Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Napoleon Fireplaces, modell BGD48P

Hersteller: Napoleon Fireplaces
Dateigröße: 2.41 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Tighten to ensure that a weather-tight seal between the air terminal connector and the collar is achieved. 9. Continue adding rigid venting sections, sealing and securing as above. Attach a 5" collapsed telescopic pipe to the last section of rigid piping. Secure with screws and seal. Repeat using a 8" telescopic pipe. 10. Run a bead of high temperature sealant around the outside of the 5" collar on the fireplace. Pull the adjustable pipe a minimum of 2" onto the collar. Secure with 3 screws. Repeat with the 8" telescopic pipe. 11. In the attic, slide the vent pipe collar down to cover up the open end of the shield and tighten. This will prevent any materials, such as insulation, from filling up the 1" air space around the pipe. RESTRICTING VERTICAL VENTS RESTRICTOR PLATE TOP OF THE FIREBOX FLUE COLLAR FIGURE 32 Vertical terminations display a very active flame. The vent exit must be restricted using restrictor plate, W500-0205. Remove the two screws on either side of the exhaust collar inside the firebox. Install the plate as shown. Replace the screws. GAS INSTALLATION GAS INSTALLATION Proceed once the vent installation is complete. NOTE: All gas connections must be contained within the fi replace when complete. 1. Move the fireplace into position and secure to the floor through the 1/4" holes located at either side of the base. 2. The fireplace is designed to accept 3/8" gas supply line. The fireplace is equipped with a 3/8" manual shut-off valve. 3. Connect the gas supply in accordance to local codes. In the absence thereof, install according to the National Installation Code. 4. When flexing any gas line, support the gas valve so that the lines are not bent or kinked. 5. Check for gas leaks by brushing on a soap and water solution. DO NOT USE OPEN FLAME. Purge all gas lines with the glass door of the stove removed. Assure that a continuous gas flow is at the burner before reinstalling the door. OPTIONAL WALL SWITCH INSTALLATION For ease of accessibility, an optional remote wall switch may be installed in a convenient location. Route 2-strand (solid core) millivolt wire through the electrical hole located at the bottom left side of the unit. The recommended maximum lead length depends on wire size: WIRE SIZE MAX. LENGTH 14 gauge 100 feet 16 gauge 60 feet 18 gauge 40 feet Attach the two leads to terminals 1 and 3 located on the gas valve. FIGURE 33 MOBILE HOME INSTALLATION This appliance is certified to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the mobile home appliance. This appliance is certified to be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes. This fireplace is only for use with the type of gas indicated on the rating plate. This fireplace is not convertible for use with other gases, unless a certified kit is used. Conversion Kits The mobile home appliance is field convertible between Natural Gas (NG) and Propane (LP). To convert from one gas to another consult your Napoleon dealer/ distributor. FRAMING Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity. It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes. It is not necessary to install a hearth extension with this fireplace system. When roughing in the fireplace, raise the fireplace to accommodate for the thickness of the finished floor materials, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower access door and the installation of many decorative flash ing accessories. Objects placed in front of the fireplace should be kept a minimum of 48" away from the front face. Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face areas of the fireplace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas. FIGURE 34 51 1/2" 481/2" 7211/16" This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fi replace is equipped with two 1/4” diameter holes located in the front left and right corners of the base. For mobile home installations, the fireplace must be fastened in place. Use #10 hex head screws...

Dieses Handbuch ist für folgende Modelle:
Kamine - BGD48N (2.41 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien