Login:
Stimmen - 2, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Majestic Appliances, modell BR36

Hersteller: Majestic Appliances
Dateigröße: 1.31 mb
Dateiname: 282b2f85-cff2-4754-9e89-67d6fd21d5b7.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If this is constructed of any combustible material it must be within the safe zone indicated in Figure 23. 14 7412944 Majestic Fireplaces® BR/BC Series 12" (305mm) Max. ......" 12" (305mm) Max. 12" (305mm) Min. 1......" (38mm) * 12" (305mm) Min. 1......" (38mm) 6" (159mm) Min. 12" (305mm) Max. 12" (305mm) Min. 1......" (38mm) 6" (159mm) Min. Mantel Clearance - Radiant Model - No Noncombustible Facing Material Combustible Mantel and Trim Finished Wall Header Standoff Noncombustible Material Radiant Surround Face Fireplace Opening * Minimum width from top of sur- round to bottom of screen rail Combustible Mantel and Trim Finished Wall Header Standoff Noncombustible Material Radiant Surround Face Fireplace Opening Mantel Clearance - Radiant Model - with Noncombustible Facing Material Combustible Mantel and Trim Finished Wall Header Standoff Noncombustible Material Circulating Surround Face Fireplace Opening Noncombustible Facing Material Mantel Clearance - Circulating Model 2 x 4 Stud Finished Wall Must be sealed with non- combustible material Fireplace Front Top View FP531a Fig. 21 Mantel clearances. 1..." Ref. Combustible materials are permitted within a shaded area shown in Figure 23 titledMinimum Wall Clearances. * ** MA81 *12" from top of fireplace opening for radiant models 12" from top of grille opening for circulating models **6" from top of fireplace opening for radiant models (Noncombustible material must seperate the black face surround of the fireplace from any combustible mantel material) 6" from top of grille opening for circulating models Face Plate Fig. 22 Combustible mantel clearances. 7412944 15 Majestic Fireplaces® BR/BC Series Side Wall Protection Hearth Installation Adjacent combustible side walls that are within minimum dimensions shown in Figure 23 of the fireplace opening must be protected with CFM Corporation Wall Shield Model SP40 or a specifically built wall shield described in Figure 20. The special wall shield design described in Figure 20 is an alternate method of adding protection to side walls and can be used in place of the SP40 with the same wall clearances specified for the SP40. Rt must =1.85 minimum. Examples of wall shield insulation: 1. Manville - CERAFORM 126, K=.27, 1/2 inches thick 2. CFM Corporation - EH2416, K = .458, 1 inch thick required. A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for minimum dimensions and mounting detail. NOTE: Hearth Extension must not cover the air inlet opening of a fireplace. The hearth extension described in Figure 23 must be a durable noncombustible material with a minimum (total) Rt value of 1.09; see Figure 24 for examples. The overall height (above a combustible floor), depth and width must be as indicated, with the extension centered to the fireplace opening. The top of insulation must be covered with a noncombustible decorative covering or a piece of .018” minimum sheet metal, to protect hearth extension material. (Fig. 23) Secure the hearth extension to the floor to prevent shifting, using trim molding or other similar means at three (3) outer edges. Seal crack between the fireplace hearth and hearth extension with a noncombustible material. (Figs. 23 and 25) Minimum Wall Clearances WITH Noncombustible Surround Facing WITHOUT Noncombustible Surround Facing Minimum Hearth Extension Dimensions (for On-Site Construction) GH G J Seal cracks between the fireplaceand hearth extension with noncombustible material Safety stripsmust overlap ......" minimum May installnoncombustible decorative coveringOR .018" min. sheet metal FireplaceHearth Combustible Floor Minimum Insulation Value "R" 4" MIN. Firebox Opening A -Min. clearance to combustible perpendicular wall B -Min. clearance to combustible perpendicular wall whenusing noncombustible wall shield* Side Wall Side Wall F** C** EE D 4" Brick (Example material) Combustible material permitted within shaded area. * Noncombustible wall shield requires 1" CFM Corporation EH2416 insulation (minimum R Value = 1.85) between decorative noncombustible rigid covering and combustible wall. Minimum height and width is 40" x 40". ** Dimension/degree of angle will vary depending on thicknessof noncombustible surround facing. 4" Shaded area starts 1/2" away fromedge of unit FP594 A B C D E F G H J BR/BC36 16" 12" 48° 41° 18" 14" 9" 16" 48" 406 mm 305 mm 457 mm 356 mm 229 mm 406 mm 1219 mm BR/BC42 20" 12" 42° 35° 18" 14" 12" 20" 61..." 508 mm 305 mm 457 mm 356 mm 305 mm 508 mm 1562 mm Fig. 23 Combustible side wall protection and hearth extension dimensions. 16 7412944 Majestic Fireplaces® BR/BC Series WARNING: HEARTH EXTENSION MUST BE INSTALLED IN ACCORDANCE WITH FIGURE 23 AND MUST NOT COVER THE BOTTOM FRONT OPENING OF THE CIRCULATING MODEL. Alternate noncombustible materials may be used providing the (total) thermal resistance (Rt value) of the alternate material employed is greater than or equal to R = 1.09 Thermal resistance (R) or thermal con...

Dieses Handbuch ist für folgende Modelle:
Kamine - BC36 (1.31 mb)
Kamine - BC42 (1.31 mb)
Kamine - BR42 (1.31 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien