Hersteller: Majestic Appliances
Dateigröße: 367.85 kb
Dateiname: 1e722fc6-9df3-4f76-8e08-eb40b4643473.pdf
|
Anleitung Zusammenfassung
• If control knob does not pop up when it is released, stop and immediately call Rheem service, your local service technician or your gas supplier. • If after several attempts, the pilot will not stay lit, turn the gas control knob to OFF and call Rheem service, your local service technician or gas supplier. 11. Replace the glass door. 12. Turn the gas control knob to the ON position. 13. For the RN/RP models turn the remote control ON/OFF switch to the ON position or set the thermostat to the desired setting. 14. Turn on electrical supply. To Turn Off the Heater 1. Turn the remote control ON/OFF switch to OFF or set the thermostat to the lowest setting. 2. Turn off power supply to the appliance if a service is to be performed. 3. Open louvre assembly bottom. 4. Push in gas control knob slightly and turn clockwise to OFF. Do not force this knob. 5. Close control access panel. RFSDV34 Operating Instructions The comfort control valve (Fig 6) allows remote control of temperature, fan and flame appearance. To access the REMOTE/LOCAL switch on the comfort control valve; open the control door assembly, then remove the upper left and right hand screws on the control panel. Pull the panels forward to expose the gas valve. The REMOTE/LOCAL switch is located on the top of the gas valve. NOTE: The antenna should hang in free air away from grounded metal. Operation 1. If the manual switch is in the REMOTE position, switch it to LOCAL. 2. Turn the pilotstat knob anticlockwise from the OFF to the PILOT position, push the knob down and hold it in position. The pilot valve is now open and allows gas to flow to the pilot burner. 3. Push the plunger on the piezo ignitor until the pilot burner is lit. When the pilot burner is lit the LED on the control will come on after approximately 40 seconds and will provide 1 short blink continuously in the normal mode. When the light turns off, which will be approximately 10 seconds after it has been continuously red, the receiver valve is fully powered. 4. Release the knob (the shaft will move upward). The pilot light should stay lit. If the pilot burner goes out, repeat step 2. 5. Turn the knob anticlockwise to the ON position. If the manual switch is in the LOCAL position (step 1), the main burner will come on immediately. 6. Upon initial use of the remote control, a recognition operation is required between the receiver/valve and remote control. Change the switch from LOCAL to REMOTE . Press the fan or flame button on the remote control within 30 seconds. The LED will blink indicating the remote control will now work with the receiver valve. If the switch continues in the REMOTE position, the remote control will now control the main valve, flame modulation level and fan control. 7. If the manual switch is in the LOCAL position, the valve will be at the highest fixed pressure setting and the fan will be at the highest fixed speed. The remote control will control the fan speed only. Fig. 6 Comfort Control Valve Shut Off Procedure If the manual switch is in the REMOTE position, the remote control can shut off the main burner and fan. However, if the control is still ON a command from the remote control can turn on the main burner or fan. To shut off the system, turn the pilotstat knob clockwise to the OFF position. This action closes the main gas and safety valves. The remote control cannot turn on the main burner or fan. Remote Control Operation Refer to Fig 7 OFF Mode In the OFF mode, the fireplace flame and fan are off, the display will show OFF and display the room temperature. If the receiver is in the REMOTE mode, the fireplace will shut off. ON Mode (Manual) In the ON mode, the room temperature, flame and fan levels will be shown. MANUAL will appear next to both the flame and fan icons. When the control is in the ON mode, you can change the flame and fan levels and the delay timer with the Up and Down buttons. To change the flame level, press the Flame button followed by an arrow key. To change the fan level, press the Fan key followed by an arrow key. Pushing the arrow key once changes the level by one unit Fig.7 Transmitter diagram Delay Timer Mode The shut off delay timer maximum setting is 2 hours and minimum setting is zero minutes. To change the timer level, press the timer key, then the arrow key. Each key press changes the setting by 10 minutes. Auto Mode In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons. With the control in AUTO mode, the main burner turns ON or OFF or modulates based on the heating differential needed to maintain the set temperature. The flame level adjusts automatically to optimize the heat output required to maintain the set temperature. To change the set temperature, press the UP or DOWN key. Each key press changes the setting by one degree. In the AUTO mode, the fan speed increases with increased fan height and decreases with the decreased fan height. “...
Dieses Handbuch ist für folgende Modelle:Kamine - RFSDV34RFNAU (367.85 kb)
Kamine - RFSDV34RFNAU (367.85 kb)
Kamine - RFSDV34RFPAU (367.85 kb)