Secure in place using the four dome nuts and the tool supplied, do not over tighten the nuts, see diagram 22. Keep the tool with these instructions for future use. NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED OR WHEN THE GLASS IS BROKEN. 22 AR0390 7. GAZCO FLUE SURE SYSTEM 7.1 The stove is fitted with the Gazco Flue Sure System, which will act to cut off the gas supply to the burner in the event of incorrect operation of the flue. If the system acts to cut off the gas supply, this indicates that there is insufficient flue pull. If this occurs a minimum of 10 minutes should be allowed before trying to relight. Continued operation of this safety device means there may be a serious problem with the flue system. A qualified gas engineer should inspect this. Do not use the stove until an engineer says it is safe to do so. 8. THE FLAME FAILURE DEVICE 8.1 This is a safety feature incorporated in all GAZCO fires, which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple. 9. 'RUNNING IN' 9.1 The surface coating on your GAZCO stove will ‘burn off’ during the first 24 hours of operation on high, producing a harmless and temporary odour. If the odour persists ask your retailer for advice. 10. SERVICING 10.1 A qualified gas engineer must service the stove every 12 months. In all correspondence, always quote the appliance type and the Serial Number found on the data badge on the appliance. 11. VENTILATION 11.1 Any purpose provided ventilation should be checked periodically to ensure it is free from obstruction. 12. INSTALLATION DETAILS 12.1 To assist in any future correspondence, your installer should have completed the Appliance Commissioning Checklist in this manual. This records the essential installation details of this appliance. In all correspondence always quote the Model No. and Serial No. 13. HOT SURFACES 13.1 Parts of this appliance become hot during normal use. It is recommended that a suitable fire guard be used for protection of young children and the infirm. Indeed, all parts of the appliance should be treated as a ‘working surface’ except for the control area. 9 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Model CAT. Gas Gas Type Working Pressure NOX Class Aeration Injector Gas Rate m3.h Input kW (Gross) Country High Low Small: 8560 - Marlborough 8573 - Stockton I2H Naural Gas G20 20 mbar 5 o7 mm 260 0.433 4.55 Gross 2.5 Gross GB,IE P8560 - Marlborough P8573 - Stockton I3+ LPG Propane G31 LPG Butane G30 37 mbar 29 mbar 5 o13 mm 120 0.173 0.131 4.60 Gross 2.5 Gross GB,IE Medium: 8564- Marlborough 8574 - Stockton I2H Naural Gas G20 20 mbar 5 o11 mm 375 0.639 6.60 Gross 3.25 Gross GB,IE P8564 - Marlborough P8574 - Stockton I3+ LPG Propane G31 LPG Butane G30 37 mbar 29 mbar 5 o15.5 x 2 170 0.237 0.18 6.30 Gross 3.25 Gross GB,IE Large: 8568- Marlborough I2H Naural Gas G20 20 mbar 5 o13 mm 560 0.848 8.90 Gross 4.0 Gross GB,IE P8568- Marlborough I3+ LPG Propane G31 LPG Butane G30 37 mbar 29 mbar 5 o15.5 x 2 o13.0 x 1 240 0.35 0.266 9.30 Gross 4.0 Gross GB,IE Efficiency Class II Flue Outlet Size 127 mm (5”) o Gas Inlet Connection Size 8 mm o Minimum flue specification T260/N2/O/D/1 Maximum flue temperature 180°C Packing Checklist Qty Description 1 Stove 1 Flue Blanking plate 1 Flue In fill plate 1 Coal set* 1 Flame Baffle* 1 Front Coal* Marlborough A B C D E F 1 Fixing kit containing 1 Instruction Manual 2 Wood screws 2 Rawlplugs 1 Box spanner Stockton *Packed in appliance A B C D E F ins mm ins mm ins mm ins mm ins mm ins mm Small 161/8 410 21 533 11 280 137/8 352 43/8 111 31/8 80 Medium 231/4 590 23 583 13 330 153/4 401 4 101 31/8 80 Large 283/4 675 243/4 628 133/8 340 171/2 446 4 101 31/8 80 A B C D E F Small Medium A B C D E F ins mm ins mm ins mm ins mm ins mm ins mm 165/8 422 205/8 525 111/2 290 135/8 346 43/8 110 2 50 223/4 579 243/16 618 135/8 345 163/4 425 4 102 25/8 66 10 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force, and must be a minimum of 127mm in diameter. (5"). 1.2 The minimum height of the flue or chimney must be 3 metres (10ft). Any horizontal flue run from the rear outlet should not exceed 100mm from the back of the appliance. 1.3 The chimney or flue must be free from any obstruction. Any damper plates should be removed or secured in the fully open position and no restrictor plates should be fitted. 1.4 The chimney should be swept prior to the installation of the appliance, but where it can be seen that the chimney is clean and unobstructed throughout its entire length, it need not be swept. NOTE: If it is intended to fit the stove into an existing brick- built chimney without a closure plate*, a 5" (127mm) liner must be used. Larger lined flues may work, but in some instances could cause cold start flue problems resulting in nuisance shutdown. Lined flues above 7" (175mm) are not recommended. Due to recent changes to European chimney sta...

Dieses Handbuch ist für folgende Modelle:
Kamine - 8564 (965.64 kb)
Kamine - 8574 (965.64 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien