See Accessories, page 16. Figure 7 -Gas Connection * Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 14. ** 11” W.C. pressure is the minimum inlet pressure for purpose of input adjustment. WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas. gauge hook up. NPT tap must be upstream from heater (see Figure 7). controls. If sediment trap is not installed or is installed incorrectly, heater may not run properly. CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting into gas piping and/or fittings. NG MODELS: 5” to 10.5” W.C. Gas supplier provides external regulat- or for natural gas. Figure 6- External Regulator With Vent Pointing Down Figure 5-Gas Regulator Location and Gas Line Access Into Stove Cabinet Purchase INSTALLATION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG(3.5kPa) 1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator. 2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either using compressed air or opening propane/LP supply valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks immediately. 6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. Figure 8 -Equipment Shutoff Valve WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks immediately. Pressure Testing Heater Gas Connections 1. Open equipment shutoff valve (see Figure 8). 2. Open gas supply valve. 3. Make sure heater is in the OFF position. 4. Check all joints from equipment shutoff valve to control valve (see Figure 9). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks immediately. 6. Light heater (see Operating Heater, page 10 ). Check all other internal joints for leaks. 7. Turn off heater (see To Turn Off Gas to Appliance, page10 ). CAUTION: Make sure external regulator has been installed between natural gas supply and heater. See guidelines under Connecting to Gas Supply, page 8. Test Pressures Equal To or Less Than 1/2 PSIG ( 3.5 kPa ) 1. Close equipment shutoff valve (see Figure 8). 2. Pressurize supply piping system by either using compressed air or opening gas supply tank valve. 3. Check all joints from gas meter to equipment shutoff valve (see Figure 9). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 4. Correct all leaks immediately. Figure 9 -Checking Gas Joints 9 INSTALLATION Continued INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams may result in property damage or personal injury. CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to HIGH, check to see if flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot. IMPORTANT: Make sure log does not cover any burner ports (see Figure10). Figure 10 -Installing Log Set (Top View) OPERATING HEATER FOR YOUR SAFETY . READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by control system, When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS LIGHTING INSTRUCTIONS SEE WARNING in Page 1 for proper instructions. 1. STOP! Read the safety information, page 3. C. Use only your hand to push in control 2. Make sure equipment shutoff knob. Never use tools. If the the appli ance could not operate , don't try to re pair it, Call a qualified service technician or gas supplier.Forced or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. TO TURN OFF GAS TO APPLIANCE Shut off heater 1. Press the IGN/OFF button.(see fig 12) 2. Set the Switch on OFF location.(see fig 11) Shutting off burner only( pilot stay lit) 1.Press the BURNER to set flame ...

Dieses Handbuch ist für folgende Modelle:
Kamine - EL250RYLB-O (602.65 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien