If in doubt about its condition, seek professional advice. Your Regency Insert is designed for installation into a masonry fireplace that is constructed in accordance with the requirements of "The Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Appliance", N.F.P.A. 211, the National Building Code of Canada, or the applicable local code requirements. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1. Regency Inserts are designed with a 6" flue. Requirements for Installing Solid-fuel Inserts in Factory-built Fireplaces. 1) The insert must be tested and meet the requirements of UL 1482 (U.S.) and or ULC S628 (Canada) when tested in a masonry fireplace built per ULC S628. 2) The factory-built fireplace must be listed per UL 127 or ULC S610. 3) Clearances obtained from the masonry fireplace tests are also relevant for installation in factory-built fireplaces. 4) Installation must include a full height listed chimney liner type HT requirements (2100 degree F.) per UL 1777 (U.S.) or ULC S635 (Canada). The liner must be securely attached to the insert flue collar and the chimney top. 5) Means must be provided to prevent room air passage to the chimney cavity of the fireplace. This may be accomplished by sealing the damper area around the chimney liner, or sealing the fireplace front. 6) The air flow within and around the fireplace shall not be altered by the installation of the insert (i.e. no louvers or cooling air or outlet ports are blocked), unless specifically tested as such for each factory-built fireplace manufacturer and model line. (Note - using a louvered face plate (surround) complies with this requirement). 7) Alteration of the fireplace in any manner is not permitted with the following exceptions; a. external trim pieces which do not affect the operation of the fireplace may be removed providing they can be stored on or within the fireplace for re-assembly if the insert is removed. b. the chimney damper may be removed to install the chimney liner. 8) Circulating air chambers (i.e. in a steel fireplace liner or metal heat circulator) shall not be blocked. 9) Means must be provided for removal of the insert to clean the chimney flue. 10) Inserts that project in front of the fireplace must be supplied with appropriate supporting means. 11) A permanent metal warning label must be attached to the back of the fireplace stating that the fireplace must be restored to its original condition for safe use with out the insert. In order for a solid-fuel insert to be certified for use in factory-built fireplaces, the above information must be clearly stated in the installation manual and appropriate markings. Final approval is contingent on the authority having jurisdiction. FIREPLACE SPECIFICATIONS Your fireplace opening requires the following minimum sizes: Height Width Depth Small (I1100S) 20" 23" 13.25" Medium (I2100M) 21.5" 25" 17" Large (I3100L) 25" 28" 17" Hearth Heater (H2100M) 20.0" --- Two faceplates are available to seal the fireplace opening: Standard Oversize Small (I1100S) 36"W x 26"H 39.875"W x 30"H Medium (I2100M) 40"W x 30"H 48"W x 33"H Large (I3100L) 44"W x 32"H 50"W x 34.5"H Hearth Heater (H2100M) 40 1/4"W x 30"H 48"W x 33"H INSTALLING YOUR INSERT Your insert is very heavy and will require two or three people to move it into position. The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges. Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation. Convection Grills for I2100M & I3100L The convection grills are installed before the unit is positioned inside the fireplace. Regency Insert & Hearth Heater INSTALLATION Position the grill on the inside bodyface side and fasten using the bolts, washers and nuts provided (2 per side) as shown in the diagrams. Note: The grill has a front and rear, the holes on the front side have rounded edges and the rear holes have flat edges. OPTIONAL FLUE CONNECTOR KIT The optional Flue Connector Kit (Part # 846-527) and the Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your flue connector and the insert collar. Detailed installation instructions are included with the kit. View from Rear of Insert MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below. Unit Adjacent Side Wall (to Side) A Mantle** (to Top) B Top Facing (to Top) C Side Facing (to Side) D Minimum Hearth Extension* E Minimum Hearth Thickness* F MinimumHearth Side Extension G Small Flush Insert (I1100S) 15"/380mm 20"/510mm 14"/355mm 7.375"/187mm 16"/406mm 1.5"/38mm 8"/205mm Medium Flush Insert (I2100M) 10"/255mm 17"/430mm 10.25"/260mm 8"/203mm 16"/...