Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Quadra-Fire, modell 810-03201

Hersteller: Quadra-Fire
Dateigröße: 5.63 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


•The liner must be securely attached to the insert flue collar and the chimney top. •The air flow of the factory-built zero-clearance fireplace system must not be altered. The flue liner top support attachment must not reduce the air flow for the existing air-cooled chimney system. •No dilution air is allowed to enter the chimney. 1. Secure the fireplace damper in the open position. If this cannot be accomplished, it will be necessary to remove the damper 2. Seal damper area of chimney around chimney connector with a high temperature sealant or seal insert against the face of the fireplace. 3. Both methods must be removable and replaceable for cleaning and re-installation. THIS FIREPLACE MAY HAVE BEEN ALTERED TO ACCOMMODATE AN INSERT. IT MUST BE RETURNED TO ITS ORIGINAL CONDITION BEFORE USE AS A SOLID FUEL BURNING FIREPLACE. 250-2061 • The fireplace must not be altered, except for the exceptions listed below. Do not removal the bricks and mortar from the existing fireplace. The following modifications are premissible: • Removal of damper or locked in open position • Removal of smoke shelf or baffle • Removal of ember catches • Removel of fire grate • Removal of view screen/curtain • Removal of doors • External trim pieces which do not affect the operation of the fireplace may be removed providing they can be stored on or within the fireplace for reassembly if the insert is removed. • The permanent metal warning label provided must be attached to the back of the fireplace, with screws or nails, stating that the fireplace may have been altered to accommodate the insert, and must be returned to original condition for use as a conventional fireplace. Figure 11.1 • If the hearth extension is lower than the fireplace opening, the portion of the insert extending onto the hearth must be supported. • Manufacturer designed adjustable support kit can be ordered from your dealer. • Final approval of this installation type is contingent upon the authority having jurisdiction. NOTE: Refer to chimney liner manufacturer for recommendations on supporting the liner. Installation into fireplaces without a permit will void the listing WARNING! Risk of Fire! Follow venting manufacturer’s clearances and instructions when installing venting system. NOTICE: In Canada when using a factory-built chimney it must be safety listed, Type UL103 HT (2100oF) [1149oC] CLASS “A”or conforming to CAN/ULCS629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS. Page 12 250-7251G August 20, 2009 Figure 121 R Castile Pellet Insert 4Vent Information A. Chimney and Exhaust Connection 1. Chimney & Connector: Use 3 or 4 inch (76-102mm) diameter type "L" or "PL" venting system. It can be vented vertically or horizontally. 2. Mobile Home: Approved for all Listed pellet vent. If using the 3 inch (76mm) vertical Top Vent Adapter Kit or the 3 to 6 inch (76-152mm) Top Vent Offset Adapter, use Listed double wall flue connector. A Quadra-Fire Outside Air Kit must be used with manufactured home installations. 3. Residential: The 3 inch (76mm) vertical Top Vent Adapter Kit and the 3 to 6 inch (76-152mm) Top Vent Offset Adapter are tested to use 24 gauge single wall flue connector or Listed double wall flue connector to Class A Listed metal chimneys, or masonry chimneys meeting International Conference of Building Officials (ICBO) standards for solid fuel appliances. 4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. 5. Secure exhaust venting system to the appliance with at least 3 screws. Also secure all connector pipe joints with at least 3 screws through each joint. 6. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. 7. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. NOTE: All pipe must be welded seam pipe whenever possible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only). Do not put silicone inside of pipe. NOTE: If burning shelled field corn, you must use approved venting specifically designed for corn. Follow the instructions from the venting manufacturer. B. Venting Termination Requirements CAUTION Do not terminate vent in any enclosed or semi-enclosed area such as a carport, garage, attic, crawl space, under a sun deck or porch, narrow walkway or closely fenced area, or any location that can build up a concentration of fumes such as a stairwell, covered breezeway, etc. 1. Termination must exhaust above air inlet elevation. It is recommended that at least 60 inches (1.5m) of vertical pipe be installed when appliance is vented directly through a wall. This will create a natural draft, which will help prevent the possibility of smoke or odor venting into the home during a power outage. It will also keep exhaust from causing a nuisance or hazard by exposing people or shrubs to high temperatures. The safest and preferred venting method is to extend the vent vertically through the roof. 2. Distance from doors and opening windows, or gravity or ventilation air inlets into b...

Dieses Handbuch ist für folgende Modelle:
Kamine - 810-02901 (5.63 mb)
Kamine - CASTINS-CSB (5.63 mb)
Kamine - CASTINS-CWL (5.63 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien