Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Southwest Specialty Products, modell Sonoran Unvented 48

Hersteller: Southwest Specialty Products
Dateigröße: 450.7 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). 6” (side) 12” GAS LINE INSTALLATION NOTE: This section is intended as a guide for qualified technicians installing gas to this Unvented Fireplace. GAS LINE HOOK-UP SHOULD BE DONE BY YOUR GAS SUPPLIER OR A QUALIFIED SERVICE PERSON. NOTE: BEFORE YOU PROCEED, BE SURE YOUR GAS SUPPLY IS OFF! A gas line may be installed for use with a decorative gas appliance, available through your local distributor. Use only 1/2-inch black iron pipe and appropriate fittings. When installing a gas line, a shut-off valve designed for installation outside the fireplace is recommended. Installation procedure: 1. Remove the knockout indentation on the refractory (or firebrick) wall, located approximately 2 inches above the refractory hearth floor. To remove, pry knockout (inside fireplace) with a chisel, screwdriver or sharp object until knockout is released. Use . “ masonry drill bit to remove remaining firebrick. Remove fragmented portion of refractory. 2. Remove gas line cover plane on right- or left-hand side of fireplace (depending on which way incoming gas line is routed to the fireplace). Pull out insulation from gas line sleeve. 3. Run a 1/2-inch NPT black iron gas line into the fireplace 8 1/2 inches from the floor, and route into the fire chamber through the gas line sleeve. (If using a raised platform, add height of platform to specified 8 1/2 inches.) Provide sufficient gas line into fireplace chamber for fitting connection. NOTE: Secure incoming gas line to wood framing to provide rigidity for threaded end. 4. Re-pack insulation around gas line and into sleeve openings. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement. Either install decorative gas appliance (per instructions included with appliance) or cap off gas line. CAUTION: All gas piping and connections must be tested for leaks after installation is complete. With gas turned ON, apply a soap and water solution to all connections and joints. If bubbles appear, leaks can be detected and corrected. DO NOT USE AN OPEN FLAME FOR LEAK TESTING. DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. The gas pipe is only intended for connection to a decorative gas appliance that 1) incorporates an automatic shut-off device, and 2) complies with the Standard for decorative gas appliances for Installation in Vented Fireplaces, ANSI Z21.60-1 990. The gas pipe must be installed in accordance with the National Fuel Gas code, ANSI Z223.1-1992. FINISHING THE FIREPLACE FIREPLACE FACING Any non-combustible material may be used for facing (glass, tile, brick, etc.), as long as proper clearances are maintained (refer to section on clearances), and fireplace openings are not blocked or obstructed in any way. Use only heat-resistant, non-combustible mortar or adhesive to secure facing material to front of fireplace. When placing facing at the upper edge of the effective opening of the fireplace, install an "U' shaped piece of metal extending the full width of the opening. Secure metal with sheet metal screws at a distance high enough from the edge as to not interfere with the operation of the doors. This ensures that the facing material over time should not block the opening if it were to lose cohesion. OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS When lit for the first time, the Unvented Fireplace will omit a slight odor for about an hour or two. This is a normal occurrence which is due to the "curing" of logs and "burn-in" of internal paints and lubricants used in the manufacturing process. Keep control compartment, logs, burners, and area surrounding the logs clean by vacuuming or brushing at least twice a year. Temporary removal of the log set may ease the cleaning of the burner and pilot assembly. In cleaning, take care not to alter the settings on the pilot assembly. The firebox canopy must not be modified or replaced with a canopy that may be provided with the unvented decorative room heater. THE LOGS CAN GET VERY HOT!! HANDLE ONLY WHEN COOL. IMPORTANT-. Turn off gas and remote wall switch before servicing appliance. Any safety screen or guard removed for servicing must be replaced prior to operating the appliance. Installation and repair should be done by a qualified person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. "WARNING: Any change to this heater or its controls can be dangerous." FOR LIGHTING AND OPERATING THIS UNVENTEDFIREPLACE, PLEASE REFER TO THE UNVENTED GAS LOGS MANUFACTURER'S INSTRUCTION MANUAL. Never ...

Dieses Handbuch ist für folgende Modelle:
Kamine - Sonoran Unvented 36 (450.7 kb)
Kamine - Sonoran Unvented 42 (450.7 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien