|
Anleitung Zusammenfassung
ELECTRICAL WIRING DIAGRAM Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes. If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing location must be followed. 5 MAINTENANCE OF MOTORS The motors used on the fan and flame generator assembly are prelubricated for extended bearing life and require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended. WARNING: Make sure that the power is turned off before proceeding. GLASS INFORMATION 1. Under no circumstances should this product be operated with missing or broken glass. 2. Do not strike or slam the glass. 3. Do not use abrasive cleaners to clean the glass. 4. Replacement glass is available from the manu facturer and replacement should be carried out by a qualified service person. ELECTRICAL WIRING DIAGRAM Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes. If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing location must be followed. 6 Operating Instructions This section provides easy step by step instructions for operating your fireplace. 1. Make sure the unit is unplugged from the power source. 2. Plug the fireplace into a 10AMP/220V outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1900 watts. To access the controls, open the bottom of the fireplace at the front of the unit (see Figure A). A. MAIN ON/OFF SWITCH The on/off switch supplies power to all fireplace functions (heater/flame). B. HEATER THERMOSTAT CONTROL To adjust the temperature to your needs, turn the thermostat control completely clockwise to turn on the heater. When the room reaches the desired temperature, turn the thermostat knob counter clockwise until you hear a click. Leave it in this position to maintain the room temperature at this setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on. To turn the heater off, switch the HEATER ON/OFF SWITCH to the OFF position. C. HEATER ON/OFF SWITCH The HEATER ON/OFF SWITCH supplies power to the heater fan and the heater element. NOTE: When switched ON, the heater fan will operate. The heater element may or may not be on, depending on the thermostat control setting (see “HEATER THERMOSTAT CONTROL”). When the HEATER/FAN pilot light is lighting, it indicate that the heater is on. Warning: During any service of this appliance, the power to the unit must be turned off. It is not acceptable to use the “ON/OFF”switch to meet this requirement. (Refer to operating instruction section) D. INSTRUCTIONS FOR POWER This heater is for use on 220 volts only. The green/yellow grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available. Operating Instructions This section provides easy step by step instructions for operating your fireplace. 1. Make sure the unit is unplugged from the power source. 2. Plug the fireplace into a 10AMP/220V outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1900 watts. To access the controls, open the bottom of the fireplace at the front of the unit (see Figure A). A. MAIN ON/OFF SWITCH The on/off switch supplies power to all fireplace functions (heater/flame). B. HEATER THERMOSTAT CONTROL To adjust the temperature to your needs, turn the thermostat control completely clockwise to turn on the heater. When the room reaches the desired temperature, turn the thermostat knob counter clockwise until you hear a click. Leave it in this position to maintain the room temperature at this setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on. To turn the heater off, switch the HEATER ON/OFF SWITCH to the OFF position. C. HEATER ON/OFF SWITCH The HEATER ON/OFF SWITCH supplies power to the heater fan and the heater element. NOTE: When switched ON, the heater fan will operate. The heater element may or may not be on, depending on the thermostat control setting (see “HEATER THERMOSTAT CONTROL”). When the HEATER/FAN pilot light is lighting, it indicate that the heater is on. Warning: During any service of this appliance, the power to the unit must be turned off. It is not acceptable to use the “ON/OFF”switch to meet this requirement. (Refer to operating instruction section) D. INSTRUCTIONS FOR POWER This heater is for use on 220 volts only. The green/yellow grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-...
Dieses Handbuch ist für folgende Modelle:Kamine - V50TYLA-BC (4.79 mb)
Kamine - V50TYLA-C (4.79 mb)
Kamine - V50TYLA-DO (4.79 mb)
Kamine - V50TYLA-O (4.79 mb)