Login:
Stimmen - 3, Durchschnittliche Bewertung: 5 ( )

Anleitung Regency, modell G36D

Hersteller: Regency
Dateigröße: 19.7 mb
Dateiname: 14748427-fd6a-49e7-a12b-7ef314b9c2ad.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


1) Make sure the valve is in the "OFF" position. 2) Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide flat screwdriver. 3) Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose. G36D-NG1 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #42 Max. Input Rating 26,000 Btu/h Min. Input Rating 13,100 Btu/h Supply Pressure min.5.0" w.c. Manifold Pressure (High) 3.8"+/- 0.2"w.c. Log Set: Ceramic fibre, 7 per set. Vent System: Simpson Dura-Vent Direct Vent System or UltraGlow® Direct®® Vent System (Flex) G36D-LP1 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #53 Max. Input Rating 26,000 Btu/h Min. Input Rating 13,800 Btu/h Supply Pressure min.12.0" w.c. Manifold Pressure (High) 11"+/- 0.2" w.c. Log Set: Ceramic fibre, 7 per set. Vent System: Simpson Dura-Vent Direct Vent System or UltraGlow® Direct Vent System (Flex) HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft. (CAN1 2.17-M91) with the orifice supplied. GAS LINE INSTALLATION The gas line can be brought through either the right or the left side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve. Note: If the gas line is being installed from the left side, be sure to leave room to accommodate servicing of the fan. The gas line connection may be made of rigid pipe,copperpipeoranapprovedflexconnector. (If you are using rigid pipe, ensure that the valve can be removed for servicing.) Since some municipalities have additional local codes it is PILOT ADJUSTMENT Periodically check the pilot flames. Correct flame pattern has three strong blue flames: 1 flowing around the thermopile, 1 around the thermocouple and 1 flowing across the burner (it does not have to be touching the burner). Note: Ifyouhaveanincorrectflamepattern, contact your Regency® dealer for further instructions. Incorrect flame pattern will have small, probably yellow flames, not coming into proper contact with the rear burner or thermopile or thermocouple. GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig. 4) Light the pilot and turn the valve to "ON" position. 5) The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label. 6) When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten. snug, but do not over tighten.snug, but do not over tighten. S.I.T. VALVE DESCRIPTION 1) Gas on/off knob 2) Manual high/low adjustment 3) Pilot Adjustment 4) Thermocouple Connection -option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) AlternativeAlternative TC ConnectionAlternative TC Connection Point UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace 23 INSTALLATION CONVERSION KIT #773-969 FROM NG TO LPG FOR G36D-1 USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Each Kit contains one LPG Conversion Kit and one DC Sparker Kit. LPG Conversion Kit Contains: Qty. Part # Description 1 904-345 Burner Orifice #53 1 908-528 Red "LPG" label 1 908-255 Label "Converted to LPG" 1 908-529 5/32" Allen Key 1 910-037 LP Injector (Pilot Orifice) 1 918-476 Instruction Sheet DC Sparker Kit Contains: Qty. Part # Description 1 820-475 Bracket DC Sparker 1 820-476 Bracket DC Sparker 1 904-153 Washer #8 External Star 1 904-330 Nut 8-32 Hex 1 904-438 Plug Nylon 0.750 Hole, Black 2 904-531 Bushing Split Plastic 0.500 in. 1 904-543 Screw 8-32 x 3/4 Pan Head 2 904-553 Screw #8 x 1/2 Type "B", Black Oxide 1 910-073 Spark Generator Battery Holder 1 910-074 Spark Generator Switch C/W Wire 1 910-078 Battery Size AA Energizer En91 1 910-199 Clip Wire Holder 1 910-903 Wire Fan To Power Cord Ground 30 in. 1 910-480 Instruction Sheet 904-781 Velcro Hook, Black 904-782 Velcro Hook, Black Installation of LPG Conversion Kit: 1) Shut of Shut ofShut ofShut off the gas supply. 2) Remove the louvers (and bay door if it is installed). 3) Open the flush door and remove the door. 4) Remove the logs and embers. 5) Remove the 2 screws holding the Burner Assembly to the firebox base. Push the Burner Assembly to the left and lift out. Remove the 2 screws, push Burner Assembly to the left and lift out. 6) Pull of Pull ofPull ofPull off the pilot cap to expose the pilot orifice. 7) Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap. 8) Remove burner orifice wi...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien