|
Anleitung Zusammenfassung
You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery. Blower Control Knob (Optional Accessory) Variable Control Knob Selector Switch in Remote Position Gas Control Knob in ON Position Figure 46 - Setting the Selector Switch, Gas Control Knob and Variable Control Knob for Remote Operation 116239-01B OPERATING FIREPLACE Optional Hand-Held Remote Operation (Cont.) 25 OPERATING FIREPLACE Continued ON/OFF SERIES MODEL GHRCB Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 47). TO LOCK press both buttons on hand-held remote control until light stops flashing. Hand-held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed. TO UNLOCK press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked. Control Button Turns Burners On and Off Figure 47 - On/Off Hand-Held Remote Control Unit GHRCB THERMOSTAT SERIES MODEL GHRCTB The hand-held remote can be operated using either the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 48). To select Fahrenheit/Centigrade mode display, carefully press the .C/.F mode button with the end of a paper clip or similarblunt object. Manual Mode 1. Press the POWER and LOCK buttons together to turn on the hand-held remote control. 2. Press the MANU button to turn on the fireplace. 3. Press the POWER and LOCK buttons together to turn off the fireplace. Auto (Thermostatic) Mode 1. Press the POWER and LOCK buttons together to turn on the hand-held remote control. 2. Press AUTO button to select this mode. 3. Set the desired room temperature by pressing the TEMP+ or -buttons. 4. Press the POWER and LOCK buttons together to turn off the fireplace Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace. Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode. Safety Features When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position. Auto Shutoff Feature 1. If the average room temperature exceeds 82 degrees Fahrenheit (28 degrees Centigrade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode. 2. The receiver continuously receives signals from the handheld remote to control the room temperature. If the handheld remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes. Key Pad Lock Feature Thisfeatureallowstheusertolock/unlockthekeypadonthehandheld remote in the MANU or AUTO mode to prevent inadvertentoperation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWERand LOCK buttons together to turn the unit on or off. Turns Hand-Held Shows Digital Display Remote On or Off and Temperature and Allows You to Choose Settings the Manual Setting Selects Auto Setting On or Off Increases Room Decreases Room Turns Burners Temperature in AUTO Temperature in Mode AUTO Mode Locks System to Prevent Accidental Ignition Figure 48 -Thermostat Hand-Held Remote Control Unit GHRCTB 116239-01B 26 OPERATING FIREPLACE Operating Optional GWMT1 Wall Mounted Thermostat Operating Optional Blower Accessory INSPECTING BURNERS Pilot Assembly Burner Flame Pattern OPERATING FIREPLACE Continued OPERATING OPTIONAL GWMT1 WALL MOUNTED THERMOSTAT WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur. Light the fireplace as instructed in Lighting Instructions on page 23. Set wall thermostat to desired temperature. Thisthermostathasbeenelectronically calibrated atthefactory and requires no adjustment or leveling. Upon installation, the thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. To turn the fireplace off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit. IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position. OPERATING OPTIONAL BLOWER ACCESSORY Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the right side of the switch bracket to the left just inside the louver panel. TheBKmanualblowerandtheBKTthermostatically-contro...
Dieses Handbuch ist für folgende Modelle:Kamine - (V)KC42P SERIES (2.05 mb)