Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Napoleon Fireplaces, modell GDI-30N

Hersteller: Napoleon Fireplaces
Dateigröße: 629.18 kb
Dateiname: b61a655d-b1cd-40ab-a30b-b8d91cb4eed2.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


• Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly. 1. Stop! Read the above safety information on this label. 2. Turn off all electric power to the fireplace. 3. Turn the gas knob clockwise to off. 4. Wait five (5) minutes to clear out any gas. If you smell gas including near the floor. Stop! Follow "B" in the above safety information on this label. If you don't smell gas go the next step. 5. Find pilot located in front of back log. 6. Turn gas knob counter-clockwise to pilot. 2. Push in gas control knob slightly and turn clockwise to off. Do not force. 1. Turn off all electrical power to the unit if service is to be performed. WHAT TO DO IF YOU SMELL GAS: FOR YOUR SAFETY READ BEFORE LIGHTING: LIGHTING INSTRUCTIONS TO TURN OFF GAS FLAME ADJUSTMENT KNOB OTPILLOIHTPILONOFFO PILOT ON/OFF KNOB MAINTENANCE TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE INSERT! CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. This insert and its venting system should be inspected before use and at least annually by a qualified service person. The fireplace area must be kept clear and free of combustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed. 1. In order to properly clean the burner and pilot assembly, remove the logs exposing both assemblies. 2. Keep the control compartment, logs, burner, air shutter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year. 3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly. 4. Check to see that the pilot flame is large enough to engulf the thermocouple on one leg and reaches toward the burner on the other leg. 5. Replace the cleaned logs. 6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5-10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer/distributor. 7. Check that the door gasketing is not broken or missing. Replace if necessary. Remove the pilot screw cap. Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow. Replace the pilot screw cap. Natural gas has the air shutter set at 1/4" opening; propane has the air shutter set at 3/8" opening. Closing the air W415-0384 / D / 09.13.05 10 W415-0384 / D / 09.13.05 FIGURE 9 BLOWER ACCESS COVER 1. Turn off the electrical power and the gas supply to the fireplace insert. 2. Open the glass door and remove the logs and fibre bricks, if installed. 3. Remove the blower access cover held on with 4 screws. 4. Remove the blower mounting plate with the blower attached. NOTE: Check the blower gasket for damage. Replace if shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. FIGURE 12 Air shutter adjustment must only be done by a qualified gas installer! FIGURE 14 The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be established. ADJUSTMENTS PILOT BURNER ADJUSTMENT VENTURI ADJUSTMENT FIGURE 13 PI PI PILOT SCREW LOT NO LOT HI LO FF O damaged. 5. Disconnect the two blower wires. Remove the blower from the mounting plate and replace. For thermodisc replacement: Remove the mounting bracket secured to the underside of the burner base. Remove the thermodisc from the bracket and replace. 6. Reconnect the two wires. Re-install the blower gasket. Reattach the blower mounting plate and blower access cover. Replace the logs. Close the fire viewing door. 7. Turn the gas supply and electricity back on. Because the blower is thermally activated, when turned on, it will automatically start approximately 5-15 minutes after lighting the fireplace insert and will run for approximately 30-45 minutes after the fireplace insert has been turned off. Use of the fan increases the output of heat. Drywall dust will penetrate into the blower bearings causing irreparable damage and must be prevented from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy. BLOWER REPLACEMENT INSTALLATION FIGURE 11 THERMODISC / BRACKET ASSEMBLY FIGURE 8 red white black BLOWER ACCESS COVER REMOVED MOUNTING PLATE FIGURE 10 11 REPLACEMENTS Contact your dealer for questions concerning prices and When ordering replacement parts always gi...

Dieses Handbuch ist für folgende Modelle:
Kamine - GDI-30P (629.18 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien