Anleitung Stovax, modell Linea GAZCO Linea Balanced Flue Convector Fire

Hersteller: Stovax
Dateigröße: 717.57 kb
Dateiname: 9d5dcdc8-2c4f-42fb-bb18-b577a2240a5f.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


7.1 This appliance requires no additional ventilation. 8.1 To assist in any future correspondence, your installer should have completed the commissioning sheet at the front of this book, this records the essential installation details of the appliance. In all correspondence always quote the Model number and Serial number. 9.1 Parts of this appliance become hot during normal use. It is therefore recommended that a suitable fire guard be used for protection of young children and the infirm. Indeed, all parts of the appliance should be treated as a 'working surface' except for the control touch pad area and access panel (Designio version only). 9. HOT SURFACES 8. INSTALLATION DETAILS 7. VENTILATION 6. SERVICING 5. RUNNING IN 4. FLAME FAILURE DEVICE 6 USER INSTRUCTION 7 USER INSTRUCTION 10.1 If the Linea is fitted with a Designio front, access to the batteries can be achieved by simply dropping the lower front access cover. 10.2 If the Linea is fitted with a Plano or Vetro front, access to the batteries can be achieved through the access hole in the casing below the unit. See diagram 4. 10.3 Remove the top from the plastic battery compartment by gently depressing the top in the area with the indication arrow and then sliding off in the direction of the arrow. See diagram 5. 10.4 Replace the batteries with three "C" size cells ensuring they are in the correct orientation as shown in the diagram in the base of the plastic battery holder. 10.5 Replace the top of the battery holder and push back into its location. 10. BATTERY REPLACEMENT FIRE WILL NOT LIGHT 4 Does the pilot spark when using the handset? Does the pilot spark when using the touch pad? Is there any spark at the pilot? Does the appliance go out during use? Does pilot light then go out immediately? Is the low battery indicator visible on the handset display? Change the appliance batteries Change the handset batteries Does it spark only once or twice and very slowly? NO NO NO NO YES NO YES YES YES INSUFFICIENT BATTERY POWER The Copreci control system used on this appliance has a built-in safety feature which will prevent the appliance from lighting if there is insufficient battery power. This feature will also act to turn the appliance off if the battery power falls below a safe level. When the battery power falls to a low level, this is indicated by 10 audible beeps and 10 continuous flashes on the touchpad LED indicator. This will occur when the ignition is activated and the batteries should be replaced. If the appliance will not light, please check the touchpad for this warning before proceeding further. You may notice a noise from the control valve when attempting to light the appliance under these conditions. This is normal and should not cause concern. 5 AR1664 8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS 8651 P8651 Efficiency Class I Flue Outlet Size 100 O / 152mm O Gas Inlet Connection Size 8mm O Wall Thickness - Minimum = 100mm (4") Maximum = 500mm Linea Replacement Batteries - 3 x 'C' Cells Handset Replacement Batteries - 3 x 'AAA' Cells Model Gas Gas Working Aeration Injector Gas Rate Input kW (Gross) Nox Country CAT. Type Pressure m3/h High Low Class Linea NG I2H Natural (G20) 20mbar 2 x 8mm 1.7 0.50 5.25 3.5 4 GB, IE Linea LPG I3P Propane (G31) 37mbar 1.2 0.20 5.25 3.5 4 GB, IE PACKING CHECKLIST Qty Description 1 Linea assembly including fixing bracket 1 Flue Pipe 1 Terminal Guard 1 Remote Hand Set 1 Terminal Guard Fixing Kit Containing: 4 Wood Screws 1 1/4” 4 Red Rawlplugs 1 Linea Fixing Kit Containing: 4 Wood Screws 2 1/2” 4 Brown Rawlplugs 1 Aluminium Tape 1 Sealing Ring 3 ‘C’ Cell Batteries 3 ‘AAA’ Batteries 1 Instruction Manual 1 x 7.5mm 2 x 10mm AR1330 AR1331 9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS NOTE: This appliance can only be installed in conjunction with the flue supplied. 1.1 The flue must be sited in accordance with BS5440: Part 1 (latest edition). See diagram 1. 1.2 Any terminal which is less than 2 metres above any access (level ground, balcony or above a flat roof to which people have access) is to be fitted with a guard. 1.3 The flue must be securely fixed and fire precautions followed in accordance with local and national codes of practice. 1.4 The horizontal terminal can be reduced in size. See diagram 2. 1. FLUE AND CHIMNEY REQUIREMENTS 2 AR0630 1 10 TIMBER FRAMED BUILDINGS 1.5 It will be necessary to provide additional clearance when the flue passes through a wall containing any combustible materials so as to prevent a fire hazard. 1.6 The hole through which the flue will pass, must have a steel sleeve which is positioned so that an air gap of at least 25mm is maintained between the outer surface of the flue, and any part of the sleeve. 1.7 For further guidance on the installation of gas appliances in timber framed buildings, contact your local buildings control authority. 2.1 Before installation, ensure that the local distribution conditions (identification of the type of gas ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien