Anleitung Hampton Direct, modell H35-NG1

Hersteller: Hampton Direct
Dateigröße: 4.84 mb
Dateiname: Hampton_h35_install.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Inc. Hampton® H35 Direct Vent Freestanding Gas Stove INSTALLATION ROTATING 45O ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS 1)Remove all 4 screws that secure 2) Rotate the elbow 180o the elbow to the unit using a 1/4" magnetic nut driver. 3) Secure the elbow by securing it with the 4 screws. Remove all 4 screws and washers VENTING ARRANGEMENTS Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical runs with horizontal terminations. Maximum one 90O elbow (two 45o elbows equal one 90o elbow). Propane and Natural Gas: Residential, Manufactured and Mobile Homes Installations The venting arrangements diagrammed below, have a min. of 75% (flue loss) efficiency with Fan Off, as required for manufactured homes. (Actual efficiency may be as high as 85%) May be installed in Manufactured (Mobile) Homes after first sale. NOTE: See "Vent Restrictor Position" section for installation instructions for the Vent Restrictor Position. Vertical Terminations Systems for Residential Manufactured and Mobile Homes The shaded area in the diagram below shows all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum two 45o elbows. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles. May be installed in Manufactured (Mobile) Homes after first sale. Offset to Vertical Terminations Hampton® H35 Direct Vent Freestanding Gas Stove INSTALLATION VENTING ARRANGEMENTS HORIZONTAL TERMINATIONS USING RIGID PIPE The two diagrams show all allowable combinations of straight horizontal termination using Rigid Pipe. Restrictor position "A". Dura-Vent Snorkel Termination Riser Vent Termination Venting Arrangements -Straight Horizontal Termination at a De-Rated BTU The diagrams show all allowable combinations of straight horizontal termination using Rigid Pipe. Restrictor position "A". Refer to the "Conversion Kit to Lower BTU Rating" section for de-rating instructions. Dura-Vent Snorkel Termination Riser Vent Termination *If this is an outside corner, the minimum distance between the vent and the outside corner is 6” (15cm). See “F” on the diagram in the "Exterior Vent Terminal Locations" section. Hampton® H35 Direct Vent Freestanding Gas Stove INSTALLATION Horizontal Venting with Two (2) 90o Elbows One 90o elbow = Two 45o elbows. Option V H + H1 With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 8 feet total horizontal. Please note minimum 1 foot between 90o elbows is required. A) 3' Min. 2' Max. B) 4' Min. 3' Max. C) 5' Min. 4' Max. D) 6' Min. 5' Max. E) F) 7' Min. 8' Min. 6' Max. 8' Max. Lengths do not include elbow indicated Vent restrictor position A (fully open), refer to the "Vent Restrictor Position" section. H H1 V Horizontal Venting with Two (2) 90o Elbows One 90o elbow = Two 45o elbows. Option H V H + H1 With these options, max. total pipe length is 30 feet with min. of 9 feet total vertical and max. 8 feet total horizontal. Please note min. 1 foot between 90o elbows is required. A) 1' Max. 2' Min. 3' Max. B) 2' Max. 3' Min. 5' Max. C) 3' Max. 5' Min. 6' Max. D) 4' Max. 7' Min. 7' Max. E) 5' Max. 9' Min. 8' Max. Lengths do not include elbow indicated Vent restrictor position A (fully open), refer to the "Vent Restrcitor Postion" section. H1 H V Hampton® H35 Direct Vent Freestanding Gas Stove INSTALLATION Vertical Venting with Two (2) 90o Elbows One 90o elbow = Two 45o elbows. Option V H V + V1 With these options, max. total pipe length is 30 feet with min. of 6 feet total vertical and max. 7 feet total horizontal. Please note min. 1 foot between 90o elbows is required. A) 1' Min. 3' Max. 2' Min. B) 2' Min. 4' Max. 3' Min. C) 3' Min. 5' Max. 4' Min. D) 4' Min. 6' Max. 5' Min. E) 5' Min. 7' Max. 6' Min. Lengths do not include elbow indicated Vent restrictor position A (fully open), refer to the "Vent Restrcitor Postion" section. V1 VH Vertical Venting with Two (2) 90o Elbows One 90o elbow = Two 45o elbows. Option H + H1 V With these options, max. total pipe length is 30 feet with min. of 6 feet total vertical and max. 6 feet total horizontal. Please note min. 1 foot between 90o elbows is required. A) 2' Max. 2' Min. B) 3' Max. 3' Min. C) 4' Max. 4' Min. D) 5' Max. 5' Min. E) 6' Max. 6' Min. Lengths do not include elbow indicated Vent restrictor position A (fully open), refer to the "Vent Restrcitor Postion" section. H1 H V Hampton® H35 Direct Vent Freestanding Gas Stove 18 Hampton® H35 Direct Vent Freestanding Gas Stove Venting Arrangements - Vertical Terminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagram shows the allowable vertical terminations. Note: Must remove 4 screws from stove collar and rotate 180o to have collar facing straight back. Secure into place with 4 screws. VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANC...

Dieses Handbuch ist für folgende Modelle:
Kamine - H35-LP1 (4.84 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien