Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Superior, modell DIRECT-VENT GAS FIREPLACES SDV35

Hersteller: Superior
Dateigröße: 2.37 mb
Dateiname: Lennox_Hearth_SDV_Care_Operation_725039M.pdf
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


(see Figures 3 and 4 on Page 9). These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa). Orifice Sizes -Sea Level to High Altitude (All Models) These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard burner orifice sizes (marked with an "*" in Table 4). For elevations above 4500 feet, contact your gas supplier or qualified service technician. Deration -At higher elevations, the amount of BTU fuel value delivered must be reduced by either: • Using gas that has been derated by the gas company. • Changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54/ANSI Z223.1 -latest edition or, in Canada, the CAN/CSA-B149.1 codes - latest edition. Installtheapplianceaccordingtotheregulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada, the CAN/CSA-B149.1 - latest edition. NOTE: Flame appearance will diminish 4% per thousand feet. Burner Orifice Sizes Elevation 0-4500 feet ( 0-1372 meters) Model Series Natural Gas drill size (inches) Propane Gas drill size (inches) SDV35 2.3 mm (.090") * 37L70 • #54 (.055") * 99K79 • * Standard size installed at factory • Part /Cat. Number Table 4 Burn-in Period During the first few fires of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. Depending on your use, the burn-in period may take a few hours or a few days. KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR. Do not turn on the air circulation blower during the Burn-In period. A white film may develop on the glass front during the first few fires as part of the curing process. The glass should be kept clean during thefirsttwoweeksofusetopreventthefilmfrom baking on (making it very difficult to remove). See Cleaning Glass on Page 10. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. OPERATION AND CARE OF YOUR APPLIANCE WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces. AVERTISSEMENT Les jeunes enfants devraient etre surveilles etroitement lorsqu’ils se trouventdanslamemepiecequel’appareil.Lestoutpetits,lesjeunesenfants ou les adultes peuvent subir des brulures s’ils viennent en contact avec la surface chaude. Il est recommande d’installer une barriere physiquesi des personnes a risques habitent la maison. Pour empecher l’acces a un foyer ou a un poele, installez une barriere de securite; cette mesureempechera les tout petits, les jeunes enfants et toute autre personne arisque d’avoir acces a la piece et aux surfaces chaudes. Figure 1 Sit and Honeywell Millivolt Gas Valve Showing Piezo Igniter Location (Each Unit is Equipped with Only One of these Gas Valves) Figure 2 OPENING CONTROL COMPARTMENT DOOR Control Valve Lower Control Compartment Door SIT Gas Valve Shown with control compartment door removed Piezo Igniter HoneywellGas Valve Lift the Lower Control Compartment Doorup and pull out to remove. Up Out Hook Catch Gas Controls/Control Compartment Access Thegascontrolscanbefoundbehindthecontrol compartment access door. Removing Control Compartment Door: Open the door by gently lifting it upward until thehookcatchesonbothsidesclearthelocating slots. Then pull door out to remove. On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas ON/OFFcontrolknobarelocatedbelowtheglass panel enclosure. See Figures 1 and 2. Reinstalling Control Compartment Door: To reinstall, insert the hook catches on each side of the door into the corresponding slots in the control compartment opening, then gently push forward and slide down until it locks in place. The standard controls for appliance operation are located in the control compartment located below the appliance front glass enclosure panel (see Figures 1 and 2). Optional burner control switches are also available (see Page 17 -remote control, Unit Mounted Rocker Switch, wall thermostat or wall switch). Before lighting and ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien