Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Majestic Appliances, modell 360DVS2

Hersteller: Majestic Appliances
Dateigröße: 2.98 mb
Dateiname: a9c15c78-0ac9-49ff-b8df-a71245cc26b0.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. 360DVS Series Direct Vent Fireplaces Fireplace Dimensions - 360DVS2 CK G Electrical.. Access Gas Line.. Access J J Rear Vent Configuration H E H IJ B F J K K D A K J Electrical.. Access Gas Line.. Access J A E I Electrical.. Access Gas Line.. Access K J J Top Vent Configuration H E H J G B F J K K D A K J C Electrical.. Access Gas Line.. Access J A E Fig. 1a Fireplace specifications—360DVS2 Appliance Dimensions Ref. Rear Vent Configuration Top Vent Configuration A 38...” (968 mm) 38...” (968 mm) B 43...” (1099 mm) 43...” (1099 mm) C 24” (610 mm) 24” (610 mm) D 24” (610 mm) 24” (610 mm) E 37...” (949 mm) 37...” (949 mm) F 35...” (911 mm) 35...” (911 mm) G 30...” (775 mm) 7” (178 mm) H 12” (305 mm) 12” (305 mm) I 3...” (80 mm) 3...” (80 mm) J 2...” (70 mm) 2...” (70 mm) K 1...” (33 mm) 1...” (33 mm) 360 DVS Series Direct Vent Fireplaces Fireplace Dimensions - 360DVS3 / 306DVSL / 360DVSR I JK K B E G F H H B Electrical.. Access Gas Line.. Access CK J J Rear Vent Configuration ROD C D A I JK K B E F H H B Electrical.. Access Gas Line.. Access K J J G Top Vent Configuration C D A Fig. 1b Fireplace specifications—360DVS3/ 360DDVSL/ 360DVSR Appliance Dimensions Ref. Rear Vent Configuration Top Vent Configuration A 38...” (968 mm) 38...” (968 mm) B 40...” (1032 mm) 40...” (1032 mm) C 24” (610 mm) 24” (610 mm) D 24” (610 mm) 24” (610 mm) E 37...” (949 mm) 37...” (949 mm) F 35...” (911 mm) 35...” (911 mm) G 30...” (775 mm) 7” (178 mm) H 12” (305 mm) 12” (305 mm) I 3...” (80 mm) 3...” (80 mm) J 2...” (70 mm) 2...” (70 mm) K 1...” (33 mm) 1...” (33 mm) 360DVS Series Direct Vent Fireplaces Framing Dimensions - 360DVS2 Rear Vent Configuration ROD ROW ROH CFM121 Top Vent Configuration ROD ROW ROH CFM122 Fig. 2a Fireplace framing dimensions—360DVS2 Framing Dimensions Ref. Rear Vent Configuration Top Vent Configuration ROD 24” (610 mm) minus two times finishing material thickness to be even with face of unit. ROH 38...” (981 mm) Not to be framed until unit is set in place, due to 3...” (79 mm) allowance for flue collar ROW Not to be framed until unit is set in place due to 3...” (79 mm) allowance for flue collar 43...” (1111 mm) 360 DVS Series Direct Vent Fireplaces Framing Dimensions - 360DVS3 / 360DVSL / 360DVSR ROWROD ROH ROH ROH ROD 360DVSL 360DVS/3/L/R 360DVS3 Rear Vent Confiration ROD 360DVSR CFM123 ROD ROH ROW ROH ROH ROD 360DVSL 360DVS/3/L/R 360DVS3 Top Vent Configuration ROD 360DVSR CFM124 Fig. 2b Fireplace framing dimensions—360DVS3/ 360DVSL/ 360DVSR Framing Dimensions Ref. Rear Vent Configuration Top Vent Configuration Model 360DVS3 360DVSL/R 360DVS3 360DVSL/R ROD (See Note 1) (See Note 2) (See Note 1) ( See Note 2) ROH 38...” (981 mm) Not to be framed until unit is set in place, due to 3...” (79 mm) allowance for flue collar ROW 40...” (1032 mm) minus one time (1x) finishing material thickness to be even with face of unit. NOTE 1: 24” (610 mm) minus two times (2x) finishing material thickness to be even with face of unit. NOTE 2: 24...” (629 mm) minus one time (1x) finishing material thickness to be even with face of unit. 360DVS Series Direct Vent Fireplaces Fig. 3 Locating your gas fireplace Locating Your Fireplace X X X Y Y Y Z A A B LU584-2 A Wall Location (Fig. 3) Y (Minimum distance between a glass panel and a parallel wall) = 3’ (914mm) Z (Minimum distance between edge of a glass panel and an adjacent wall) = 3” (76mm) B Island Location (Fig. 3) X (Maximum length of horizontal venting) = 20’ (6.1m) Refer to the venting section in this manual for specific dimensions. Clearance to Combustibles Top of unit to ceiling................................. 36” (914 mm) Front of unit to combustibles ................... 36” (914 mm) Appliance Top .........................................0” (0 mm) to standoff Bottom..................................................... 0” (0 mm) Vent End ....................... 1/2” (13 mm) to rear panel Nonvent End (DVS2) .............................. 0” (0 mm) Venting Concentric sections of DV Vent: Top, bottom & sides .............................. 1” (25 mm) Nonconcentric sections of DV Vent: Side and bottom.................................... 1” (25 mm) Top ........................................................ 2” (51 mm) Mantels The height at which a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel leg (if so fitted) and the fireplace. For correct mounting height and width, refer to Fig. 4a and 4b and the Mantel Chart below. The fitting of a bay window trim kit does not affect the distances and reference points referred to in the diagram and chart. Noncombustible mantels and legs ma...

Dieses Handbuch ist für folgende Modelle:
Kamine - 360DVS3 (2.98 mb)
Kamine - 360DVSL (2.98 mb)
Kamine - 360DVSR (2.98 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien