Anleitung Ativa, modell PET1030
Hersteller: Ativa Dateigröße: 319.81 kb Dateiname: 575-090_manual.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
(upper display) 14 [=] (The final result is automatically rounded to the specified three decimal places.) 400.000 Cancel specification by specifying "Norm" again. [MODE][MODE][MODE][3][1] 400. Before Starting Calculations If after making corrections, input of the formula is To clear memory contents, press [0] [STO] [M]. Addition/subtraction to or from sum in memory cannot be carried out with [M+], [SHIFT] [M–] keys in "SD" mode and "REG" mode. Difference between [STO][M] and [M+], [SHIFT][M–] : Both [STO] [M] and [M+], [SHIFT] [M–] can be used to input results into memory, however when the [STO] [M] operation is used, previous memory contents are cleared. When either [M+] or [SHIFT] [M–] is used, value is added or subtracted to or from present sum in memory. Example: Input 456 into memory "M" using [STO] [M] procedure. Memory already contains value of 123. Operation Modes complete, the answer can be obtained by pressing [ = ]. If, however, more is to be added to the formula, advance the When using this calculator, it is necessary to select the cursor using the [4] key to the end of the formula for proper mode to meet your requirements. This can be done input. by pressing [MODE] to scroll through sub-menus. Then select the appropriate mode by keying in the number. If an unnecessary character has been included in a formula, use the [3] and [4] keys to move to the position of the error and press the "DEL" key. Each press Press [MODE] once to read the first page of the main of "DEL" will delete one command ( one step ). menu. COMP SD REG 1 2 3 AT-30i Example: To correct an input of 369 . . 2 to 369 . 2 : 369xx2_ D 0. 369x2 D 0. 369[.][.]2 Press [MODE] again. [3][3][DEL] Deg Rad Gra1 2 3 M= M M M M 123. D M= 456. D _ 0. D M= 456. D [ON/AC] [1] [2] [3] [STO] [M] Rounding the Intermediate Result Press [MODE] further. Fix Sci Norm 1 2 3 As the number of decimal places is specified, the If a character has been omitted from a formula, use the [ON/AC] [4] [5] [6] [STO] [M] intermediate result will be automatically rounded to the [3] and [4] key to move to the position where the character should have been input, and press [SHIFT] 2-lines display specified decimal places. However, the stored Scientific Calculator intermediate result is not rounded. In order to match the Press "MODE" once more to leave the menu. followed by [INS] key. Each press of [SHIFT] [INS] will [ON/AC] _ 0. displayed value and the stored value, [SHIFT] [Rnd] can be input. Example: To correct an input of 2.362 to sin 2.362 : create a space for input of one command. [RCL] [M] 2[•]36[x2] You can compare the final result obtained in the previous Calculation Modes example with the final result of the following example. with advance "COMP" mode : - general calculations, including function calculations can be executed. statistical functions "SD" mode:- standard deviation calculation can be [3][3][3][3][3] executed. "SD" symbol appears in display. "REG" mode:- regression calculations can be performed. "REG" symbol appears in display. [SHIFT][INS] Example: Input 456 into memory "M" using M+. Memory already contains value of 123. Angular Measurement Modes "DEG" mode:- specify measurement in "degrees". "D" [sin] symbol appears in display window. "RAD" mode:- specify measurement in "radians". "R" 2.362 _ D 0. 2.362 D 0. .362 D 0. sin .362 D 0. symbol appears in display window. When [SHIFT] [INS] are pressed, the space that is opened Example Operation Display (Lower) 200.7.14 = 400 200[.]7 [.] 14[=] 400. rounded to 3 decimal places [MODE][MODE][MODE][1][3] 400.000 200[.]7 [=] The intermediate result is automatically rounded to the specified three decimal places. 28.571 round the stored intermediate result to the specified three decimal places [SHIFT] [Rnd] 28.571 [.] Ans . (upper display) 14 [=] 399.994 Cancel specification by specifying "Norm" again. [MODE][MODE][MODE][3][1] 399.994 [ON/AC] [1] [2] [3] [STO] [M] [ON/AC] [4] [5] [6] [M+] [ON/AC] [RCL] [M] M M M M M= 123. D 456 456. D _ 0. D M= 579. D Owner's Manual Safety Precautions is displayed as " ". The function or value assigned to the "GRA" mode:- specify measurement in "grads". "G" symbol appears in display window. Display Modes "FIX" mode:- specify number of decimal places. "Fix" symbol appears in display window. "SCI" mode:- specify number of significant digits. "Sci" symbol appears in display window. next key you press will be inserted in the . To exit from the insertion mode, move the cursors, or press [SHIFT] [INS] , or press [=]. Even after the [=] key has been pressed to calculate a result, it is possible to use this procedure for correction. Press the [3] key to move the cursor to the place where the correction is to be made. Please read before using. – 4 – – 8 – – 12 – – 16 – Arithmetic Operations & Parenthesis Calculations "NORM" mode:- cancels "Fix" and "Sci" specifications. Special Functions Specifying the Number of Significant Digits Be sure to read the following safety precautions before u...