Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Casio, modell fx-82SX

Hersteller: Casio
Dateigröße: 407.68 kb
Dateiname:

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


2 Modes ... 3 Basic Calculations ... 5 Constant Calculations ... 6 Memory Calculations ... 7 Fraction Calculations ... 8 Percentage Calculations ... 10 Scientific Function Calculations ... 11 Statistical Calculations (SD Mode) ... 16 Technical Information ... 18 - 1 - Handling Precautions • Your calculator is made up of precision components. Never try to take it apart. • Avoid dropping your calculator and otherwise subjecting it to strong impact. • Do not store the calculator or leave it in areas exposed to high temperature or humidity, or large amounts of dust. When exposed to low temperature, the calculator may require more time to display results and may even fail to operate. Correct operation will resume once the calculator is brought back to normal temperature. • The display will go blank and keys will not operate during calculations. When you are operating the keyboard, be sure to watch the display to make sure that all your key operations are being performed correctly. • Never leave dead batteries in the battery compartment. They can leak and damage the unit. • Avoid using volatile liquids such as thinner or benzine to clean the unit. Wipe it with a soft cloth, or with a cloth that has been dipped in a solution of water and a neutral detergent and wring out. • In no event will the manufacturer and its suppliers be liable to you or any other person for any damages, expenses, lost profits, lost savings, or any other damages arising out of malfunction, repairs, or battery replacement. The user should prepare physical records of data to protect against such data loss. • Never dispose of batteries, the liquid crystal panel, or other components by burning them. - 2 - • Before assuming malfunction of the unit, be sure to carefully reread this manual and ensure that the problem is not due to low battery power or operational error. • The contents of this manual are subject to change without notice. • No part of this manual may be reproduced in any form without the express written consent of the manufacturer. • Keep this manual on hand for future reference. Modes Application Key Operation Mode Name* Standard deviation calculations |mope|I* 1 SD Normal calculations |mope|IQ 1 COMP Calculations using degrees |mope||4 | DEG Calculations using radians RAD Calculations using grads GRA Number of decimal place specification FIX Number of significant digit specification SCI Cancels FIX and SCI settings |mope||9 1 NORM * Display indicators show current mode setting. Absence of display indicator indicates COMP Mode. - 3 - Note! • A mode guide is located above the display screen. • DEG, RAD, and GRA modes can be used in combination with the COMP and SD modes. • HEdoes not exit SD mode. • Hfflexits SD mode. • Hffldoes not clear SCI or FIX specifications. • Always press T before entering DEG, RAD, and GRA modes. • Remember to always set the operating mode and angular unit (DEG, RAD, GRA) before starting your calculation. - 4 - Basic Calculations • Use the COMP mode for basic calculations. • Example 1: 23+4.5-53 23 □ 4.5 B 53 B • Example 2: 56x(-12)+(-2.5) 56 a 12 E B 2.5 e b • Example 3: 2+3x(1 x1020) 2 B 3 —1 E 20 B • Example 4: 7x8-4x5=36 • Example 5: "4x5 =0.3 4 a 5 b 6 a n b • Example 6: 2x[7+6x(5+4)]=122 2 a e 7 b 6 a E 5 B 4 E E B • You can skip all E operations before -25.5 268.8 6.66666666719 36. 0.3 _122. the B key. - 5 - Constant Calculations • Press O. B. O,or B twice after inputting a number to make that number a constant. • “K” is on the display while a constant is being used. • Use the COMP mode for constant calculations. • Example 1: 2.3+3, then 2.3+6 (2.3+3) 2.3 O O 3 B CO 10 * (2.3+6) 6 B I co CO * • Example 2: 12x2.3, then 12x(-9) (12x2.3) 12 O O 2.3 B I K 27.6 | (12x(-9)) 9 E B | K -108. | • Example 3: 17 + 17+17 + 17=68 (17+17) 17 O O B K 34. I (17+17+17) B K 51. | (17+17+17+17) B 8. 6 * • Example 4: 1.74=8.3521 (1.72) u B O O .7 K 2.89 | (1.73) B K 4.913 | (1.74) B - 6 - K 8.3521 | Memory Calculations • Use the COMP mode for memory calculations. • Use Y, E, A B and Z for memory calculations. Y replaces current memory contents. • “M” appears when there is a value in memory. • To clear memory, press IO Y or T Y. • Example 1 ck C* T X CD J-0 T co 1 CO T CD + CO -4)= 5 .7 O c\l (53+6) 53 □ 6 B Y I M 59. | (23-8) 23 B 8 E 1 M 15. I (56x2) 56 B 2 № I M 112. | (99+4) 99 B 4 E 1 M 24.75 | (Memory recall) z I M 210.75 | Example 2: To calculate the following using memory as shown. 7+ 7-7+ (2x3)+(2x3)-(2x3) =13 I_||_||_||_||_||_||_| l I ll I 11 I ill I I 7 ® H [fflg 203GB(B3SGE(MI 13. M - 7 - • Example 3: To calculate the following using memory and a constant: (12x3)-(45x3)+(78x3)=135. (12x3) 3 O O 12 B YI MK 36. I (45x3) 45 A B | MK 135. | (78x3) 78 E | MK 234. | (Memory recall) IZ |_ Fraction Calculations • Use COMP mode for fraction calculations. • Total number of digits (including division marks) ...

Dieses Handbuch ist für folgende Modelle:
Taschenrechner - 250HC (407.68 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien