Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung Monessen Hearth, modell SDV35

Hersteller: Monessen Hearth
Dateigröße: 4.91 mb
Dateiname: Lennox_Hearth_SDV_Installation_700036M.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


For projections exceeding 2-1/2" (64 mm), see Figure 5. For additional vent location restrictions refer to Figure 6 on Page 7. Note -See Figure 36 on Page 20 for the exterior wall recess allowances of the square horizontal termination. Figure 5 6" (152 mm)12" (305 mm) Combustible Projection greater Horizontal Vent Termination Clearances Combustible Projection2-1/2 inches or less in length 18" (457 mm) Ventilated Soffit Unventilated Soffit than 2-1/2 inches in length Termination Kit Side Elevation View Termination Kit All horizontal terminations may be located as close as 6” (152mm) to any (non-combustible and combustible) exterior sidewall. This distance may be decreased to 2” (51mm) for non-- combustible exterior sidewalls only, if the SV4.5HT-2 termination is used. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS V VFCFixed Closed Window Operable Window B B A B H M I = Area where Termination is not Permitted= Air Supply Inlet X = Vent Termination V D V 3 ft. 3 ft. A A A = 9” in U.S. = 12” in Canada L B J X V A G C Inside Corner Detail BC C *18” Ventilated Soffit Horizontal Termination Detail D Exterior Wall 6” Inside Corner * See Item D in the Text Below. P O N N Q NOTE: Local Codes Or Regulations May Require Different Clearances. NOTE: Location Of The Vent Termination Must Not Interfere With Access To The Electrical Service. E K X ...... EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS V VFCFixed Closed Window Operable Window B B A B H M I = Area where Termination is not Permitted= Air Supply Inlet X = Vent Termination V D V 3 ft. 3 ft. A A A = 9” in U.S. = 12” in Canada L B J X V A G C Inside Corner Detail BC C *18” Ventilated Soffit Horizontal Termination Detail D Exterior Wall 6” Inside Corner * See Item D in the Text Below. P O N N Q NOTE: Local Codes Or Regulations May Require Different Clearances. NOTE: Location Of The Vent Termination Must Not Interfere With Access To The Electrical Service. E K X ...... Canadian Installation* US Installation** A = Clearance above grade, veranda, porch, deck, or balcony. 12 inches (30cm)* 12 inches (30cm)** B = Clearance to window or door that may be opened. 6 in (15cm) for appliances < 10,000 Btuh (3kW), 12 in (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36 inches (91cm) for appliances > 100,000 Btuh (30kW)* 6 in (15cm) for appliances < 10,000 Btuh (3kW), 9 in (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12 inches (30cm) for appliances > 50,000 Btuh (15kW)** C = Clearance to permanently closed window 12" (305mm) recommended to prevent window condensation 9" (229mm) recommended to prevent window condensation D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 18 inches (458mm) from the center line of the terminal 18" (458mm) 18" (458mm) E = Clearance to unventilated soffit 12" (305mm) 12" (305mm) F = Clearance to outside corner 5" (12.7cm) minimum 5" (12.7cm) minimum G = Clearance to inside corner 2" (5.08cm) minimum - SV4.5HT-2 • 6" (15.2cm) minimum - SV4.5HTSS 2" (5.08cm) minimum - SV4.5HT-2 • 6" (15.2cm) minimum - SV4.5HTSS H = Clearance to each inside of center line extended above meter/regulator assembly 3 feet (91cm) within a height of 15 feet above the meter/regulator assembly* 3 feet (91cm) within a height of 15 feet above the meter/regulator assembly** I = Clearance to service regulator vent outlet 3 feet (91cm)* 3 feet (91cm)** J = Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance 6 in (15cm) for appliances < 10,000 Btuh (3kW), 12 in (30cm) for appliances > 10,000 Btuh (3kW) and < 100,000 Btuh (30kW), 36 inches (91cm) for appliances > 100,000 Btuh (30kW)* 6 in (15cm) for appliances < 10,000 Btuh (3kW), 9 in (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12 inches (30cm) for appliances > 50,000 Btuh (15kW)** K = Clearance to a mechanical air supply inlet 6 feet (1.83m)* 3 feet (91cm) above if within 10 feet (3m) horizontally** L = Clearance above paved sidewalk or paved diveway located on public property 7 feet (2.13m)‡ 7 feet (2.13m)‡ M = Clearance under veranda, porch, deck or balcony 12 inches (30cm)*‡ 12 inches (30cm)‡ * In accordance with the current CSA-B149.1 National Gas And Propane Installation Code. ** In accordance with the curent ANSI SZ223.1/NFPA 54 National Fuel Gas Codes. ‡ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. *‡ Only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: • 2" Clearance to Non-Combustibles for SV4.5HT-2 Only. Figure 6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. MINIMUM CLEARANCES TO COMBUSTIBLES Hearth Extension A hearth extension is not required with this appliance. If a hearth extension is used, do not block the lower c...

Dieses Handbuch ist für folgende Modelle:
Kamine - SDV35 (4.91 mb)
Kamine - SDV35 (4.91 mb)
Kamine - SDV35 (4.91 mb)
Kamine - SDV35 (4.91 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien