Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Desa, modell (V)K42N SERIES

Hersteller: Desa
Dateigröße: 2.6 mb
Dateiname: 3e4eee6b-8280-de54-5103-d37351c79c81.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


2. Cap off open end of gas pipe where equipment shutoff valve was connected. 3. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. 4. Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fittings for leaks. For more information, visit more information, visit 111921-01B 111921-01B Forr morre iinfforrmattiion,, viisiitt 20 FIREPLACE INSTALLATION Continued FIREPLACE INSTALLATION Checking Gas Connections (Cont.) Installing Optional Wall Mount Switch - GWMS2 Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Figure 33). 2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace, or using compressed air. 3. Check all joints from propane/LP supply tank or gas meter to equipment shutoff valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. Figure 33 - Equipment Shutoff Valve Open Closed Equipment Shutoff Valve Figure 35 - Checking Gas Joints for Natural Gas Fireplace Figure 34 - Checking Gas Joints for Propane/LP Gas Fireplace Propane/LP Supply Tank Gas Valve Equipment Shutoff Valve Gas Meter Gas Valve Equipment Shutoff Valve Pressure Testing Fireplace Gas Connections 1. Open equipment shutoff valve (see Figure 33). 2. Open propane/LP supply tank valve for propane/LP fireplace or main gas valve located on or near gas meter for natural gas fireplace. 3. Make sure control knob of fireplace is in the OFF position. 4. Check all joints from equipment shutoff valve to gas valve (see Figure 34 for propane/LP or Figure 35 for natural gas). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once. 5. Light fireplace (see Operating Fireplace, pages 24 through 26). Check all other internal joints for leaks. 6. Turn off fireplace (see To Turn Off Gas to Appliance, page 24). Figure 36 - Connecting Wall Swith to Control Valve INSTALLING OPTIONAL WALL MOUNT SWITCH - GWMS2 1. Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 36. If wires are not connected as shown the switch will not work. 2. Route the 25 ft. wire through openings provided on the sides of the burner system to a convenient location to mount your switch. 3. Connect one bare wire end to each of the terminals of the GWMS2 wall switch. 4. Install the wall switch and cover in the wall. To Wall Switch Accessory FIREPLACE INSTALLATION Installing Optional Wireless Hand-Held Remote Control - GHRCB and GHRCTB Series Removing/Replacing Glass Door 21 FIREPLACE INSTALLATION Continued INSTALLING OPTIONAL WIRELESS HANDHELD REMOTE CONTROL - GHRCB AND GHRCTB SERIES NOTICE: Use only alkaline batteries (not included). Installing Remote Receiver 1. Open bottom louver and locate the switch bracket on the left. 2. Unscrew the switch bracket. Lean bracket forward so you are able to access the back of the remote receiver. 3. Locate the battery clip mounted on the back of the receiver. Slide a 9-volt alkaline battery (not included) through the clip (see Figure 37, page 21). 4. Attach the terminal wires to the battery. 5. Connect wires from receiver to TH and TPTH to control valve (see Figure 38). 6. Replace the switch bracket. Receiver 9-Volt Alkaline Battery Clip Terminal Battery Wires Figure 37 -Attaching Alkaline Battery to Receiver To Optional Remote Accessory Figure 38 - Control Valve Terminals Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit 1. Remove battery cover on back of remote control unit. 2. Attach terminal wires to a 9-volt alkaline battery (not included). Place battery into the battery housing. 3. Replace battery cover onto remote control unit. Wires 9-Volt Alkaline Battery Battery Cover Terminal Remote Control Unit Battery Housing Terminal 9-Volt Battery Remote Control Unit Battery Cover Wires Figure 40- Installing Battery in Hand-Held Remote Control Unit (GHRCTBSeries) REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For replacement part information see Replacement Parts, page 31. Removing Louver Panels Remove the top and bottom louver panels by simultaneously pulling both top end spring latches towards the center ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien