Anleitung Lennox Hearth, modell Millivolt LMDV-40 Series

Hersteller: Lennox Hearth
Dateigröße: 4.36 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


** In accordance with the curent ANSI SZ223.1/NFPA 54 National Fuel Gas Codes. *** Clearance required to vinyl soffit material -30 inches (76cm) minimum. ‡ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. *‡ Only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: Figure 7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 6 MINIMUM CLEARANCES TO COMBUSTIBLES Hearth Extension A hearth extension is not required with this appliance. If a hearth extension isused, do not block the lower control compartment door. Any hearth extension used is for appearanceonly and does not have to conform to standard hearth extension installation requirements. Wall Finishes / Surrounds / Mantels Note: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the appliance front face (black sheet metal). Never allow combustible materials to be positioned in front of or overlapping the appliance front face. See Figure 61 on Page 30. Non-combustible materials, such as surrounds and other appliance trim, may be installed on theappliance front face with these exceptions: they must not cover any portion of the removable glasspanel or louvers. Vertical installation clearances to combustible mantels vary according to the depth of the mantel. See Figure 8. Mantels constructed of non-combustible materials may be installed at any heightabove the appliance opening; however, do not allow anything to hang below the hood. 4 (102) 2 (51) 4 (102) 6 (152) 8 (203) 10 (254) 12 (305) 6 (152) 10 (254) 14 (356) 12 (305) 8 (203) Top of Appliance inches (millimeters)Mantel Depth Note -Hood shown as positioned with louvered panels. Figure 8 -Minimum Mantel Clearances Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded areas illustrated here. 5 (127) 8-1/4 (209) 14 (356) 12 (305) 19 (483) Combustible Materials Allowed In Shaded Area “Safe Zone” Combustible Walls shown in dark gray Minimum Distance to Unprotected Side Wall Top View of Fireplace 45o At 14" minimum side wall clearance, a combustible wall can project to any length. Protected wall shown in white Inches (millimeters) Figure 10 At 8-1/4" side wall clearance, a combustible wall can project 12" Shelf Above Fireplace With Rear Venting Do not insulate the space between theappliance and the area above it. Shelf Height (see table) *Shelf Height (see table) Do not insulate the space between the appliance and thearea above it. Shelf Above Fireplace With Top Venting Figure 9 -Shelf Height Minimum Clearances Model No. Combustible Shelf Height - Inches (millimeters) Top Vent -with One 90 Degree Elbow Rear Vent -Straight Out the Back Secure Vent Secure Flex (flex elbow) Secure Vent Secure Flex LMDVT-3328 *44-1/2 (1130) *46-1/4 (1175) N/A N/A LMDVR-3328 N/A N/A 33-1/4 (845) 33-1/4 (845) LMDV-3530 *46-1/2 (1181) *48-1/4 (1226) 35-1/4 (895) 35-1/4 (895) LMDV-4035 *51-1/2 (1308) *53-1/4 (1349) 40-1/4 (1022) 40-1/4 (1022) * Includes 3” clearance to combustibles (required above vent components) When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit. Appliance and Vent Clearances The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 8), with the following exception: When the unit is installed with onesideflush with a wall,the wall on the other side of the unit must not extend beyondthefrontedgeoftheunit.Inaddition,when the unit is recessed, the side walls surrounding the unit must not extend beyond the front edge of the unit. See Figure 4. MINIMUM CLEARANCES Inches (millimeters) Back 1/2 (13) 0 (0) Spacers Sides 1/2 (13) 0 (0) Spacers Top Spacers 0 (0) Floor 0 (0) Bottom of Appliance To Ceiling 64 (1626) Vent 3 (76) Top * 1 (25.4) Sides & Bottom SERVICE CLEARANCES Feet (meters) Front 3 ft. (0.9 m) Table 8 *Note: 3 in. (75 mm) above any horizontal/inclined vent component. **Note: See Page 8, Step 1 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. DETAILED INSTALLATION STEPS Theapplianceisshippedwithallgascontrolsand components installed and pre-wired. Remove the shipping carton, exposing the front glass door. Remove the top and bottom louvered control panel per instructions on Page 25 (see Control Compartment Access / Louver Panel Instructions). Remove the cardboard from underneath the pressure relief plates (in area behindtoplouverpanel,See Figure11). Open the two latches (located under the firebox floor) securing the glass door. Remove the door by tilting it outward at the bottom and lifting it up. Setthedoor aside protectingitfrom inadvertent damage. See Figure 57 on Page 29. REMOVE CARDBOA...

Dieses Handbuch ist für folgende Modelle:
Kamine - Millivolt LMDV-3530-CNE (4.36 mb)
Kamine - Millivolt LMDVT-3328-CNM (4.36 mb)
Kamine - Millivolt LMDV-4035-CNE (4.36 mb)
Kamine - Millivolt LMDVR-3328-CNE (4.36 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien