|
Anleitung Zusammenfassung
7.9 Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four dome nuts and tool supplied. Do not overtigthen the nuts, see diagram 10. NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED. USER INSTRUCTIONS 5 AR1613 6 AR1614 7 AR1615 8 AR1616 9 AR1617 10 AR0540 8. THE FLAME FAILURE DEVICE 8.1 This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple. 9. ‘RUNNING IN’ 9.1 The surface coating on your GAZCO fires will "burn off" during the first 24 hour of use, producing a harmless and temporary odour. This will disappear after the short period of use. If the odour persists, ask your installer for advice. 10. SERVICING 10.1 The fire must be serviced every 12 months by a qualified Gas Engineer. In all correspondence, always quote the appliance type and serial number, which may be found on the data badge. 11. INSTALLATION DETAILS 11.1 To assist in any future correspondence, your installer should have completed the commissioning sheet at the front of this manual. This records the essential installation details of this appliance. In all correspondence always quote the Model No. and Serial No. 7 USER INSTRUCTIONS 8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS: ASHDON - 8546LUC - P8546LUC / 8544LUC - P8544LUC CLARENDON - 8545LUC - P8545LUC / 8547LUC - P8547LUC Model Gas Gas Working Aeration Injector Gas Rate Input kW (Gross) Country CAT. Type Pressure m3/h High Low 8545LUC-8547LUC I2H Natural 20 mbar O 1 x 14.5 375 0.600 6.4 3.6 GB, IE 8546LUC-8544LUC (G20) P8545LUC-P8547LUC I3P Propane 37 mbar O 2 x 12 165 0.221 6.15 3.6 GB, IE P8546LUC-P8547LUC (G31) Rear Exit Flue Wall Thickness: Min Max 200mm 550mm Efficiency Class I Flue Outlet Size 100 O / 152mm Gas Inlet Connection Size 8mm O RESTRICTOR REQUIREMENT Vertical & Horizontal Flue Specification Vertical Flue Height from Top of Appliance Horizontal Length Restrictor Size 500mm up to 1490mm 250mm up to 1000mm No Restrictor 1500mm up to 3000mm 250mm up to 5000mm 75mm O TOP EXIT - VERTICAL ONLY INCLUDING OFFSET Vertical Flue Height from Top of Appliance Restrictor Size 3000mm up to 4990mm 52mm O 5000mm up to 1000mm 47mm O Packing Checklist Qty Description 1 Stove 1 Flue Blanking plate 1 Coal Retainer 1 Log set (5 logs)* 1 Ash Panel* (2 Sections) 1 Fixing Kit Containing 1 Instruction Manual 1 Wood Screw 1 Rawplug 1 Box spanner *Packed in appliance A B C D E F ins mm ins mm ins mm ins mm ins mm ins mm 353/4 654 253/4 652 173/4 440 201/2 520 61/4 158 3 75 1 AR1618 9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS NOTE: This appliance can only be installed in conjunction with the flue supplied. 1.1 The flue must be sited in accordance with BS5440: Part 1 (latest editon). See diagram 1. 1.2 Any terminal which is less than 2 metres above any access (level ground, balcony or above a flat roof to which people have access), is to be fitted with the guard. 1.3 All vertical and horizontal flues must be securely fixed and fire precautions followed in accordance with local and national codes of practice. 1.4 A restrictor may be required. Refer to Technical Specifications on previous page. 1.1 TIMBER FRAMED BUILDINGS 1.5 It will be necessary to provide additional clearance when the fire passes through a wall containing any combustible materials so as to prevent a fire hazard. 1.6 The hole through which the flue will pass, must have a steel sleeve which is positioned so that an air gap of at least 25mm is maintained between the outer surface of the flue, and any part of the sleeve. 1.7 For further guidance on the installation of gas appliances in timber framed buildings, contact your local buildings control authority. NOTE: ATTENTION MUST BE GIVEN TO ALLOWING ADEQUATE CLEARANCE AT THE SIDES AND REAR OF THE STOVE, TO PROVIDE ACCESS FOR SERVICING. 1 AR0602 10 1.2 REAR FLUE 8526 Terminal dimensions: 395 x 200 x 200 mm (H x W x D) Cut to length as required on site. Guard Supplied. 1.3 TOP EXIT Two types of top exit flue terminal are available, horizontal and vertical. For a horizontal terminal, decide on the terminal position and measure the height from the top of the appliance to the centre of the required hole. For minimum and maximum flue dimensions see diagram 3. Access must be either above or at the side of the installation to allow the flue to be assembled on top of the appliance. When a horizontal terminal is used, the vertical sections are assembled first, then the 90-degree elbow and finally the horizontal section including the terminal. If a masonry installation is to be built, a suitable lintel must be used to support the opening. Only the horizontal terminal section can be reduced in size. Refer to Balanced Flue Technical Information for details of flue length. 1.4 TOP FLUE UP & OUT KIT (8523/8523AN) Verti...
Dieses Handbuch ist für folgende Modelle:Kamine - Clarendon & Ashdon 8544LUC-P8544LUC (2.8 mb)
Kamine - Clarendon & Ashdon 8547LUC-P8547LUC (2.8 mb)
Kamine - Clarendon & Ashdon ASHDON 8546LUC-P8546LUC (2.8 mb)