Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Stovax, modell Brunel P8050

Hersteller: Stovax
Dateigröße: 353.09 kb
Dateiname: ebcfdc4e-ecbb-4b37-bda4-f93b83ac5397.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


2.9 • Secure the spigot extension to the engine assembly and seal with heat resisting tape or similar • Position the engine assembly ensuring the 50mm rear clearance is maintained • Proceed with the installation as detailed in points 2.2 to 2.6 above. 2.10 • Secure the lip plate to the underside of the stove with the two bolts provided. 3. FUELBED ARRANGEMENT 3.1 • Place the white ceramic cover gasket onto the burner • Ensure the holes align with the burner ports, Diagram 5. AR0886 4 AR0899 6 AR0900 7 3.4 • Placethreecoalsequallyspacedontherearofthefuel bed so they touch the rear panel, Diagram 8 AR0898 5 AR0901 8 11 INSTALLATION INSTRUCTIONS INSTALLATION 3.5 • Place five coals on the front of the fuel bed so they rest on the front coal effect and lean against the vertical fingers, Diagram 9 AR0902 9 3.6 • Placetheremainingfourcoalsbetweenthetworowsofcoals • Rotatethecoalstoensuretheyaresecureonthefuelbed, Diagram 10 AR0903 10 3.7 • Closethedoorandtightentheboltanddomednut NOTE: ENSURE THAT THE COALS ARE POSITIONED, AS DETAILED ABOVE. ONLY USE THE CORRECT AMOUNT OF COALS, AS SPECIFIED IN THE DIAGRAMS 4. LIGHTING 4.1 Full instructions are given in the User Section of this manual 12 INSTALLATION INSTRUCTIONS COMMISSIONING 1. COMMISSIONING 1.1 • Close all openable doors and windows in the room • Ignite the stove and operate on maximum for 10 minutes AR0539 1 If there is any doubt, run the stove for a further 10 minutes, and repeat the test. 1.2 If there are any extractor fans in adjacent rooms, the test must be repeated with the fans running on maximum and interconnecting doors open. IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE AND SEEk EXPERT ADVICE. For future reference record the installation details on the Commissioning Sheet page 3 of these instructions. 13 SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations. 1.1 Before any test are undertaken on the appliance, conduct a gas soundness test for the property to ensure that there are no gas leaks prior to starting work. 1.2 Before any tests are undertaken on the applaince it is also recommended to fully check the operation of the appliance. 1.3 Special checks 1.3.1 Clean any lint or fluff from the pilot - pay particular attention to the aeration hole in the side of the pilot 1.3.2 Clean away any fluff or lint from under the burner 1.3.3 Check that the spark gap on the pilot is correct 1.4 Correct any faults found during the initial tests and then re-commission the appliance conducting the usual safety checks. 1.5 Advise the customer of any remedial action taken. AR0097 3.5mm15mm IGNITION FUNCTIONAL CHECk 1PILOT WILL NOT LIGHTEnsure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark, clean the area. Operate the valve. Is there a spark? Consult Section 2 and retry. Check alignment of pilot burner head, change the ignition lead, see diagram 1 on page 17. Check isolation tap and gas meter, retry. Correct and retry. Purge the gas pipes and retry. SEE 'NO SPARk' CHART SYSTEM Ok There is a blockage in the system, check the inlet test point, the mag seating, valve and pilot filter. Is the gas turned on to the appliance? Is the gas pressure correct? Has the system got any air in it? Does the pilot light? Is the control being operated correctly? Will the pilot light with a match? No Yes NoYesNoYesYesNo NoYes NoNo YesYes 14 FLAME FAILURE FUNCTIONAL CHECkIGNITION FUNCTIONAL CHECk 2IGNITION FUNCTIONAL CHECk 2 NO SPARK PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE 15 Ensure there is no debris around the pilot assembly, (e.g. coal, soot etc.) which could short the spark, clean the area. Consult Section 2, retry. Operate the valve to light the pilot, does the valve 'click'? Is the pIlot burner horizontal? See diagram 1 on page 17Has ignition lead become detached or is connection poor? Remove the electrode lead from electrode with insulated pliers. Hold the tip 4mm from the pilot pipework, is there a spark when the valve ‘clicks’? Is the electrode wire detached from the piezo in the valve? Replace the combined lead and piezo, retry. Correct and retry. Check for defective or damaged control knob spindle or cam operation. Check for correct location of piezo components. Correct and retry. Remove the electrode lead from the piezo. Operate the valve. Does a spark jump from the piezo to the valve body? Is the valve being operated correctly? Reset the pilot burner. Yes YesYesNoNoNo YesYes Yes NoNo Replace the electrode. Replace the electrodelead and retry. Replace the piezo and gas valve and retry. Yes No Ensure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark, clean the area. Light the pilot and keep the control knob pushed in at least 10 seconds before letting go. With the pilot Will pilot stay...

Dieses Handbuch ist für folgende Modelle:
Kamine - Brunel 8050 (353.09 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien