Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Excalibur electronic, modell P95-LP3

Hersteller: Excalibur electronic
Dateigröße: 5.06 mb
Dateiname:
Unterrichtssprache:
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. INSTALLATION CHECKLIST 1) Check all clearances to combustibles. Refer to the following sections: a) Locating Your Gas Fireplace b) Clearances c) Combustible Mantels d) Unit Base Stand-offs e) Framing and Finishing f) Hearth Requirement g) Unit Assembly Prior to Installation h) Venting 2) Make gas and electrical connections. Test the pilot. Must be as per diagram. Refer to the "Gas Line Installation" section. 3) Install standard and optional features. Refer to the following sections where applicable: a. Brick Panels b. Log Set c. Glass Door d. Arch Surround e. Double Screen Doors f. Accent Kit (Double Door & Surround) g. Remote Control h. Wall Switch i. Wall Thermostat 4) Final check. Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to customer. This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label 45,000 Btu/h) after burning appliance for 15 minutes. 2) If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize. CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer. Excalibur® P95-3 Zero Clearance Direct Vent Gas Fireplace INSTALLATION LOCATING YOUR GAS FIREPLACE 1) When selecting a location for your fireplace, ensure that the clearances outlined on this page are met. 2) Provide adequate clearances for servicing. 3) The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete). This may be the floor, or raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or other combustible material other than wood flooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance. 4) The P95-3 Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C, D. See Diagram 1. Diagram 1 A) B) C) D) Flat on Wall Flat on Wall Corner Recessed into Wall/Alcove Corner 5) This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation. 6) The P95-3 Direct Vent Gas Fireplace is approved for alcove installations, which meet the clearances listed on this page. 7) We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualified inspector, dealer, or installer review your plans before installation. Note: For vent terminations see the "Venting" section. MANUFACTURED M...

Dieses Handbuch ist für folgende Modelle:
Kamine - P95-LP3 (5.06 mb)
Kamine - P95-NG3 (5.06 mb)
Kamine - P95-NG3 (5.06 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien