Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Empire Comfort Systems, modell PV-28SV50-BN

Hersteller: Empire Comfort Systems
Dateigröße: 4.33 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor. HEATER INSTALLATION FOR DIRECT VENT Locating Wall Opening The recommended location for this furnace is on an outside wall. Locate wall studs so that wall vent opening will be located between wall studs. The wall opening required for venting is a 3 1/2” (89 mm) minimum diameter opening. Refer to Figures 3 and 6 for positioning the heater on wall and for locating gas line connection and vent opening. Furnace can sit on the floor. 19/16” 4 3/32” Figure 2 22618-17-0308 Page 9 CLEARANCES FOR SINGLE FLUE 1. Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close enough to a 115 VAC wall receptacle to properly power appliance. 2. When facing the front of the furnace, the minimum clearances from casing to combustible construction are 0” (0 mm) on top, 0” (0 mm) on each side, recommend 4” (102 mm) for servicing and 0” (0 mm) from the floor and 2” (51 mm) to rear wall for servicing and installation. 3. The minimum distance from the center of the vent cap to the nearest outside corner or obstruction is 12” (305 mm). The bottom of the exhaust vent terminal and the air intake shall be located at least 12” (305 mm) above grade and must be vented outside. WARNING: The nearest point of the vent cap should be a minimum horizontal distance of six (6) feet (1.83 m) from any pressure regulator. In case of regulator malfunction, the six (6) feet (1.83 m) distance will reduce the chance of gas entering the vent cap. Installation on Rugs and Tile If this appliance is to be installed directly on carpeting, tile, or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is primarily for rugs that may be extremely thick and light-color tile that can discolor. HEATER INSTALLATION FOR SINGLE FLUE Locating Wall Opening The recommended location for this heater is on an outside wall (the unit can be located on an inside wall but must not exceed 40’(12.19 m)inexhaustventlength).Locatewallstudssothatwallventopening will be located between wall studs. The wall opening required for venting is a 1 7/8” (48 mm) minimum diameter opening. Refer to Figures 3 to 6 for positioning the heater on wall and for locating gas line connection and vent opening. Heater can sit on the floor. Page 10 22618-17-0308 22618-17-0308 Page 11 SPECIFICATIONS Heater with Pedestal and Single Flue Adaptor 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (required) Figure 3 Page 12 22618-17-0308 SPECIFICATIONS - (continued) Figure 4 Heater without pedestal 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (required) 22618-17-0308 Page 13 SPECIFICATIONS - (continued) Figure 5 Fireplace Insert with Mantel Surround with Slim Top Panel 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (Required) 6 Surround Model #PVE-1 7 Top Cover Kit, Slim Model #PV2H Caution: Do not block louver in surround. Note: Verify fireplace opening dimensions using Figure 9, page 15. Page 14 22618-17-0308 SPECIFICATIONS - (continued) Figure 6 Fireplace Insert with Mantel Surround with Short Top Panel 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (Required) 6 Surround Model #PVE-1 8 Top Cover Kit, Short Model #PV4H Caution: Do not block louver in surround. Note: Verify fireplace opening dimensions using Figure 9, page 15. 22618-17-0308 Page 15 CLEARANCE TO COMBUSTIBLES Freestanding Models Freestanding Units A Rear Wall to Heater 0” (2” Single Flue and 1 1/4” Direct Vent for Serviceability) B Side Wall to Heater 0” (4” recommended for serviceability) C Corner Installation 0” D Mantel Clearance See Figure 11 Fireplace Insert Note: The Mantis Power-Vent High-Efficiency Fireplace has been tested and approved for zero clearance to combustible materials. Empire Comfort Systems, Inc. recommends that clearances as listed above should be maintained to allow for removal of the product for servicing. C C A B B Figure 7 Figure 8 Single Flue Requires surround for combustion air. Do not cover surround louver. Figure 9 Mantel and Ceiling Clearances Figure 11 Direct Vent Installation Shown Single Flue requires surround for combustion air. Figure 10 12” 18” 24” 8” 6” 4” COMBUSTIBLE TRIM AND MANTELS ALLOWED IN SHADED AREA 40” CEILING ROUGH F...

Dieses Handbuch ist für folgende Modelle:
Kamine - BP)-1 (4.33 mb)
Kamine - CP (4.33 mb)
Kamine - GN (4.33 mb)
Kamine - GP)-1 (4.33 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien