Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Lennox Hearth, modell ELITE E42ODGNE-H

Hersteller: Lennox Hearth
Dateigröße: 1.65 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Once purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lighting of the appliance will not require such purging. Inspect the pilot flame (remove logs, if necessary, handling carefully). After the logs have been placed and the fireplace has been checked for proper flame presentation, use the remaining rock to fill in voids and spaces. Remember, you may need to access the high/low flame control beneath the refractory cover. Electronic Appliance Checkout To light the burner, turn ‘ON’ the remote wall switch. The battery will energize a spark that will light the pilot. The pilot flame will engulf the sensor and open the main valve. Within seconds the main burner will light. Ensure the ignitor lights the pilot. The pilot flame should engulf the sensor as shown in Figure 17. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly. Firebox Finishes There are a wide variety of "finished looks" for your outdoor fireplace, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like marble, stone, tile, brick, etc. may overlap the top and sides of the front facing. Seal all joints between the black facing and wall surrounds to prevent air intrusion. Use noncombustible caulking materials only to seal the metal facing to the surround material on the finished wall. See Figure 18. Caution: Do Not block the face opening on these fireboxes. Doing so may create a potential fire hazard. 6" MinimumFor CombustibleMaterials 2" Max. 3-3/4" Max. See Note29" Min. WallSwitch5" Min. Note: the Area Above the Faceto the top Of the SpacersMust Be Non-Combustable Materials ELECtrONICPilotHoodSensorIgnitor Figure 17 Figure 18 Clearances To Combustibles Installation Accessories And Components drain PanCat. No.ModeldescriptionH465 dPSS36drain Pan (36) H4652dPSS42drain PanThe drain pan is used with the appliance. drain Pan (42) Gas Conversion Kits Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions and all applicable codes and requirements of the authorized having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the owner instructions supplied with the kit. THE QUALIFIED SERVICE AGENCY PERFORMING THIS INSTALLATION ASSUMES RESPONSIBILITY FOR THIS CONVERSION. Avertissement: Cet Equipement de conversion sera installE par une agence qualifiEe de service conformEment aux instructions du fabricant et toutes exigences et codes applicables de l'autorisEs avoir la juridiction. Si l'information dans cette Instruction n'est pas suivie exactement, un feu, explosion ou production de protoxyde de carbone peut rEsulter le dommages causer de propriEtE, perte ou blessure personnelle de vie. L'agence qualifiEe de service est esponsable de l'installation propre de cet Equipment. L'installation n'est pas propre et complEte jusqu'a l'opEration de l'appareil converti est chEque suivant les criteres Etablis dans les instructions de propriEtaire provisionnEes avec l'Equipement. Step 1. Turn off the gas supply to the appliance. Step 2. Carefully remove the logs. Exercise care so as not to break the logs. Step 3. Refer to Figure 19. Remove the burner assembly with attached venturi tube. In Canada: The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CAN1-B149.1 and .2 installation code. LA CONVERSION DEVRA ETRE EFFECTUEE CONFORMEMENT AUX RECOMMANDATIONS DES AUTORITES PROVINCIALES AYANT JURIDICTION ET CONFORMEMENT AUX EXIGENCES DU CODE D'INSTALLATION CAN1-B149.1 ET.2. Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the necessary components needed to complete the task including labeling that must be affixed to ensure safe operation. Kit part numbers are listed here and the ...

Dieses Handbuch ist für folgende Modelle:
Kamine - ELITE E36ODGNE (1.65 mb)
Kamine - ELITE E36ODGNE-H (1.65 mb)
Kamine - ELITE E36ODGPE (1.65 mb)
Kamine - ELITE E36ODGPE-H (1.65 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien