Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Monessen Hearth, modell N/PSC7

Hersteller: Monessen Hearth
Dateigröße: 3.98 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:
Kamine - N/PSC7 (6.77 mb)en

Anleitung Zusammenfassung


Log placement log placement Figure 63 1. Place rear log (#1) on grate assembly. Log should rest firmly on the two log mounting pins shown. 2. Place top right log (#2) on the rear log. Rest the right back side of the log in the flat area of the rear log. Place the narrow front end of the log next to the center vertical grate bar. 3. Place the top left log (#3) on the rear log. Nest the forked end of the top left log into the fork or the rear log. Rest the narrow end of the top left log behind the center vertical grate bar. lava rock and ember placement Sprinkle lava rock on the floor of the inner combustion chamber. Evenly distribute the rock. Do not pile the lava rock up in front of grate. Do not place lava rock on the burner. If desired, purchase optional embers to decorate the floor of the fireplace. LG637CDV logs Top Right Log, #2 Top Left Log, #3 Rear Log, #1 Flat Area Log Mounting Pins Log Mounting Pins Left Vertical Grate Bar Center Vertical Grate Bar Figure 63 - Log Placement LG637 Right Vertical Grate Bar WARNING Do not sprinkle the lava rock or ember chunks on top of the burner. This may cause potential sooting, glass breakage and a fire hazard cleaning and maintenance Thermocouple WARNING FP1943pilot flame Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. Thermopile Burner, Pilot and Control Compartment Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times. Pilot Flame The flames from the pilot should be visually checked as soon as the heater is installed and periodically during normal operation. The pilot flame must always be present when the fireplace is in operation. Figure 64. The pilot flame has three distinct flames, one engulfing the thermopile, one engulfing the thermocouple or sensor, and the other reaching to the main burner. burner Inspect area around the injector. Remove any lint or foreign material with a brush or vacuum. Millivolt Control Pilot FP1943 Sensor FP2453hooded pilot flames Thermopile Signature Command System Pilot Figure 64 - Pilot Flame Burner Flame The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation. In normal operation, at full rate, and after operating for about 15 to 30 minutes, the flame should be yellow and slightly taller than the rear log. Figure 65 If the flame is blue and only in the center, turn off unit and let cool. After unit is cool, remove logs and check to make sure rock wool is placed correctly. Replace logs. NOTE: The type of installation, vent system configuration, and wind effects may cause the flame patterns to vary. FP2453 LG638CDV7 Figure 65 - Burner Flame Appearance LG638 cleaning and maintenance Vent System The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function. Glass Door Thoroughly clean the inside of the glass door after using the fireplace for ten hours. Periodically clean the glass door as necessary. When cleaning the glass, remember: • Do not remove the glass when hot. Allow glass to cool before removal. • NEVER use abrasive materials. • Keep children and pets a safe distance away. • Never operate the fireplace without the glass door properly secured. • Never operate the fireplace if the glass is broken. • Replace any glass that is chipped, cracked, or broken. Replacement glass door assemblies MUST be supplied by the fireplace manufacturer – No substitute materials may be used. • Handle glass door with care to avoid striking or scratching it on hard objects. To clean glass door, follow “Glass Removal” procedure outlined in the Final Installation section. Film deposit on the inside of the glass should be cleaned off using a nontoxic, non-corrosive, non-abrasive, mild-cleaning solution. Simply apply an adequate amount to the glass and wipe off with a damp cloth. After all maintenance has been completed, re-install glass door. Logs Leave logs installed in the fireplace for cleaning. Vacuum surface of the logs with a brush attachment. If logs must be removed for cleaning, handle carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. Vacuum surface of logs with brush attachment or brush logs with a soft bristle brush (i.e. clean, dry paintbrush). To place logs back in the fireplace, Refer to “Log Placement” section in this manual. NOTE: Do not use fluids to clean ceramic fiber logs. Rock wool Replace or add rock wool as required ...

Dieses Handbuch ist für folgende Modelle:
Kamine - CDV7 (3.98 mb)
Kamine - CDVR33N/PV7 (3.98 mb)
Kamine - N/PE7 (3.98 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien