Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Napoleon Fireplaces, modell GI 3600-N

Hersteller: Napoleon Fireplaces
Dateigröße: 2.25 mb
Dateiname: f83efab2-f967-4b13-80f7-2f860debf458.pdf

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf Steel Ltd. dealer. Do not substitute materials. Clean the glass after the first 10 hours of operation with a recommended gas fireplace glass cleaner. Thereafter clean as required. Do not clean glass when hot! If the glass is not kept clean permanent discolouration and / or blemishes may result. W415-0061 / B / 01.11.05 FIGURE 1 INSTALLATION Clean out ashes from the inside of the wood-burning fireplace. Make sure that the chimney and wood-burning fireplace are in a clean and sound condition and constructed of non-combustible materials. If necessary have any repair work done by a qualified person before installing the insert. Remove the existing fireplace damper or lock into an open position. Using screws, attach the fireplace warning tag (W385-0199) to the inside of the firebox of the fireplace into which the insert is being installed. WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY THE AUTHORITY HAVING JURISDICTION. ATTENTION: CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES AYANT JURIDICTION. W385-0199 The sheet-metal parts of the fireplace, in which the gas fireplace insert is to be installed, must not be cut. If the wood-burning factory-built fireplace has no gas access hole(s) provided, an access hole of 1. inch or less may be drilled through the lower sides or bottom of the fireplace in a proper workman like manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed. Ensure that existing chimney cleanouts fit properly. The refractory, glass doors, screen rails, screen mesh and log grates may be removed from the fireplace before installing the gas fireplace insert. Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners. The ventilation openings in the fireplace may be obstructed by the backer plates, aluminium trim etc. but these parts are not to be applied so as to have an airtight seal. Line the chimney with a 3" or 4" diameter approved liner. With a 4" liner, an increaser must be connected between the dilution draft hood and the liner. Chimney installation must conform to both national and local code requirements. The liner must be continuous from the fireplace to the chimney cap. FIGURE 2 Remove the securing screw from the front of the dilution plate. Push the dilution draft hood out of the securing clips and attach the liner using 3 screws equally spaced. Pack insulation around the liner at the damper area to prevent air flow from entering the chimney. Move the insert into the centre of the woodburning fireplace making sure that the dilution draft hood inserts back into its securing clips. Level using the four leveling screws located front and back on either side of the fireplace base. Leveling the insert will eliminate rocking or excessive noise when the fan is in operation. Replace the securing screw to the front of the dilution plate. FIGURE 3 Install rigid black pipe, a flex connector, if local codes permit, or 1/2" type L, copper tubing with a 3/8" to 1/2" adapter and a shut off valve to the fireplace. Seal and tighten securely. The adapter will be required between the gas valve and the copper tubing or flex connector. Do not kink flexible connector! Check for gas leaks by brushing on a soap and water solution. Do not use open flame! W415-0061 / B / 01.11.05 An on/off switch has been included and can be located at The insert can be equipped with a flashing kit to close off the right side trim. For ease of accessibility, this switch most fireplace openings. Mount the flashing inside the unit's may be replaced with a wall switch or substituted with a outer shell using 4 securing screws. The flashing and trim millivolt thermostat that may be installed in a convenient are available in many finishes to accent any room decor. location on any wall. Route a 2 strand solid core millivolt Objects placed in front of the fireplace should be kept a wire through the electrical hole located at the bottom right minimum of 48" away from the front face. side of the unit. The recommended maximum lead length depends on wire size: WIRE SIZE MAX. LENGTH 14gauge 100 feet 16gauge 60 feet 18gauge 40 feet Attach the two leads to terminals 1 and 3 located on the gas valve. FIGURE 4 1 2 3 FIGURE 5 Do not connect the gas valve to electricity (110 volts or 24 volts). W415-0061 / B / 01.11.05 UPPER LOUVRES Insert the back edge of the upper louvre into the upper louvre clips. FLUSH LOUVRE KIT, GI-1L FIGURE 8 UPPER LOUVRE LOUVRE CLIP SIDE VIEW L...

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien