Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Hearth and Home Technologies, modell GO24MTCH

Hersteller: Hearth and Home Technologies
Dateigröße: 5.18 mb
Dateiname:

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


• Range hoods. • Combustion air requirements for furnaces, water heaters and other combustion appliances. • Clothes dryers. • Location of return-air vents to furnace or air conditioning. • Imbalances of the HVAC air handling system. • Upper level air leaks: recessed lighting, attic hatch opening, duct leaks. WARNING Asphyxiation Risk This appliance produces carbon monoxide (CO). • The free opening areas (in square inches) of the chimney damper as shown in the following tables must be met. • User must make sure damper is locked open. • The installer is responsible to ensure proper ventilation of flue gases before appliance is used. Fire needs to draft properly for safe operation. Table 1 for Factory Built Fireplaces Free Opening Area (in square inches) of Chimney Damper for Venting combustion Products from Decorative Appliances for Installation in Solid Fuel Burning Fireplaces. Chimney Ht. (Feet)* GO318 GO 24 & 324 GO 30 & 330 10 not approved not approved not approved 15 38.5 38.5 45.4 20 31.2 31.2 37.4 25 27.3 27.3 31.2 30 24.6 24.6 28.3 35 22.1 22.1 25.5 40 20.4 20.4 23.8 Table 2 for Masonary Built Fireplaces Free Opening Area (in square inches) of Chimney Damper for Venting combustion Products from Decorative Appliances for Installation in Solid Fuel Burning Fireplaces. Chimney Ht. (Feet)* GO318 GO 24 & 324 GO 30 & 330 6 64 64 71.4 8 59.7 59.7 66.9 10 54.3 54.3 60.2 15 48.8 48.8 54.1 20 44.4 44.4 49.1 30 40.3 40.3 44.5 * Height is measured from the hearth to the top of the chimney. Minimum height is 6 ft. Table 3 for Minimum Fireplace Dimensions Log Set Front Opening Depth Height Rear Width Natural BTU GO24 32 in. 20 in. 18 in. 21 in. 73,000 GO30 38 in. 20 in. 18 in. 27 in. 80,000 GO318 32 in. 23 in. 22 in. 21 in. 77,000 GO324 34 in. 23 in. 22 in. 22 in. 86,000 GO330 40 in. 23 in 22 in. 29 in. 86,000 H. Inspect the Appliance and Components • Remove the contents from the carton labeled “Burner”. Attached to the burner are tags identifying the manufacturer name, serial number, model number (including gas log size), BTU ratings, gas type, etc. • Review the attached tags before proceeding. Ensure that all minimum fireplace dimension requirements are achieved using Table 3. See Figure 1. Ensure the gas type provided in the fireplace coincide with the gas type marked on the tag. • The burner is assembled with the controls installed at the factory and is designed to connect one end of the 3/8 in. supply line before placing inside the fireplace. Ensure the connection is tightened using a 3/4 in. wrench. • Place the burner towards the rear and center of the fireplace and connect to the gas line. Follow instructions in “F. Gas Pressure” to check for gas leaks. Figure 4 Placing Vermiculite .Pour vermiculite over the sand in the pans until they are full. See Figure 4. Note: For best results, do not pack down the rock wool. The placement of rock wool can have an effect on flame pattern and may need to be adjusted to achieve a desired appearance. Figure 1 Measure Firebox Figure 5 Placing Rock Wool • Lightly place dime-size pieces of rock wool evenly on top of the sand and vermiculite to achieve a glowing ember effect. See Figure 5. I. For Natural Gas Installation • Pour sand into the burner pans to the point where the burner pipe is covered. See Figure 3. Level the sand from right to left to ensure an even flame pattern. At this point the pan should be half full. • Remove the Platinum Bright Embers™ from the package. For optimum performance peel each piece apart in layers and lightly place on top of the vermiculite and rock wool where the flame is blue. This will achieve the desired realism. • The gas burns at the point of the least resistance. In case of an uneven flame pattern it may be necessary to adjust the materials in the pans (using an object such as a screwdriver) to achieve the desired effect. • Place desired amount of lava granules on the floor of the fireplace. DO NOT ALLOW THE GRANULES TO COME IN CONTACT WITH THE FLAMES. (Lava granules may contain moisture which, when heating, may cause it to pop out during installation and set-up.) Ensure the controls and switches are unobstructed after the granules are installed. • Place logs. See Sections L Thru S. • Place accent logs around burner on floor of fireplace. Figure 3 Sand A spillage test must be made before the installed appliance is left with the consumer. • Close all doors and windows in the home. • Light the log set (see Lighting Instructions). • After three minutes, test with a smoke match, smoke candle, stick incense or cigarette 1 in. below the top of the opening (lintel) moving across the full width. If spillage (smoke down into the room) occurs, it will most likely be near the top, outside corners. Fire Risk Explosion Risk Personal Injury Risk Failure to position the parts in accordance with the diagrams provided with the log packages or failure to use only parts approved with this appliance may result in K. Inspect the Venting System The fireplace ...

Dieses Handbuch ist für folgende Modelle:
Kamine - GO318MTCH (5.18 mb)
Kamine - GO330MTCH (5.18 mb)
Kamine - GO30MTCH (5.18 mb)
Kamine - GO324MTCH (5.18 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien