Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung CFM Corporation, modell A125

Hersteller: CFM Corporation
Dateigröße: 1.62 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


sembly. adjustment knob located near the center of the gas control. (Figs. 19 or 20) ........ Turn counterclockwise to decrease flame height Turn clockwise to increase flame height Honeywell Valve 12 10002964 Gas Fireplace Insert First FiringFlame Characteristics It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the Figure 21 and Figure 22 or 23. If any of the flames appear abnormal call a service person. 10002964 pears within a few minutes of burning. .................................................. Figure 23 A125 LG480 .................................................. Figure 23 A132 LG482 3/8" - 1/2" SIT Pilot PSE Pilot F584-703 Fig. 21 Correct pilot flame appearance. Upon completing the gas line connection, a small amount of air will be in the lines. When first lighting unit with pilot light, it will take a few minutes to purge themselves of this air. Once the purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lightings of the heater will not require such purging. When lit for the first time, the appliance will emit a slight odor for awhile. This is due to paint and lubricants used in the manufacturing process. After each lighting, vapor may condense and fog the glass; this moisture disap Gas Fireplace Insert Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING instructions. • If you cannot reach your gas supplier, call the Fire Department C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion. D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any fireplace • Do not touch any electric switch • Do not use any phone in your building • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Lighting Instructions 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level. 4. Open control access panel. 5. Push in gas control knob slightly and turn clockwise to "OFF". 10. Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step. 7. Remove glass door before lighting pilot. (See Glass Frame Removal section). 8. Visibly locate pilot by the main burner. 9. Turn knob on gas control counterclockwise to "PILOT". • If knob does not pop up when released, stop and immediately call your service technician or gas supplier. • If after several tries, the pilot will not stay lit, turn the gas control knob to " " and call your service technician or gas supplier. 11. Replace glass door. 12. Turn gas control knob to “ON” position. 13. For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting. 14. Turn on all electrical power to the fireplace. Euro SIT SIT NOVA Honeywell PILOTON OF F ON PILOT OFF OFF 3 4 5 1 2OFF Pilot 3/8" - 1/2" To Turn Off Gas To Heater 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. Turn the On/Off switch to "OFF" position or set the thermostat to lowest setting. 2. Turn off all electric power to the fireplace if service is to be performed. 14 10002964 Gas Fireplace Insert Troubleshooting the Gas Control System SIT NOVA 820 Millivolt Valve NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. WARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or...

Dieses Handbuch ist für folgende Modelle:
Kamine - A132 (1.62 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien