Anleitung Lopi, modell Revere
Hersteller: Lopi Dateigröße: 1.04 mb Dateiname: 222a618d-2b59-4716-8a7b-22f0bb38fe52.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
16. If for any reason any section of this warranty is declared invalid, the balance of the warranty remains in effect and all other clauses shall remain in effect. 17. This 7 year warranty is the only warranty supplied by Travis Industries, Inc., the manufacturer of the appliance. All other warranties, whether express or implied, are hereby expressly disclaimed and purchaser’s recourse is expressly limited to the warranties set forth herein. IF WARRANTY SERVICE IS NEEDED: 1. If you discover a problem that you believe is covered by this warranty, you MUST REPORT it to your Travis dealer WITHIN 30 DAYS, giving them proof of purchase, the purchase date, and the model name and serial number. 2. Travis Industries has the option of either repairing or replacing the defective component. 3. If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC., including the name of the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your appliance. At that time, you may be asked to ship your appliance, freight charges prepaid, to TRAVIS INDUSTRIES, INC. TRAVIS INDUSTRIES, INC., at its option, will repair or replace, free of charge, your appliance if it is found to be defective in material or workmanship within the time frame stated within this 7 year warranty. TRAVIS INDUSTRIES, INC. will return your appliance, freight charges (years 1 to 5) prepaid by TRAVIS INDUSTRIES, INC., to your regional distributor, or dealership. 4. Check with your dealer in advance for any costs to you when arranging a warranty call. Mileage or service charges are not covered by this warranty. This charge can vary from store to store. © Travis Industries 100-01165 4040806 28 Listing Label 28 Listing Label Listing Label CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA SERIAL NO: MODEL: Report No. 028-S-44-4 LOPI® REVERE (X-NT) Listed Fireplace Insert for installation into a Factory-Built (Z.C.) fireplace or masonry fireplace WARNING - DO NOT REMOVE THIS LABEL A representative product sample of this model stove has been tested to meet UL 1482 Standards for safety. For use with solid wood fuels only. Install and use only in accordance with the manufacturers installation and operation instructions. Check all local building codes. DO NOT ELEVATE FIRE. Build fires directly on the firebrick. Install with or without a direct flue connector pipe in a MASONRY FIREPLACE with facing shroud plates. Factory-Built (Z.C.) Fireplace installations require a minimum 24” starter section directly connected to the fireplace chimney or a full re-line. Factory-Built (Z.C.) Fireplace chimney must have a minimum cross-sectional area of 28.85”. The Factory-Built (Z.C.) Fireplace damper and control must be removed, or secured in the open position. For minimum Factory-Built (Z.C.) Fireplace firebox size, see manufacturer’s installation instructions. Factory-Built (Z.C.) Fireplace floor protection must be 3/8” minimum non-combustible material or equivalent, extending 16” in front of insert and 8” to both sides. A metal deflector plate must be installed if the flue collar is not completely behind the Lintel plate of the Factory-Built (Z.C.) Fireplace openings. Inspect and clean chimney frequently. Under certain conditions of use, creosote buildup may occur rapidly. DO NOT OVERFIRE. If heater glows, you are overfiring. Do not remove bricks or mortar from masonry fireplace. OPEN DAMPER BEFORE OPENING LOADING DOORS! Maintain 36" front clearance to all furnishings and other combustible materials. CLEARANCE TO COMBUSTIBLES, MASONRY FIREPLACE INSTALLATION INSERT CLEARANCE DIAGRAM Note: Replace glass only with 5mm Lopi ceramic OPTIONAL 125 CFM BLOWER PACKAGE MANTEL HEARTH EXTENSION FACIA OR TRIM INSERT SIDEWALL A B CD 8 16 Minimum Clearance to Combustibles and Hearth Requirements Masonry Fireplace Installations Factory-Built (Z.C.) Fireplace Installations A. 15” 30” B. 13” 12” C. 28.5” 12” With Shield 20.5” N/A D. 30.5” 24” With Shield 22.5” N/A Hearth Extension Front 16” 16” Hearth Extension Sides 8” 8” Electrical Rating: Volts-115 Watts-21.4 Amps-1.8 HZ-60 10850 117th Pl. N.E. Kirkland, WA 98033 Manufactured By: U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with July 1990 particulate emission standards. Date of Manufacture 2001 2002 2003 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec. 0234 © Travis Industries 100-01165 4040806 Optional Equipment 29 Optional Equipment 29 Door Shell Installation Part Numbers: Black # 99300195, Brass # 9930096, Pewter # 99300197 1 Remove the door retainer shipping latch following the directions below. Standard Screwdriver Rotate this shaft 1/4 turn clockwise until the door unlatches. Swing the door retianer open. Remove and discard the shipping latch and nut. 9/16" Wrench Shipping Latch Door Retainer 2 Place the door shell...