continental  
Kategorie: Kamine
@name

HORIZONTAL AIR TERMINAL INSTALLATION 4. Apply high temperature sealant W5730002 (not supplied) to the outer edge of the of the outside sleeve of the air terminal. Slip a 8" diameter coupler over the sleeve and secure as before. Trim the 8" coupler even with the 5" coupler end. 5. Thread the air terminal pipe assembly down through the roof support and attach, ensuring that a minimum 16" of air terminal FIGURE 29 FIGURE 27 will penetrate the roof when fastened. If the C CCA AAU UUL LLK KKI IIN NNG

heruntergeladen wurde: 7   Dateigröße: 2 mb   Hersteller: Continental  
Kategorie: Kamine
@name

• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fireplace. • Clothing or other flammable material should not be placed on or near the fireplace. • Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies. • Ensure you have incorporated adequate safety measure to protect infants





Kategorien